Exterior Lighting

Inspection

~1min read

INSPECTION

PROCEDURE

1. INSPECT HAZARD WARNING SIGNAL SWITCH ASSEMBLY

(a) Check the resistance.

(1) Measure the resistance according to the value(s) shown in the table below.

Standard resistance:

Tester Connection

Condition

Specified Condition

4 (TB) - 1 (E)

Hazard warning signal switch in OFF position

10 kΩ minimum

Hazard warning signal switch in ON position

Below 1 Ω

If the result is not as specified, replace the hazard warning switch assembly.

*a

Component without wire harness connected

(hazard warning switch assembly)

(b) Check whether the light comes on.

(1) Apply battery voltage to the hazard warning signal switch assembly and check that the switch illuminates.

OK:

Condition

Specified Condition

Battery positive (+) → Terminal 3 (+) (ILL+)

Battery negative (-) → Terminal 2 (ILL-)

Comes on

If the result is not as specified, replace the hazard warning switch assembly.