Refrigerant
a. Observe the sight glass on the cooler refrigerant liquid pipe A.
Test conditions:
- Running engine at 1,500 rpm
- Blower speed control switch at ”HI”
- A/C switch ON
- Temperature control dial at ”MAX. COOL”
- Fully open the doors

| Item | Symptom |
Amount of refrigerant |
Corrective Actions |
| 1 | Bubbles present | Insufficient* |
|
| 2 | No bubbles present | None, insufficient or too much | Refer 3 and 4 |
| 3 | No temperature difference between compressor inlet and outlet | Empty or nearly empty |
|
| 4 | Considerable temperature difference between compressor inlet and outlet. | Correct or too much | Refer to 5 and 6 |
| 5 | Immediately after air conditioning is turned off, refrigerant clear | Too much |
|
| 6 | Immediately after air conditioning is turned off, refrigerant foams and then becomes clear | Correct | − |
*: Bubbles in the sight glass with ambient temperatures higher than usual can be considered normal if cooling is sufficient.
2. INSPECT REFRIGERANT PRESSURE WITH MANIFOLD GAUGE SETa. This is a method in witch the trouble is located by using a manifold gauge set. Read the manifold gauge pressure when the these conditions are established.
Test conditions:
- Temperature at the air inlet with the switch set at RECIRC is 30 − 35 °C
- Engine running at 1,500 rpm
- Blower speed control switch at ”HI” position
- Temperature control dial at ”COOL” position
- A/C switch ON
- Fully open doors
0.15 − 0.25 MPa (1.5 − 2.5 kgf/cm2) High pressure side:
1.37 − 1.57 MPa (14 − 16 kgf/cm2)

2. Moisture present in refrigeration system.

| Symptom | Probable cause | Diagnosis | Remedy |
| During operation, pressure on low pressure side sometimes become a vacuum and sometime normal | Moisture in refrigerating system freezes at expansion valve orifice causing a temporary stop of cycle, however, when it melts, normal state is restored. |
|
|
3. Insufficient coolin

| Symptom | Probable cause | Diagnosis | Corrective Actions |
|
Gas leakage in refrigeration system |
|
|
4. Poor circulation of refrigerant

| Symptom | Probable cause | Diagnosis | Corrective Action |
|
Refrigerant flow obstructed by dirt in receiver | Receiver clogged | Replace condenser |
5. Refrigerant does not circulate

| Symptom | Probable cause | Diagnosis | Corrective Actions |
|
|
Refrigerant does not circulate |
|
6. Refrigerant overcharged or insufficient cooling of conden

| Symptom | Probable cause | Diagnosis | Remedy |
|
|
|
|
7. Air present in refrigeration system

| Symptom | Probable cause | Diagnosis | Corrective Actions |
|
Air entered in refrigerating system |
|
|
8. Expansion valve improperly

| Symptom | Probable cause | Diagnosis | Corrective Actions |
|
Trouble in expansion valve |
|
Check expansion valve |
9. Defective compression compressor

| Symptom | Probable cause | Diagnosis | Corrective Actions |
|
Internal leak in compressor |
|
Repair or replace compressor |

Test yourself
A quick Toyota Camry quiz: every answer comes with an explanation and a link to the manual page.