Air conditioning with R134a refrigerant
Blowing through the refrigerant circuit with compressed air and nitrogen
In this manual: Air conditioning with R134a refrigerant
~3min read
- Compressed air is used to force out moisture and other contaminants from the refrigerant circuit, and nitrogen is used to remove moisture from the refrigerant circuit.
- Blowing through the refrigerant circuit with compressed air and nitrogen usually requires considerably more work than flushing with refrigerant R134a. Cleaning of the components is also much better when flushing with refrigerant R134a, so flushing should always be performed in case of a complaint (blowing through should only be used for certain complaints and individual components).
Only individual components need to be blown through if:
- there is no possibility of flushing the refrigerant circuit with refrigerant R134a.
- dirt or other contaminants are present in the individual components of the circuit.
- when evacuating a sealed refrigerant circuit, the vacuum reading does not hold (moisture is in the refrigerant circuit and builds up pressure).
- the refrigerant circuit was opened beyond the normal installation time (e.g. after an accident).
- Based on pressure and temperature measurements in the circuit, it is assumed that moisture is present in the refrigerant circuit.
- the vehicle-specific repair manual → Heating, Air Conditioning requires it after replacing certain components.
![]()
Note
- Blowing through the refrigerant circuit with compressed air and nitrogen does not achieve the same cleaning level as flushing with refrigerant R134a. When flushing with refrigerant R134a, the refrigerant oil is dissolved and cleaning of the components is better.
- When blowing through, a maximum working pressure of 15 bar must not be exceeded (if necessary, also use a pressure reducer for compressed air).
![]()
WARNING!
- Nitrogen can escape uncontrolled from the cylinder.
- Only work with a pressure reducer for nitrogen cylinders (max. working pressure 15 bar).
- The gas mixture escaping from the components must be extracted using a suitable exhaust extraction system.
- Always blow through components against the direction of refrigerant flow.
Compressed air and nitrogen must not be blown through the throttle, expansion valve, compressor, liquid receiver or accumulator.
- For condensers with a desiccant cartridge installed in the integrated liquid receiver, remove this desiccant cartridge.
- First blow out dirt with compressed air, then dehumidify the components with nitrogen.
- Adapter for connecting the pressure hose to the refrigerant circuit and → Heating, Air Conditioning, connecting.
To prevent oil or moisture from the compressed air system from entering the refrigerant circuit, observe the following points.
- The compressed air must be routed through a compressed air cleaning device for cleaning and drying. Therefore, use filters and dryers for compressed air (included as tools for painting work) → Catalog of Workshop Equipment and Special Tools.
- For refrigerant lines with a thread or union nut at the connection, use adapters -V.A.G 1785/1- to -V.A.G 1785/8- to connect the filling hoses 5/8"-18 UNF. These adapters are contained in the adapter case PKW set VW/Audi -VAS 6338/1- and the adapter case commercial vehicle set -VAS 6338/50-.
- On refrigerant lines without a thread or union nut at the connection, use an adapter from the adapter set PKW-Set VW/Audi -VAS 6338/1- or adapter set NFZ-Set -VAS 6338/50-, or a commercially available blow gun with a rubber nozzle.
![]()
Note
- Extract compressed air or nitrogen escaping from the components using a suitable system (e.g. workshop extraction system).
- Certain contaminants and old refrigerant oil cannot be removed from the refrigerant circuit with compressed air, or only insufficiently. These contaminants can only be removed by flushing with refrigerant R134a.
Blowing out the refrigerant circuit
![]()
Note
- On vehicles where no adapters fit the refrigerant lines, use a blow gun with a rubber nozzle, for example, to blow out the individual components. Take particular care not to damage the connections (by crushing or scratching them).
- With the expansion valve removed or the orifice tube removed, blow out the evaporator via the connection for the low-pressure line (large diameter).
- Always blow out components against the direction of refrigerant flow.
- Check the expansion valve; replace it if contaminated or corroded.
- If dark, sticky deposits are present in the components and cannot be removed with compressed air, replace these components.
- Thin, light grey deposits on the inside of the refrigerant lines do not affect component function.
- After blowing out, always replace the receiver/drier or accumulator and the orifice tube. On condensers with an attached dryer, replace the dryer cartridge or the dryer.