Hybrid Control System

Pre-Charge Resistor Repair procedures

7steps
~42min
3/5difficulty
Done 0 of 7

Removal

  1. Shut off the high voltage circuit.

    (Refer to Hybrid Control System - “High Voltage Shutoff Procedure”)

  2. Remove the power relay assembly.

    (Refer to High Voltage Battery System - "Power Relay Assembly (PRA)")

  3. Insert a screwdriver or an awl (B) into the hole (A).

  4. Lift the pre-charge resistor (D) in the direction of arrow (C).

  5. Remove the pre-charge resistor (A).

Inspection

  1. Remove the pre-charge resistor.

    (Refer to High Voltage Battery Control System - "Pre-Charge Resistor")

  2. Check for continuity between the terminals using an ohmmeter.

    Specification : 40Ω [20 °C]

Installation

  1. Install the pre-charge resistor in the reverse order of removal.