Abs Warning Lamp
CHECK ABS WARNING LAMP FUNCTION
Check that ABS warning lamp in combination meter turns ON for 1 second after ignition switch ON.
Is the inspection result normal?
YES>>Inspection End.
NO>>Proceed to Diagnosis Procedure.
CHECK ABS ACTUATOR AND ELECTRIC UNIT (CONTROL UNIT) POWER SUPPLY AND GROUND CIRCUIT
Perform the trouble diagnosis for ABS actuator and electric unit (control unit) power supply and ground circuit. Refer to Diagnosis Procedure.
Is the inspection result normal?
YES>>GO TO 2.
NO>>Repair or replace error-detected parts.
PERFORM SELF DIAGNOSTIC RESULT
CONSULT
Ignition switch OFF → ON.
Repeat step 1 two or more times.
Select “Self Diagnostic Result” mode of “ABS”.
Is any DTC detected?
YES>>Check the DTC. Refer to DTC Index.
NO>>GO TO 3.
CHECK ABS WARNING LAMP SIGNAL
CONSULT
Select “ABS WARN LAMP” in “Data Monitor” mode of “ABS”.
Ignition switch OFF.
Check that “Data Monitor” displays “On” for 1 second after ignition switch ON and then changes to “Off”.
Is the inspection result normal?
YES>>Replace the combination meter. Refer to Removal and Installation.
NO>>Replace the ABS actuator and electric unit (control unit). Refer to Removal and Installation.