Heating, Ventilation and Air Conditioning

Compressor Repair procedures

11steps
~66min
5/5difficulty
0102030405011.79N·mlb·ft
Tightening torque found on this page
Done 0 of 11

Removal

  1. If the compressor is marginally operable, run the engine, and let the air conditioning work for a few minutes, then shut the engine off.

  2. Disconnect the negative (-) battery terminal.

  3. Shut off the high voltage circuit.

    (Refer to Heating,Ventilation, Air Conditioning - "High Voltage Shut-off Procedures")

  4. Recover the refrigerant with a recovery/charging station.

  5. Remove the engine room under cover.

    (Refer to Engine Mechanical System - "Engine Room Under Cover")

  6. Disconnect the discharge hose (A) and suction hose (B) after loosening the nuts.

    Tightening torque : 7.8 - 11,7 N·m

  7. Disconnect the compressor connector (A) and high voltage connector (B).

  8. Remove the compressor assembly (A) after loosening the bolts.

    Tightening torque : 20.0 - 33 N·m

  9. Remove the compressor high-voltage connector (A).

Installation

  1. Make sure the compressor mounting bolt with the correct length is screwed in. Tighten the mounting bolts to the specified torque.

    Tightening torque : 20.0 - 33 N·m

  2. Install in the reverse order of removal, and note the following.