Diagnosis and Testing - Body Closures
Diagnostic Trouble Code (DTC) Chart
The diagnosis in this manual assumes a certain level of skill and knowledge of Ford-approved diagnostic procedures.
REFER TO: Diagnostic Methods (100-00 General Information, Description and Operation).
Diagnostic Trouble Code Chart
| Module | Trouble Code | Description | Action |
|---|---|---|---|
| BCM | B11C4:23 | Liftgate/Tailgate Close Switch: Low Signal | GO to Pinpoint Test C |
| BCM | B1219:11 | Interior Liftgate/Tailgate Open Switch: Short to Ground | GO to Pinpoint Test C |
| BCM | B12E8:23 | Liftgate/Tailgate Control/Unlatch Switch: Constantly Low Signal | GO to Pinpoint Test C |
| BCM | B144C: 23 | Rear Door/Liftgate/Tailgate Exterior Handle Switch: Low Signal | GO to Pinpoint Test C |
| BCM | B1495:02 | Liftgate/Tailgate Hands-Free Input Sensor: General Signal Failure | GO to Pinpoint Test J |
| BCM | B1495:08 | Liftgate/Tailgate Hands-Free Input Sensor: Signal/Message Bus Failure | GO to Pinpoint Test J |
| BCM | B1495:11 | Liftgate/Liftglass Ajar Switch: Short to Ground | GO to Pinpoint Test J |
| BCM | B1495:49 | Hands-Free Liftgate/Liftglass Ajar Sensor: Internal Electronic Failure | GO to Pinpoint Test J |
| BCM | B1495:55 | Hands-Free Liftgate/Liftglass Ajar Sensor: Not Configured | GO to Pinpoint Test P |
| RKE | B12E8:11 | Liftgate/Liftglass Unlatch Button Switch: Short to Ground | GO to Pinpoint Test C |
| RKE | B144D: 29 | Liftgate/Liftglass/Tailgate/Trunk Position Sensor 1: Invalid Signal | GO to Pinpoint Test B |
| RKE | B144E:29 | Liftgate/Liftglass/Tailgate/Trunk Position Sensor 2: Invalid Signal | GO to Pinpoint Test B |
| RKE | B144F:11 | Liftgate/Liftglass/Tailgate/Trunk Motor: Short to Ground | GO to Pinpoint Test B |
| RKE | B144F:12 | Liftgate/Liftglass/Tailgate/Trunk Motor: Short to Battery | GO to Pinpoint Test B |
| RKE | B144F:13 | Liftgate/Liftglass/Tailgate/Trunk Power Actuator Motor: Open Circuit | GO to Pinpoint Test B |
| RKE | B144F: 79 | Liftgate/Liftglass/Tailgate/Trunk Power Actuator Motor: Mechanical Linkage Malfunction | GO to Pinpoint Test B |
| RKE | B1451:29 | Liftgate/Liftglass/Tailgate/Trunk Lock Center Position Switch: Invalid Signal | GO to Pinpoint Test D |
| RKE | B1452:11 | Liftgate/Liftglass/Tailgate/Trunk Lock Actuator: Short to Ground | GO to Pinpoint Test A |
| RKE | B1452:13 | Liftgate/Liftglass/Tailgate/Trunk Lock Actuator: Circuit Open | GO to Pinpoint Test A |
| RKE | B1453:29 | Liftgate/Liftglass/Tailgate/Trunk Latch Position Switch: Invalid Signal | GO to Pinpoint Test D |
| RKE | B1454:11 | Liftgate/Liftglass/Tailgate/Trunk Left Striker: Circuit Short to Ground | GO to Pinpoint Test G |
| RKE | B1454:13 | Liftgate/Liftglass/Tailgate/Trunk Left Striker: Circuit Open | GO to Pinpoint Test G |
| RKE | B1455:11 | Liftgate/Liftglass/Tailgate/Trunk Right Striker: Circuit Short to Ground | GO to Pinpoint Test G |
| RKE | B1455:13 | Liftgate/Liftglass/Tailgate/Trunk Right Striker: Circuit Open | GO to Pinpoint Test G |
| RKE | B145D:11 | Liftgate/Liftglass/Tailgate/Trunk Power Cinch Striker Motor: Short to Ground | GO to Pinpoint Test D |
| RKE | B145D:12 | Liftgate/Liftglass/Tailgate/Trunk Power Cinch Striker Motor: Short to Battery | GO to Pinpoint Test D |
| RKE | B145D:13 | Liftgate/Liftglass/Tailgate/Trunk Power Cinch Striker Motor: Circuit Open | GO to Pinpoint Test D |
| RKE | B1515:77 | Liftgate/Liftglass/Tailgate/Trunk: Commanded Position Not Available | GO to Pinpoint Test B |
| RKE | B1515:97 | Liftgate/Liftglass/Tailgate/Trunk: Component or System Operation Obstructed or Stuck | GO to Pinpoint Test B |
| RKE | B1555:29 | Liftgate/Liftglass/Tailgate/Trunk Position Sensor 4: Invalid Signal | GO to Pinpoint Test B |
| RKE | B1556:29 | Liftgate/Liftglass/Tailgate/Trunk Position Sensor 3: Invalid Signal | GO to Pinpoint Test B |
| RKE | B1557:11 | Liftgate/Liftglass Power Actuator 2 Motor: Short to Ground | GO to Pinpoint Test B |
| RKE | B1557:12 | Liftgate/Liftglass Power Actuator 2 Motor: Short to Battery | GO to Pinpoint Test B |
| RKE | B1557:13 | Liftgate/Liftglass Power Actuator 2 Motor: Circuit Open | GO to Pinpoint Test B |
| RKE | C1B14:11 | Sensor Supply Voltage A: Circuit Short to Ground | GO to Pinpoint Test B |
| RKE | C1B15:11 | Sensor Supply Voltage B: Circuit Short to Ground | GO to Pinpoint Test B |
| RKE | P0A2F: 4B | Power Actuator "A" Overtemperature: Overtemperature | GO to Pinpoint Test B |
| RKE | P0A35:4B | Power Actuator "B" Overtemperature: Overtemperature | GO to Pinpoint Test B |
| RKE | U0101:87 | Lost Communication with TCM: No Sub Type Information | GO to Pinpoint Test K |
| RKE | U0140:87 | Lost Communication with Body Control Module: No Sub Type Information | GO to Pinpoint Test L |
| RKE | U0294:87 | Lost Communication with Powertrain Control Module Monitor: No Sub Type Information | GO to Pinpoint Test M |
| RKE | U201A: 55 | Control Module Primary Calibration Data: Not Configured | GO to Pinpoint Test Q |
| RKE | U2300:56 | Central Configuration: Incorrect/Incompatible Configuration | GO to Pinpoint Test Q |
| RKE | U3000:49 | Control Module: Internal Electronic Failure | GO to Pinpoint Test Q |
| RKE | U3003:16 | Battery Voltage: Circuit Voltage Below Threshold | GO to Pinpoint Test N |
| RKE | U3003:17 | Battery Voltage: Circuit Voltage Above Threshold | GO TO Pinpoint Test O |
Global Customer Symptom Codes (GCSC) Table
The diagnosis in this manual assumes a certain level of skill and knowledge of Ford-approved diagnostic procedures.
