Ecm does not receive communication signal from the stva. Stva can not operate properly or its motor locked
Stva malfunction.
Stva circuit open or short.
Stva motor malfunction.
Wiring diagram TroubleshootingCaution
when using the multi-circuit tester, do not strongly touch the terminal of the ecm coupler with a needle pointed tester probe to prevent terminal damage.
Note
after repairing the trouble, clear the dtc using sds tool. Refer to “use of sds diagnosis reset procedures” .
Step
Action
Yes
No
1
Lift and support the fuel tank. Refer to “fuel tank removal and installation” in section 1g .
Remove the air cleaner box cover. Refer to “air cleaner element removal and installation” in section 1d .
Check the stva lead wire coupler (1) for loose or poor contacts.
Check whether the stvs open by turning the ignition switch on.
Is the operation ok?
Go to step 2.
Loose or poor contacts on the stva coupler.
Open or short circuit in the b/lg, p/w, g or w/b wire.
If wire and connection are ok, go to step 2.
2
Turn the ignition switch off.
Disconnect the stva lead wire coupler.
Check the continuity between each terminal and ground.