AUTOMATIC TRANSMISSION SYSTEM

Low Speed Brake Control Solenoid Valve (UD/B_VFS)

5steps
~30min
2/5difficulty
Done 0 of 5

Description and Operation

Description

  • The underdrive brake control solenoid valve (UD/B) is mounted on the valve body.
  • This variable force solenoid valve indirectly regulates the hydraulic pressure inside the underdrive brake.

Specifications

Specifications

Brake/Clutch Control VFS [UD/B] ▷ Control Type: Normally High Type
Control Pressure [kPa (kgf/cm², psi)] 500,14~9,81 (5,1~0,1, 72,54~1,42)
Current Value (mA) 850~50
Internal Resistance (ohm) 5.1

Circuit Diagrams

Wiring Diagram

Repair Procedures

Inspection

  1. Turn the ignition switch to the OFF position.
  2. Disconnect the battery and battery tray. (Refer to Engine Electrical System - "Battery".)
  3. Disconnect the connector (A) from the solenoid valve.
  4. Measure the resistance between the sensor signal terminal and the sensor ground terminal.
  5. Check that the resistance is within specification.

DEPOSIT