Generator - Inspection (90 A Model)

~2min read

ROTOR

1. Проверьте отсутствие обрыва в обмотке ротора.

1. Check the rotor coil for an open circuit.

Check that there is no short circuit between the slip rings. If the resistance is too low (approaches 0), there is a short circuit. If the rotor winding is open or shorted, replace the rotor assembly.

Resistance: approximately 3.1 Ohm

2. Проверьте отсутствие замыкания обмотки ротора на "массу".

2. Check the rotor coil for a short to ground.

Check that there is no continuity between the slip ring and the core. If there is continuity (short to ground), replace the rotor assembly.

STATOR

1. Check the stator coil for an open circuit.

Check for continuity between the stator winding terminals.

Если цепь обмотки разомкнута (сопротивление стремится к бесконечности), то замените

If the winding circuit is open (resistance is infinite), replace the stator assembly.

2. Проверьте отсутствие замыкания обмотки на "массу".

2. Check that the winding is not shorted to ground.

Check that the stator winding is not shorted to ground (there should be no continuity between the stator winding and the core).

If the circuit is shorted (resistance approaches zero), replace the stator assembly.

CHECK POSITIVE RECTIFIER TERMINAL

С помощью омметра проверьте, что цепь между выводом "положительных" диодов выпрямительного

Using an ohmmeter, check that there is continuity (low resistance) between the positive diode terminal of the rectifier assembly and the stator winding terminal.

Reverse the ohmmeter probe connections and measure the resistance again. If resistance is low, i.e., there is continuity in both directions, the diode is punctured (shorted).

Replace the rectifier assembly.

CHECK NEGATIVE RECTIFIER TERMINAL

С помощью омметра проверьте, что цепь между выводом "отрицательных" диодов выпрямительного

Using an ohmmeter, check that there is continuity (low resistance) between the negative diode terminal of the rectifier assembly and the stator winding terminal.

Reverse the ohmmeter probe connections and measure the resistance again. If resistance is low, i.e., there is continuity in both directions, the diode is punctured (shorted).

Replace the rectifier assembly.

CHECK THREE RECTIFIER DIODES

Проверьте три диода, подсоединяя омметр к обоим выводам каждого диода. Для каждого

Check the three diodes by connecting the ohmmeter to both terminals of each diode. For each diode, there must be continuity in only one direction.

If there is no continuity in both directions, or if there is continuity in both directions, the diode is faulty and the rectifier (heat sink) assembly must be replaced.

Test yourself