REFER TO: Diagnostic Methods (100-00 General Information, Description and Operation).
| Symptom | Action |
|---|---|
| Fit and Finish/Body > Body Panels > Liftgate/Liftglass > Alignment | GO TO Pinpoint Test R |
| Fit and Finish/Body > Body Panels > Liftgate/Liftglass > Alignment | GO to Pinpoint Test S |
| Fit and Finish/Body > Body Panels > Liftgate/Liftglass > Alignment | GO TO Pinpoint Test T |
| Fit and Finish/Body > Body Panels > Liftgate/Liftglass > Hard to Close | GO to Pinpoint Test G |
| Fit and Finish/Body > Body Panels > Liftgate/Liftglass > Hard to Open | GO to Pinpoint Test A |
| Fit and Finish/Body > Body Panels > Liftgate/Liftglass > Poor Fit | GO TO Pinpoint Test R |
| Fit and Finish/Body > Body Panels > Liftgate/Liftglass > Poor Fit | GO TO Pinpoint Test T |
| Fit and Finish/Body > Body Panels > Liftgate/Liftglass > Power Control | GO to Pinpoint Test B |
| Fit and Finish/Body > Body Panels > Liftgate/Liftglass > Power Control | GO to Pinpoint Test C |
| Fit and Finish/Body > Body Panels > Liftgate/Liftglass > Power Function | GO to Pinpoint Test B |
| Fit and Finish/Body > Body Panels > Liftgate/Liftglass > Power Function | GO to Pinpoint Test D |
| Fit and Finish/Body > Body Panels > Liftgate/Liftglass > Power Function | GO to Pinpoint Test F |
| Fit and Finish/Body > Body Panels > Liftgate/Liftglass > Power Function | GO to Pinpoint Test G |
| Secure and Reliable > Locks/Latches > Liftgate/Liftglass > Hard to Open | GO to Pinpoint Test A |
| Secure and Reliable > Locks/Latches > Liftgate/Liftglass > Sticks/Binds | GO TO Pinpoint Test R |
| Secure and Reliable > Locks/Latches > Liftgate/Liftglass > Sticks/Binds | GO TO Pinpoint Test T |
| Secure and Reliable > Remote Entry > Control > Inoperative | GO to Pinpoint Test C |
| Secure and Reliable > Handle/Lever > Liftgate/Liftglass > Hard to Close | GO to Pinpoint Test G |
Symptom Chart
Symptom Chart: Power Liftgate
The diagnosis in this manual assumes a certain level of skill and knowledge of Ford-approved diagnostic procedures.
REFER TO: Diagnostic Methods (100-00 General Information, Description and Operation).
| Condition | Action |
|---|---|
| Power Liftgate Inoperative from RKE Transmitter |
|
| Power Liftgate Passive Entry Function Inoperative. |
|
| Power Liftgate Does Not Open |
|
| Liftgate Opens But Power Liftgate Inoperative |
|
| Power Liftgate Inoperative from One of the Power Liftgate Control Switches |
|
| Power Liftgate Stops at Second Latch Position. |
|
| Power Liftgate Stops During Power Opening | GO TO Pinpoint Test R |
| Power Liftgate Stops and Chimes at Fully Open Position | GO to Pinpoint Test S |
| Power Liftgate Reverses During Power Closing |
|
| Liftgate Pinch Strip Does Not Stop or Reverse the Liftgate. |
|
| Power Liftgate Does Not Close (Opens Normally) |
|
| Power Liftgate Does Not Open (Closes Normally) |
|
| Power Liftgate Closes (With Continuous Chime) Immediately After Power Opening. |
|
| Power liftgate does not operate hands-free |
|
| Power liftgate makes excessive noise during operation | GO TO Pinpoint Test T |
Pinpoint Tests
PINPOINT TEST A: POWER LIFTGATE DOES NOT RESPOND Refer to Wiring Diagrams Cell 109 for schematic and connector information. Normal Operation and Fault SymptomsRefer to: Body Locks and Latches - System Operation and Component Description (501-03 Body Locks and Latches, Description and Operation). DTC Fault Trigger Conditions
Possible Sources
Visual Inspection and Pre-checks
NOTICE: Use the correct probe adapter(s) when making measurements. Using incorrect probe adapter(s) may damage the connector. NOTICE: The following Pinpoint Test uses a test lamp to simulate normal circuit loads. Use only the Rotunda test lamp (SGT27000) or a 300 mA incandescent bulb. To avoid damage to connector terminals, use the Rotunda Flex Probe Kit to connect the test lamp probe to the vehicle. Do not use the test lamp probe directly on any connector. |
||||||||||
| A1 CHECK THE RGTM (REAR GATE TAILGATE MODULE) PID (PARAMETER IDENTIFICATION) | ||||||||||
Do the PIDs match the liftgate latch status?
|
||||||||||
| A2 CHECK THE BATTERY VOLTAGE SUPPLY TO THE LIFTGATE LATCH | ||||||||||
Do the PIDs match the liftgate latch status?
|
||||||||||
| A3 CHECK THE LIFTGATE LATCH MANUAL UNLOCK | ||||||||||
Does the liftgate latch open?
