Electrical System General Information

Battery Charger -VAS 5906-

7steps
~42min
2/5difficulty
Done 0 of 7

General description

Battery Charger - VAS 5906-


WARNING!

Risk of injury! Observe the warnings and safety regulations!


WARNING!

Do not test or charge batteries where the magic eye shows light yellow. Do not jump-start them!

There is a risk of explosion when testing, charging or jump-starting.

These batteries must be replaced.

The Battery Charger -VAS 5906- was specially developed for charging in the vehicle electrical system during vehicle presentations.

It has an automatic charging characteristic for starter batteries from 3 to 300 Ah.

The maximum charging voltage of 14.4 V is not exceeded. All electrical consumers are supported by buffer charging with up to 30 A.

For continuous operation, the Battery Charger -VAS 5906- switches to maintenance charging once the battery is fully charged.

The device starts fully automatically and requires no settings. Only the charging clamps and the mains cable need to be connected.

For more information, see the → Operating Instructions VAS 5906.

VW UP. Elektrische Anlage Allgemeine Informationen

Charging a Battery with the Battery Charger -VAS 5906-


WARNING!

Risk of injury! Observe the warnings and safety regulations!


WARNING!

Do not test or charge batteries where the magic eye shows light yellow. Do not jump-start them!

There is a risk of explosion when testing, charging or jump-starting.

These batteries must be replaced.

Overview of the Control Panel:

  1. Display: state of charge 25 %.
  2. Display: state of charge 50 %.
  3. Display: state of charge 75 %.
  4. Display: state of charge 100 %.
  5. Display: ready for operation
  6. Start/Stop and Setup button to pause and resume charging. Press for 10 s to enter the setup menu and select the characteristic type.
  7. Display: fault.

- Place the charger in the engine compartment or under the vehicle.

- Connect the mains cable to the charger and plug it into the mains.

The charger is idling - the ready-for-operation indicator lights up.


WARNING!

Risk of injury! Observe the warnings and safety regulations!

- Switch off ignition.

- Connect the red charging cable to the positive terminal "+" of the battery.


Note

On vehicles with a start/stop function and a battery monitoring control module with battery sensor -J367-, the black charging clamp - must be connected to the vehicle body ground. Connecting to the negative terminal of the battery causes malfunctions in the start/stop system.

- Connect the black charging cable to the negative connection point "-" of the battery.

Charging starts after approx. 2 s.

The LEDs that light up in sequence show the state of charge of the battery. When all lamps are lit, the battery is charged.

When the battery is full, the Battery Charger -VAS 5906- automatically switches to maintenance charging.


Caution!

Risk of sparking if the charging clamps are removed early. End the charging process by pressing the Start/Stop button.

- Press the Start/Stop button to end charging.

- Disconnect the black charging cable from the negative connection point "-" of the battery.

- Disconnect the red charging cable from the positive terminal "+" of the battery.