Heating, Ventilation and Air Conditioning
Evaporator Temperature Sensor Repair procedures
In this manual: Heating, Ventilation and Air Conditioning
6steps
~36min
2/5difficulty
Done 0 of 6
Inspection
Switch "OFF" the ignition.
Disconnect the evaporator temperature sensor connector.
Measure the resistance between positive (+) and negative (-) terminals of the evaporator temperature sensor.

Specification
Evaporator core temperature
[°C (°F)]Resistance [k?] Voltage [V] -10 (14) 43.35 2.96 0 (32) 27.62 2.40 10 (50) 18.07 1.88 20 (68) 12.11 1.44 30 (86) 8.30 1.08 40 (104) 5.81 0.81

1. Evaporator sensor (+) 2. Sensor ground
Replacement
Remove the evaporator core.
(Refer to Air Conditioner - "Evaporator Core".)
Remove the evaporator temperature sensor (A).

Install in the reverse order of removal..
Was this page helpful?