|
||||||||||
| A4 CHECK THE RGTM (REAR GATE TAILGATE MODULE) HIGH CURRENT VOLTAGE | ||||||||||
Does the test lamp illuminate?
|
||||||||||
| A5 CHECK THE RGTM (REAR GATE TAILGATE MODULE) HIGH CURRENT VOLTAGE SUPPLY CIRCUIT FOR AN OPEN | ||||||||||
Is the resistance less than 3 ohms?
|
||||||||||
| A6 CHECK THE VOLTAGE AT THE POWER LIFTGATE LATCH MOTOR | ||||||||||
Does the test lamp illuminate momentarily?
|
||||||||||
| A7 CHECK THE POWER LIFTGATE LATCH GROUND CIRCUIT FOR AN OPEN | ||||||||||
Does the test lamp illuminate momentarily?
|
||||||||||
| A8 CHECK THE RGTM (REAR GATE TAILGATE MODULE) FOR A SHORT TO GROUND IN THE LIFTGATE LATCH UNLOCK OUTPUT CIRCUIT | ||||||||||
Is the resistance greater than 10000 Ohms?
|
||||||||||
| A9 CHECK THE RGTM (REAR GATE TAILGATE MODULE) LIFTGATE LATCH UNLOCK OUTPUT CIRCUIT FOR AN OPEN | ||||||||||
Is the resistance less than 3 ohms?
|
||||||||||
| A10 CHECK THE RGTM (REAR GATE TAILGATE MODULE) FOR PROPER OPERATION | ||||||||||
Is the concern still present?
|
PINPOINT TEST B: POWER LIFTGATE UNLATCHES BUT POWER LIFTGATE DOES NOT OPERATE Refer to Wiring Diagrams Cell 109 for schematic and connector information. Normal Operation and Fault SymptomsRefer to: Body Locks and Latches - System Operation and Component Description (501-03 Body Locks and Latches, Description and Operation). DTC Fault Trigger Conditions
Possible Sources
NOTICE: Use the correct probe adapter(s) when making measurements. Using incorrect probe adapter(s) may damage the connector. |
||||||||||||||||||||||||||||||||||||||||||||||||||||||
| B1 CHECK THE COMMUNICATION WITH THE RGTM (REAR LIFTGATE MODULE) | ||||||||||||||||||||||||||||||||||||||||||||||||||||||
Does the RGTM pass the network test?
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||
| B2 CHECK THE RGTM (REAR LIFTGATE MODULE) PID (PARAMETER IDENTIFICATION) | ||||||||||||||||||||||||||||||||||||||||||||||||||||||
Do the PIDs match the liftgate latch status?
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||
| B3 CHECK THE POWER LIFTGATE STRUT POSITION SENSOR | ||||||||||||||||||||||||||||||||||||||||||||||||||||||
Do the parameter identifications (PIDs) match the rear liftgate position sensor status?
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||
| B4 CHECK THE BATTERY VOLTAGE SUPPLY TO THE LIFTGATE LATCH | ||||||||||||||||||||||||||||||||||||||||||||||||||||||
Do the PIDs match the liftgate latch status?
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||
| B5 CHECK THE LIFTGATE LATCH PRIMARY AND SECONDARY SWITCH PARAMETER IDENTIFICATIONS (PIDS) | ||||||||||||||||||||||||||||||||||||||||||||||||||||||
Do the switch states match the table?
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||
| B6 CHECK THE OPERATION OF ALL POWER LIFTGATE INPUTS | ||||||||||||||||||||||||||||||||||||||||||||||||||||||
Does the power liftgate open or close from any input?
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||
| B7 CHECK THE RGTM (REAR LIFTGATE MODULE) COMMUNICATION AND VOLTAGE DIAGNOSTIC TROUBLE CODES (DTCS) | ||||||||||||||||||||||||||||||||||||||||||||||||||||||
Is DTC U0101:87, U0140:87, U0294:87, U3003:16 or U3003:17 present?
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||
| B8 CHECK THE POWER LIFTGATE MOTOR DIAGNOSTIC TROUBLE CODES (DTCS) | ||||||||||||||||||||||||||||||||||||||||||||||||||||||
Is DTC B144F:11, B144F:12, B144F:13, B144F:79, B1557:11, B1557:12, B1557:13, B1515:77 or B1515:97 present?
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||
| B9 CHECK THE POWER LIFTGATE MOTOR CIRCUITS FOR A SHORT TO VOLTAGE | ||||||||||||||||||||||||||||||||||||||||||||||||||||||
Is there voltage present?
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||
| B10 CHECK THE POWER LIFTGATE MOTOR CIRCUITS FOR A SHORT TO GROUND | ||||||||||||||||||||||||||||||||||||||||||||||||||||||
Is the resistance greater than 10000 ohms?
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||
| B11 CHECK THE POWER LIFTGATE MOTOR CIRCUITS FOR A SHORT TOGETHER | ||||||||||||||||||||||||||||||||||||||||||||||||||||||
Is the resistance greater than 10000 Ohms?
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||
| B12 CHECK THE POWER LIFTGATE ACTUATOR CIRCUITS FOR AN OPEN | ||||||||||||||||||||||||||||||||||||||||||||||||||||||
Is the resistance less than 3 ohms?
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||
| B13 CHECK THE POWER LIFTGATE LATCH ACTUATOR DIAGNOSTIC TROUBLE CODES (DTCS) | ||||||||||||||||||||||||||||||||||||||||||||||||||||||
Are DTC B144D:29, B144E:29, B1555:29 or B1556:29 present?
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||
| B14 CHECK THE POWER LIFTGATE LATCH ACTUATOR CIRCUITS FOR A SHORT TO VOLTAGE | ||||||||||||||||||||||||||||||||||||||||||||||||||||||
Is there voltage present?
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||
| B15 CHECK THE POWER LIFTGATE LATCH ACTUATOR CIRCUITS FOR A SHORT TO GROUND | ||||||||||||||||||||||||||||||||||||||||||||||||||||||
Is the resistance greater than 10000 ohms?
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||
| B16 CHECK THE POWER LIFTGATE LATCH ACTUATOR CIRCUITS FOR A SHORT | ||||||||||||||||||||||||||||||||||||||||||||||||||||||
Is the resistance greater than 10000 ohms?
