Inspection
INSPECTION
PROCEDURE
1. INSPECT HAZARD WARNING SIGNAL SWITCH ASSEMBLY
(a) Check the resistance.
(1) Measure the resistance according to the value(s) shown in the table below. Standard resistance:
If the result is not as specified, replace the hazard warning switch assembly. |
|
(b) Check whether the light comes on.
(1) Apply battery voltage to the hazard warning signal switch assembly and check that the switch illuminates.
OK:
Condition | Specified Condition |
|---|---|
Battery positive (+) → Terminal 3 (+) (ILL+) Battery negative (-) → Terminal 2 (ILL-) |
Comes on |
If the result is not as specified, replace the hazard warning switch assembly.