Heating, Ventilation and Air Conditioning

Refrigerant Line Repair procedures

6steps
~36min
3/5difficulty
Done 0 of 6

Replacement

  1. Discharge refrigerant from refrigeration system.

  2. Replace faulty tube or hose.

  3. Tighten joint of bolt or nut to specified torque.

    Tightening torque N·m kgf·m lb·ft
    Condenser - Discharge hose 7.8 - 11.8 0.8 - 1.2 5.8 - 8.7
    Condenser - Liquid tube
    Compressor - Discharge hose 7.8 - 11.8 0.8 - 1.2 5.8 - 8.7
    Compressor - Suction hose
    Expansion valve - Evaporator 7.8 - 11.8 0.8 - 1.2 5.8 - 8.7
  4. Evacuate air in refrigeration system and charge system with refrigerant.

    Specified amount : 650 ± 25 g (22.9 ± 0.88 oz.)

  5. Inspect for leakage of refrigerant.

    Using a gas leak detector, check for leakage of refrigerant.

  6. Inspect A/C operation.