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||
| B17 CHECK THE POWER LIFTGATE LATCH ACTUATOR CIRCUITS FOR AN OPEN | ||||||||||||||||||||||||||||||||||||||||||||||||||||||
Is the resistance less than 3 ohms?
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||
| B18 CHECK THE OTHER POWER LIFTGATE LATCH DIAGNOSTIC TROUBLE CODES (DTCS) | ||||||||||||||||||||||||||||||||||||||||||||||||||||||
Are any RGTM diagnostic trouble codes (DTCs) present?
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||
| B19 CHECK THE RGTM (REAR GATE TAILGATE MODULE) FOR NORMAL OPERATION | ||||||||||||||||||||||||||||||||||||||||||||||||||||||
Is the concern still present?
|
PINPOINT TEST C: POWER LIFTGATE DOES NOT OPERATE DUE TO ONE OF THE POWER LIFTGATE CONTROL SWITCHES Refer to Wiring Diagrams Cell 109 for schematic and connector information. Normal Operation and Fault SymptomsRefer to: Body Locks and Latches - System Operation and Component Description (501-03 Body Locks and Latches, Description and Operation). DTC Fault Trigger Conditions
Possible Sources
NOTICE: Use the correct probe adapter(s) when making measurements. Using incorrect probe adapter(s) may damage the connector. |
||||||||||||||||||||||
| C1 CHECK THE POWER LIFTGATE LATCH POSITION SENSOR | ||||||||||||||||||||||
Do the parameter identifications (PIDs) match the rear liftgate position sensor status?
|
||||||||||||||||||||||
| C2 CHECK THE BATTERY VOLTAGE SUPPLY TO THE LIFTGATE LATCH | ||||||||||||||||||||||
Do the PIDs match the liftgate latch status?
|
||||||||||||||||||||||
| C3 CHECK THE POWER LIFTGATE OPERATION FROM ALL SWITCH INPUTS | ||||||||||||||||||||||
Does the power liftgate open or close from any input?
|
||||||||||||||||||||||
| C4 CHECK THE POWER LIFTGATE SWITCH STATUS | ||||||||||||||||||||||
Do the Parameter Identifications (PIDs) indicate that the switch is pressed?
|
||||||||||||||||||||||
| C5 ISOLATE THE SUSPECT POWER LIFTGATE SWITCH FROM A SHORT TO GROUND (PARAMETER IDENTIFICATION) | ||||||||||||||||||||||
Does the PID in question continue to indicate that the switch is pressed?
|
||||||||||||||||||||||
| C6 ISOLATE THE BCM (BODY CONTROL MODULE) SHORT WHEN CHECKING THE RGTM (REAR GATE TAILGATE MODULE) LFTGATE_R_SW() PID (PARAMETER IDENTIFICATION) | ||||||||||||||||||||||
Does the PID continue to indicate that the switch is pressed?
|
||||||||||||||||||||||
| C7 CHECK THE POWER LIFTGATE SWITCH INPUT CIRCUIT FOR A SHORT TO GROUND | ||||||||||||||||||||||
Is the resistance greater than 10000 Ohms?
|
||||||||||||||||||||||
| C8 BYPASS THE SUSPECT POWER LIFTGATE SWITCH | ||||||||||||||||||||||
Does the liftgate open or close?
|
||||||||||||||||||||||
| C9 CHECK THE POWER LIFTGATE SWITCH POWER SUPPLY CIRCUIT FOR AN OPEN | ||||||||||||||||||||||
Does the liftgate open or close?
|
||||||||||||||||||||||
| C10 CHECK THE POWER LIFTGATE SWITCH INPUT CIRCUIT FOR AN OPEN | ||||||||||||||||||||||
Is the resistance less than 3 ohms?
|
||||||||||||||||||||||
| C11 CHECK THE BCM (BODY CONTROL MODULE) FOR NORMAL OPERATION | ||||||||||||||||||||||
Is the concern still present?
|
||||||||||||||||||||||
| C12 CHECK RGTM (POWER LIFTGATE MODULE) OPERATION | ||||||||||||||||||||||
Is the concern still present?
|
PINPOINT TEST D: POWER LIFTGATE STOPS IN SECONDARY LATCH POSITION Normal Operation and Fault SymptomsRefer to: Body Locks and Latches - System Operation and Component Description (501-03 Body Locks and Latches, Description and Operation). DTC Fault Trigger Conditions
Possible Sources
|
||||||||||||||||||||||||
| D1 CHECK RGTM (POWER LIFTGATE MODULE) PID (PARAMETER IDENTIFICATION) | ||||||||||||||||||||||||
Do the PIDs match the liftgate latch status?
|
||||||||||||||||||||||||
| D2 CHECK POWER LIFTGATE ACTUATOR POSITION SENSOR | ||||||||||||||||||||||||
Do the parameter identifications (PIDs) match the rear liftgate position sensor status?
|
||||||||||||||||||||||||
| D3 CHECK BATTERY VOLTAGE SUPPLY TO THE POWER LIFTGATE LATCH | ||||||||||||||||||||||||
Do the PIDs match the liftgate latch status?
|
||||||||||||||||||||||||
| D4 CHECK POWER LIFTGATE SELF-TEST LEARN STATUS | ||||||||||||||||||||||||
Has the power liftgate return learn been completed?
|
||||||||||||||||||||||||
| D5 CHECK PRIMARY AND SECONDARY LIFTGATE LATCH AND LATCH SWITCH PARAMETER IDENTIFICATION (PIDS) | ||||||||||||||||||||||||
Do the switch states match the table?
|
||||||||||||||||||||||||
| D6 CHECK POWER LIFTGATE MANUAL OPERATION | ||||||||||||||||||||||||
Does the liftgate open and close correctly?
|
||||||||||||||||||||||||
| D7 CHECK LIFTGATE LATCH AND STRIKER | ||||||||||||||||||||||||
Are the latch and striker correctly aligned?
|
||||||||||||||||||||||||
| D8 CHECK POWER LIFTGATE LATCH INPUT CIRCUITS FOR A SHORT TO GROUND | ||||||||||||||||||||||||
Is the resistance greater than 10000 ohms?
|
||||||||||||||||||||||||
| D9 CHECK POWER LIFTGATE LATCH INPUT CIRCUITS FOR A SHORT TO EACH OTHER | ||||||||||||||||||||||||
Is the resistance greater than 10000 ohms?
