Main Relay (+) / (-) Repair procedures
Removal
Shut off the High Voltage circuit.
(Refer to Hybrid Control System - “High Voltage Shutoff Procedure”)
Remove the power relay assembly.
(Refer to High Voltage Battery System - "Power Relay Assembly (PRA)")
Remove the main relay (A).
[Main Relay (-)]

[Main Relay (+)]

Installation
Install the main relay in the reverse order of removal.
Inspection
Checking for Welding in the High Voltage Main Relay
[Using KDS/GDS service data to check for main relay weld damage]
Connect the KDS/GDS to the Data Link Connector (DLC).
Switch "ON" the ignition.
Check for BMS welding damage from KDS/GDS service data.

[Using a Multimeter to measure weld damage]
Shut off the high voltage.
(Refer to "High Voltage Shut-off Procedures")
Remove the rear seat cushion.
(Refer to Body - "Rear Seat Assembly")
Remove the rear door scuff trim.
(Refer to Body - "Door Scuff Trim")
Remove the inlet cooling duct.
(Refer to High Voltage Battery Cooling System - "Cooling Duct")
Measure the high voltage main relay resistance and check for signs of weld damage.
Specification : ∞Ω[20 °C]

High voltage main relay (-) switch resistance
[Use multi tester (relay OFF)]
Shut off the high voltage.
(Refer to "High Voltage Shut-off Procedures")
Remove the side luggage form(LH).
(Body - "Trunk Trim")
Remove the high battery top cover.
(High Battery System -"Case")
Measure the resistance between the high voltage power terminal (-) and the inverter power terminal (-).
Specification : ∞Ω[20 °C]


If the measured resistance is not within the specification, replace the main relay (-) by referring to repair procedures.
[Circuit inspection (Relay ON)
Connect the KDS/GDS to the Data Link Connector (DLC).
Switch "ON" the ignition.
Activate the main relay by using "Actuation Test" on the KDS/GDS as shown in the illustration below.

High Voltage Main Relay Coil Resistance
Shut off the high voltage.
(Refer to "High Voltage Shut-off Procedures")
Remove the power relay assembly.
(High Battery System - "Power Relay Assembly")
Check for continuity between the terminals using an ohmmeter.
Specification : 29.7 - 36.3 Ω [20 °C]