AUTOMATIC TRANSMISSION SYSTEM

Line Pressure Control Solenoid Valve

5steps
~30min
2/5difficulty
Done 0 of 5

Description and Operation

Description

  • The line pressure control solenoid valve is mounted on the valve body.
  • This variable force solenoid valve indirectly regulates the hydraulic pressure inside the line pressure circuit.

Specifications

Specifications

Line Pressure VFS Control [LINE Pressure] ▷ Control Type: Normally High Type
Control Pressure [kPa (kgf/cm², psi)] 500,14~9,81 (5,1~0,1, 72,54~1,42)
Current Value (mA) 850~50
Internal Resistance (ohm) 5.1

Circuit Diagrams

Wiring Diagram

Repair Procedures

Inspection

  1. Turn the ignition switch to the OFF position.
  2. Disconnect the battery and battery tray. (Refer to Engine Electrical System - "Battery".)
  3. Disconnect the connector (A) from the solenoid valve.
  4. Measure the resistance between the sensor signal terminal and the sensor ground terminal.
  5. Check that the resistance is within specification.