|
||||||||||||||||||||||||
| D10 CHECK POWER LIFTGATE LATCH INPUT CIRCUITS FOR AN OPEN CIRCUIT | ||||||||||||||||||||||||
Is the resistance less than 3 ohms?
|
||||||||||||||||||||||||
| D11 CHECK POWER LIFTGATE LATCH MOTOR CIRCUITS FOR A SHORT TO VOLTAGE | ||||||||||||||||||||||||
Is there voltage present?
|
||||||||||||||||||||||||
| D12 CHECK POWER LIFTGATE LATCH MOTOR CIRCUITS FOR A SHORT TO GROUND | ||||||||||||||||||||||||
Is the resistance greater than 10000 ohms?
|
||||||||||||||||||||||||
| D13 CHECK POWER LIFTGATE LATCH MOTOR CIRCUITS FOR A SHORT | ||||||||||||||||||||||||
Is the resistance greater than 10000 Ohms?
|
||||||||||||||||||||||||
| D14 CHECK POWER LIFTGATE LATCH MOTOR CIRCUITS FOR AN OPEN CIRCUIT | ||||||||||||||||||||||||
Is the resistance less than 3 ohms?
|
||||||||||||||||||||||||
| D15 CHECK POWER LIFTGATE LATCH MOTOR CIRCUITS FOR A SHORT TO THE SECTOR GEAR SWITCH INPUT CIRCUIT | ||||||||||||||||||||||||
Is the resistance greater than 10000 ohms?
|
||||||||||||||||||||||||
| D16 CHECK SECTOR GEAR SWITCH INPUT CIRCUIT FOR AN OPEN CIRCUIT | ||||||||||||||||||||||||
Is the resistance less than 3 ohms?
|
||||||||||||||||||||||||
| D17 CHECK RGTM (POWER LIFTGATE MODULE) OPERATION | ||||||||||||||||||||||||
Is the concern still present?
|
PINPOINT TEST E: POWER LIFTGATE REVERSES DURING POWER CLOSING OPERATION Normal Operation and Fault SymptomsRefer to: Body Locks and Latches - System Operation and Component Description (501-03 Body Locks and Latches, Description and Operation). Possible Sources
Visual Inspection and Pre-checks
|
||||||||||||||||||||||||
| E1 CHECK POWER LIFTGATE POSITION SENSOR | ||||||||||||||||||||||||
Do the parameter identifications (PIDs) match the rear liftgate position sensor status?
|
||||||||||||||||||||||||
| E2 CHECK BATTERY VOLTAGE SUPPLY TO THE POWER LIFTGATE LATCH | ||||||||||||||||||||||||
Do the PIDs match the liftgate latch status?
|
||||||||||||||||||||||||
| E3 CHECK ANTI-PINCH SWITCH STATUS | ||||||||||||||||||||||||
Does the anti-pinch strip activate during closing?
|
||||||||||||||||||||||||
| E4 CHECK PRIMARY AND SECONDARY LIFTGATE LATCH AND LATCH SWITCH PARAMETER IDENTIFICATION (PIDS) | ||||||||||||||||||||||||
Do the switch states match the table?
|
||||||||||||||||||||||||
| E5 CHECK POWER LIFTGATE MANUAL OPERATION | ||||||||||||||||||||||||
Does the liftgate open and close correctly?
|
PINPOINT TEST F: POWER LIFTGATE PINCH STRIP DOES NOT STOP OR REVERSE POWER LIFTGATE Refer to Wiring Diagrams Cell 109 for schematic and connector information. Normal Operation and Fault SymptomsRefer to: Body Locks and Latches - System Operation and Component Description (501-03 Body Locks and Latches, Description and Operation). Possible Sources
NOTICE: Use the correct probe adapter(s) when making measurements. Using incorrect probe adapter(s) may damage the connector. |
|||||||||||||
| F1 CHECK BATTERY VOLTAGE SUPPLY TO THE POWER LIFTGATE LATCH | |||||||||||||
Do the PIDs match the liftgate latch status?
|
|||||||||||||
| F2 CHECK ANTI-PINCH SWITCH STATUS | |||||||||||||
Does the anti-pinch strip activate during closing?
|
|||||||||||||
| F3 CHECK ANTI-PINCH VOLTAGE | |||||||||||||
Is the voltage above 6V?
|
|||||||||||||
| F4 CHECK RGTM (POWER LIFTGATE MODULE) DIAGNOSTIC TROUBLE CODES (DTCS) | |||||||||||||
Are any diagnostic trouble codes (DTCs) present?
|
|||||||||||||
| F5 CHECK POWER LIFTGATE ANTI-PINCH SWITCH | |||||||||||||
Is the resistance between 0 and 200 ohms with the liftgate anti-pinch switch fully pressed, and between 5700 and 6700 ohms with the liftgate anti-pinch switch released?
|
|||||||||||||
| F6 CHECK RGTM (REAR GATE TAILGATE MODULE) OPERATION | |||||||||||||
Is the concern still present?
|
PINPOINT TEST G: POWER LIFTGATE DOES NOT CLOSE (POWER OPEN OK) Refer to Wiring Diagrams Cell 109 for schematic and connector information. Normal Operation and Fault SymptomsRefer to: Body Locks and Latches - System Operation and Component Description (501-03 Body Locks and Latches, Description and Operation). DTC Fault Trigger Conditions
Possible Sources
NOTICE: Use the correct probe adapter(s) when making measurements. Using incorrect probe adapter(s) may damage the connector. NOTICE: Use the correct probe adapter(s) when making measurements. Using incorrect probe adapter(s) may damage the connector. |
||||||||||||||||||||||
| G1 CHECK BATTERY VOLTAGE SUPPLY TO REAR LIFTGATE LATCH | ||||||||||||||||||||||
Do the PIDs match the liftgate latch status?
|
||||||||||||||||||||||
| G2 CHECK POWER LIFTGATE SELF-TEST LEARN STATUS | ||||||||||||||||||||||
Has the power liftgate return learn been completed?
|
||||||||||||||||||||||
| G3 CHECK POWER REAR LIFTGATE STRUT POSITION SENSOR | ||||||||||||||||||||||
Do the parameter identifications (PIDs) match the rear liftgate position sensor status?
