Short to Battery in Motor RH Circuit (25,26)
When there is a short to battery in the side auto step motor circuit, the side auto step controller ECU assembly will not operate the automatic running board.
DTC No. | Detection Condition | Trouble Area |
|---|---|---|
25 |
Short to battery in the stowing or deploying side of the side auto step motor LH circuit when the automatic running board is not in operation. |
|
26 |
Short to battery in the stowing or deploying side of the side auto step motor RH circuit when the automatic running board is not in operation. |
PROCEDURE
CHECK HARNESS AND CONNECTOR (SIDE AUTO STEP MOTOR - SIDE AUTO STEP CONTROLLER ECU)
(a) Disconnect the O25*1 or N23*2 side auto step motor assembly connector.
- *1: for LH
- *2: for RH
(b) Disconnect the A42 side auto step controller ECU assembly connector.
(c) Measure the voltage according to the value(s) in the table below.
Standard Voltage:
for LH
Tester Connection | Condition | Specified Condition |
|---|---|---|
A42-3 (STW1) - Body ground |
When the automatic running board LH is not in operation. |
Below 1 V |
A42-4 (DPL1) - Body ground |
When the automatic running board LH is not in operation. |
Below 1 V |
for RH
Tester Connection | Condition | Specified Condition |
|---|---|---|
A42-2 (STW2) - Body ground |
When the automatic running board RH is not in operation. |
Below 1 V |
A42-1 (DPL2) - Body ground |
When the automatic running board RH is not in operation. |
Below 1 V |
| OK | ![]() | REPLACE SIDE AUTO STEP CONTROLLER ECU ASSEMBLY |
| NG | ![]() | REPAIR OR REPLACE HARNESS OR CONNECTOR |