|
||||||||||||||||||||||
| G4 CHECK ANTI-PINCH SWITCH STATUS | ||||||||||||||||||||||
Does the anti-pinch strip activate during closing?
|
||||||||||||||||||||||
| G5 CHECK ANTI-PINCH VOLTAGE | ||||||||||||||||||||||
Is the voltage above 6V?
|
||||||||||||||||||||||
| G6 CHECK RGTM (REAR GATE TAILGATE MODULE) LIFTGATE SWITCH DIAGNOSTIC TROUBLE CODES (DTCS) | ||||||||||||||||||||||
Is DTC B1454:11, B1454:13, B1455:11 or B1455:13 present?
|
||||||||||||||||||||||
| G7 CHECK LIFTGATE ANTI-PINCH SWITCH | ||||||||||||||||||||||
Is the resistance between 0 and 200 ohms with the liftgate anti-pinch switch fully pressed, and between 5700 and 6700 ohms with the liftgate anti-pinch switch released?
|
||||||||||||||||||||||
| G8 CHECK LIFTGATE ANTI-PINCH SWITCH CIRCUITS FOR SHORT TO VOLTAGE | ||||||||||||||||||||||
Is there voltage present?
|
||||||||||||||||||||||
| G9 CHECK LIFTGATE ANTI-PINCH SWITCH CIRCUITS FOR SHORT TO GROUND | ||||||||||||||||||||||
Is the resistance greater than 10000 Ohms?
|
||||||||||||||||||||||
| G10 CHECK LIFTGATE ANTI-PINCH PREVENTION CIRCUITS FOR SHORT TO GROUND TOGETHER | ||||||||||||||||||||||
Is the resistance greater than 10000 Ohms?
|
||||||||||||||||||||||
| G11 CHECK LIFTGATE ANTI-PINCH SWITCH CIRCUITS FOR OPEN | ||||||||||||||||||||||
Is the resistance less than 3 ohms?
|
||||||||||||||||||||||
| G12 CHECK OTHER RGTM (REAR GATE TAILGATE MODULE) DIAGNOSTIC TROUBLE CODES (DTCS) | ||||||||||||||||||||||
Are any diagnostic trouble codes (DTCs) present?
|
||||||||||||||||||||||
| G13 CHECK LIFTGATE MANUAL OPERATION OF POWER LIFTGATE SUPPORT | ||||||||||||||||||||||
Does the liftgate open and close correctly?
|
||||||||||||||||||||||
| G14 CHECK RGTM (REAR GATE TAILGATE MODULE) OPERATION | ||||||||||||||||||||||
Is the concern still present?
|
PINPOINT TEST H: POWER LIFTGATE DOES NOT OPEN (POWER CLOSE OK) Normal Operation and Fault SymptomsRefer to: Body Locks and Latches - System Operation and Component Description (501-03 Body Locks and Latches, Description and Operation). Possible Sources
|
||||||||||||||||||||||||
| H1 CHECK LIFTGATE LATCH PRIMARY AND SECONDARY PARAMETER IDENTIFICATION AND LATCH SWITCH (PIDS) | ||||||||||||||||||||||||
Do the switch states match the table?
|
||||||||||||||||||||||||
| H2 CHECK RGTM (REAR GATE TAILGATE MODULE) PID (PARAMETER IDENTIFICATION) | ||||||||||||||||||||||||
Do the PIDs match the liftgate latch status?
|
||||||||||||||||||||||||
| H3 CHECK POWER REAR LIFTGATE STRUT POSITION SENSOR | ||||||||||||||||||||||||
Do the parameter identifications (PIDs) match the rear liftgate position sensor status?
|
||||||||||||||||||||||||
| H4 CHECK BATTERY VOLTAGE SUPPLY TO REAR LIFTGATE LATCH | ||||||||||||||||||||||||
Do the PIDs match the liftgate latch status?
|
||||||||||||||||||||||||
| H5 CHECK RGTM (REAR GATE TAILGATE MODULE) DIAGNOSTIC TROUBLE CODES (DTCS) | ||||||||||||||||||||||||
Are any diagnostic trouble codes (DTCs) present?
|
||||||||||||||||||||||||
| H6 CHECK LIFTGATE LATCH RELEASE OPERATION | ||||||||||||||||||||||||
Does the liftgate latch open?
|
||||||||||||||||||||||||
| H7 CHECK LIFTGATE MANUAL OPERATION OF POWER LIFTGATE SUPPORT | ||||||||||||||||||||||||
Does the liftgate open and close correctly?
|
PINPOINT TEST I: POWER LIFTGATE CLOSES (WITH CONTINUOUS CHIME) IMMEDIATELY AFTER POWER OPEN OPERATION Normal Operation and Fault SymptomsRefer to: Body Locks and Latches - System Operation and Component Description (501-03 Body Locks and Latches, Description and Operation). Possible Sources
|
||||
| I1 CHECK POWER REAR GATE POSITION SENSOR | ||||
Do the parameter identifications (PIDs) match the rear liftgate position sensor status?
|
||||
| I2 CHECK BATTERY VOLTAGE SUPPLY TO REAR LIFTGATE LATCH | ||||
Do the PIDs match the liftgate latch status?
|
||||
| I3 CHECK RGTM (REAR GATE TAILGATE MODULE) DIAGNOSTIC TROUBLE CODES (DTCS) | ||||
Are any diagnostic trouble codes (DTCs) present?
|
||||
| I4 CHECK REAR LIFTGATE STRUT SUPPORT | ||||
Does the rear gate strut correctly hold the liftgate in the open position?
|
||||
| I5 INITIALIZE POWER LIFTGATE AND RECHECK OPERATION | ||||
Does the liftgate close with a continuous audible alert immediately after power is applied?
|
||||
| I6 CHECK RGTM (REAR GATE TAILGATE MODULE) OPERATION | ||||
Is the concern still present?
|
PINPOINT TEST J: HANDS-FREE LIFTGATE SYSTEM DOES NOT OPERATE Refer to Wiring Diagrams Cell 109 for schematic and connector information. Normal Operation and Fault SymptomsRefer to: Body Locks and Latches - System Operation and Component Description (501-03 Body Locks and Latches, Description and Operation). DTC Fault Trigger Conditions
Possible Sources
NOTICE: Use the correct probe adapter(s) when making measurements. Using incorrect probe adapter(s) may damage the connector. |
|||||||||||||||
| J1 CHECK THE POWER LIFTGATE LATCH POSITION SENSOR | |||||||||||||||
Do the parameter identifications (PIDs) match the rear liftgate position sensor status?
|
|||||||||||||||
| J2 CHECK THE BATTERY VOLTAGE SUPPLY TO THE POWER LIFTGATE LATCH MODULE | |||||||||||||||
Do the PIDs match the liftgate latch status?
|
|||||||||||||||
| J3 CHECK THE POWER LIFTGATE OPERATION WITH THE EXTERIOR SWITCH | |||||||||||||||
Does the power liftgate open?
|
|||||||||||||||
| J4 CHECK THE LIFTGATE PASSIVE ENTRY OPERATION | |||||||||||||||
Does the power liftgate open?
|
|||||||||||||||
| J5 VERIFY THE CONCERN IS PRESENT | |||||||||||||||
Does the power liftgate open?
|
|||||||||||||||
| J6 CHECK THE POWER LIFTGATE ACTUATOR MODULE POWER SUPPLY CIRCUIT FOR AN OPEN | |||||||||||||||
Is the voltage greater than 11 volts?
|
|||||||||||||||
| J7 CHECK THE POWER LIFTGATE ACTUATOR MODULE GROUND CIRCUIT | |||||||||||||||
Is the voltage greater than 11 volts?
|
|||||||||||||||
| J8 CHECK THE BCM (BODY CONTROL MODULE) INPUT CIRCUIT FOR A SHORT TO GROUND | |||||||||||||||
Is the resistance greater than 10000 Ohms?
|
|||||||||||||||
| J9 CHECK THE BCM (BODY CONTROL MODULE) INPUT CIRCUIT FOR AN OPEN HANDS-FREE | |||||||||||||||
Is the resistance less than 3 ohms?
|
|||||||||||||||
| J10 CHECK THE LIFTGATE HANDS-FREE LOWER SENSOR | |||||||||||||||
Does the hands-free liftgate operation work?
|
|||||||||||||||
| J11 CHECK THE LIFTGATE HANDS-FREE UPPER SENSOR | |||||||||||||||
Does the hands-free liftgate operation work?
|
|||||||||||||||
| J12 CHECK THE BCM (BODY CONTROL MODULE) OPERATION | |||||||||||||||
Is the concern still present?
|
PINPOINT TEST K: U0101:87 Normal Operation and Fault SymptomsThe RGTM and PCM communicate over CAN. Messages are exchanged between the modules to determine that functions are operating. DTC Fault Trigger Conditions
Possible Sources
|
||||||
| K1 VERIFY THE CUSTOMER CONCERN | ||||||
Is the observed symptom present?
|
||||||
| K2 CHECK THE COMMUNICATION NETWORK | ||||||
Does the PCM pass the network test?
|
||||||
| K3 PERFORM THE PCM (POWERTRAIN CONTROL MODULE) SELF-TEST | ||||||
Are there any non-network diagnostic trouble codes (DTCs)?
|
||||||
| K4 RETRIEVE THE RECORDED DIAGNOSTIC TROUBLE CODES (DTCS) FROM THE RGTM (REAR GATE TAILGATE MODULE) SELF-TEST | ||||||
Are there any non-network diagnostic trouble codes (DTCs)?
|
||||||
| K5 RECHECK THE RGTM (REAR GATE TAILGATE MODULE) DIAGNOSTIC TROUBLE CODES (DTCS) | ||||||
Is DTC U0101:87 still present?
|
||||||
| K6 CHECK FOR OTHER CAUSES OF COMMUNICATION NETWORK CONCERNS | ||||||
Is the observed symptom still present?
|
||||||
| K7 CHECK THE PCM (POWERTRAIN CONTROL MODULE) OPERATION | ||||||
Is the concern still present?
|
PINPOINT TEST L: U0140:87 Normal Operation and Fault SymptomsThe RGTM and BCM communicate over CAN. Messages are exchanged between the modules to determine that functions are operating. DTC Fault Trigger Conditions
Possible Sources
|
||||||
| L1 VERIFY THE CUSTOMER CONCERN | ||||||
Is the observed symptom present?
|
||||||
| L2 CHECK THE COMMUNICATION NETWORK | ||||||
Does the BCM pass the network test?
|
||||||
| L3 PERFORM THE BCM (BODY CONTROL MODULE) SELF-TEST | ||||||
Are there any non-network diagnostic trouble codes (DTCs)?
|
||||||
| L4 RETRIEVE STORED DIAGNOSTIC TROUBLE CODES (DTCS) FROM RGTM (REAR GATE TAILGATE MODULE) SELF-TEST | ||||||
Are there any non-network diagnostic trouble codes (DTCs)?
|
||||||
| L5 RECHECK RGTM (REAR GATE TAILGATE MODULE) DIAGNOSTIC TROUBLE CODES (DTCS) | ||||||
IS DTC U0140:87 STILL PRESENT?
|
||||||
| L6 CHECK FOR OTHER CAUSES OF COMMUNICATION NETWORK CONCERNS | ||||||
Is the observed symptom still present?
|
||||||
| L7 CHECK BCM (BODY CONTROL MODULE) OPERATION | ||||||
Is the concern still present?
|
PINPOINT TEST M: U0294:87 Normal Operation and Fault SymptomsThe RGTM and PCM communicate over CAN. Messages are exchanged between the modules to determine that functions are operating. DTC Fault Trigger Conditions
Possible Sources
|
||||||
| M1 CHECK CUSTOMER CONCERN | ||||||
Is the observed symptom present?
|
||||||
| M2 CHECK THE COMMUNICATION NETWORK | ||||||
Does the PCM pass the network test?
|
||||||
| M3 PERFORM PCM (POWERTRAIN CONTROL MODULE) SELF-TEST | ||||||
Are there any non-network diagnostic trouble codes (DTCs)?
|
||||||
| M4 RETRIEVE STORED DIAGNOSTIC TROUBLE CODES (DTCS) FROM RGTM (REAR GATE TAILGATE MODULE) SELF-TEST | ||||||
Are there any non-network diagnostic trouble codes (DTCs)?
|
||||||
| M5 RECHECK RGTM (REAR GATE TAILGATE MODULE) DIAGNOSTIC TROUBLE CODES (DTCS) | ||||||
IS DTC U0294:87 STILL PRESENT?
|
||||||
| M6 CHECK FOR OTHER CAUSES OF COMMUNICATION NETWORK CONCERNS | ||||||
Is the observed symptom still present?
|
||||||
| M7 CHECK PCM (POWERTRAIN CONTROL MODULE) OPERATION | ||||||
Is the concern still present?
|
PINPOINT TEST N: U3003:16 Refer to Wiring Diagrams Cell 109 for schematic and connector information. Normal Operation and Fault SymptomsThe RGTM monitors its high-current power supply circuit. If a fault is detected, the RGTM disables the power liftgate function. DTC Fault Trigger Conditions
Possible Sources
NOTICE: Use the correct probe adapter(s) when making measurements. Using incorrect probe adapter(s) may damage the connector. |
||||||||||
| N1 CHECK BATTERY VOLTAGE SUPPLY TO THE REAR LIFT BOX CONNECTOR | ||||||||||
Do the PIDs match the liftgate latch status?
|
||||||||||
| N2 RECHECK RGTM (REAR GATE TAILGATE MODULE) DIAGNOSTIC TROUBLE CODES (DTCS) | ||||||||||
IS DTC U3003:16 STILL PRESENT?
|
||||||||||
| N3 CHECK CHARGING SYSTEM DIAGNOSTIC TROUBLE CODES (DTCS) STORED IN OTHER MODULES | ||||||||||
Is any other DTC related to the battery or charging system stored in other modules?
|
||||||||||
| N4 CHECK BATTERY CONDITION AND CHARGE | ||||||||||
Is the battery in good condition and fully charged?
|
||||||||||
| N5 CHECK RGTM (REAR GATE TAILGATE MODULE) POWER_SUPPLY_POWER_VBATT (GATE_PWR_V) PID (PARAMETER IDENTIFICATION) | ||||||||||
Is the voltage within 0.2 volts of the recorded battery voltage?
|
||||||||||
| N6 CHECK RGTM (REAR GATE TAILGATE MODULE) POWER SUPPLY CIRCUIT FOR HIGH RESISTANCE | ||||||||||
Is the voltage within 0.2 volts of the recorded battery voltage?
|
||||||||||
| N7 CHECK RGTM (REAR GATE TAILGATE MODULE) GROUND CIRCUIT FOR HIGH RESISTANCE | ||||||||||
Is the resistance less than 3 ohms?
|
||||||||||
| N8 CHECK RGTM (REAR GATE TAILGATE MODULE) OPERATION | ||||||||||
Is the concern still present?
|
PINPOINT TEST O: U3003:17 Refer to Wiring Diagrams Cell 109 for schematic and connector information. Normal Operation and Fault SymptomsThe RGTM monitors its high-current power supply circuit. If a fault is detected, the RGTM disables the power liftgate function. DTC Fault Trigger Conditions
Possible Sources
|
||||||
| O1 CHECK BATTERY VOLTAGE SUPPLY TO THE REAR LIFT BOX CONNECTOR | ||||||
Do the PIDs match the liftgate latch status?
|
||||||
| O2 CHECK FOR HIGH VOLTAGE DIAGNOSTIC TROUBLE CODES (DTCS) STORED IN OTHER MODULES | ||||||
Are any high voltage DTCs stored in other modules?
|
||||||
| O3 CHECK BATTERY VOLTAGE | ||||||
Does the battery voltage rise to 15.5 volts or higher?
|
||||||
| O4 RECHECK FOR DTC U3003:17 | ||||||
IS DTC U3003:17 STILL PRESENT?
|
PINPOINT TEST P: DTC B1495:55 Normal Operation and Fault SymptomsRefer to: Body Locks and Latches - System Operation and Component Description (501-03 Body Locks and Latches, Description and Operation). DTC Fault Trigger Conditions
Possible Sources
|
||||||
| P1 CHECK DTC B1495:55 | ||||||
Is DTC B1495:55 present?
|
PINPOINT TEST Q: DTC U3000:49 OR U201A:55 OR U2300:56 Normal Operation and Fault SymptomsRefer to: Body Locks and Latches - System Operation and Component Description (501-03 Body Locks and Latches, Description and Operation). DTC Fault Trigger Conditions
Possible Sources
|
||||||||||||
| Q1 CHECK FOR DTCS U201A:55 OR U2300:56 | ||||||||||||
Are DTC U3000:49 present?
|
||||||||||||
| Q2 INSTALL THE BCM (BODY CONTROL MODULE) PMI (PROGRAMMABLE MODULE INSTALLATION) | ||||||||||||
Are DTCs U201A:55 OR U2300:56 present?
|
PINPOINT TEST R: POWER LIFTGATE STOPS DURING POWER OPEN OPERATION Possible Sources
|
||||
| R1 MANUALLY OPERATE THE LIFTGATE AND CHECK FOR A MECHANICAL BIND. | ||||
Is a mechanical bind present?
|
PINPOINT TEST S: POWER LIFTGATE STOPS AND CHIMES IN FULLY OPEN POSITION Normal Operation and Fault SymptomsThe power liftgate lost its fully open position due to mechanical repair (hinge adjustment, liftgate latch adjustment, liftgate motor adjusted or repaired). Possible Sources
|
||||
| S1 MANUALLY OPERATE THE LIFTGATE AND CHECK FOR THE STOP DEVICE AND NOISE IN THE FULLY OPEN POSITION. | ||||
Is a concern present?
|
PINPOINT TEST T: DURING OPERATION THE POWER LIFTGATE MAKES EXCESSIVE NOISE Possible Sources
|
||||
| T1 MANUALLY OPERATE THE LIFTGATE AND CHECK FOR EXCESSIVE NOISE DURING OPERATION. | ||||
Is a mechanical bind present?
|
Test yourself
A quick Ford Escape quiz: every answer comes with an explanation and a link to the manual page.
.jpg)
.jpg)
.jpg)
.jpg)
C4172, terminal 1, component side
VIN required to access Guided Routine (PCM)