Contents:

Single-Use Parts

Single-Use Parts

Non-reusable parts (Single-Use Parts) Workshop manual provides “Components and Components Location” which can be used to identify “Non-reusable parts”. When repairing a vehicle, Non-reusable parts such as fasteners, gaskets, washers, clips and garnishes must be replaced. Kia Non-reusable parts are designed to be installed only once. Before working on a vehicle, check “Components and Components Location” to find the non-reusable parts in a system. ※ Symbol of Non-reusable parts
Symbol Meaning
Do not reuse the part. Replace with a new one.

※ Example of “Components and Components Location”

High Voltage System General Safety Information and Caution ➤

High Voltage Shut-off Procedures

High Voltage Shut-off Procedures

High Voltage Shut-off Procedures

  • When working on the high voltage system, the work should be performed by technicians who have completed the relevant training. A lack of understanding of the high voltage system can lead to serious accidents due to electric shock or short circuit.
  • When working on the high voltage system or related components, be sure to observe and be aware of the "Safety Precautions, Cautions and Warnings". If not, it may cause serious accidents due to electric shock or short circuit.
  • When working on high voltage system, make sure to check the Personal Protective Equipment (PPE) and high voltage shut-off procedure.
High Voltage Component : Battery System Assembly (BSA), motor assembly, inverter assembly, high voltage junction box, power cable, etc.
  1. Check the Battery Management Unit (BMU) weld flag with the KDS. (Data Analysis → Battery Management System (BMS) → BMU Weld Flag)

    Specified value : NO

    Refer to the KDS screen for operating conditions and details.
  2. Open the front trunk (A).
  3. Open the low voltage (12 V) battery service cover (A).
  4. Turn the POWER OFF, separate the low voltage (12 V) battery ( - ) terminal (A).

    Tightening torque : 7.8 - 9,8 N·m

  5. Disconnect the service interlock connector (A).
    • Wait more than 5 minutes for capacitor of the high voltage battery system to be discharged completely.
    • When working on a vehicle during discharging the capacitor, it can cause an electrical shock or injury, so follow the manual.
    The service interlock connector cannot be completely removed.
  6. Remove the front under cover. (Refer to Motor and Reduction Gear System - "Front Under Cover")
  7. Remove the high voltage battery cover (A).

    Tightening torque : 7.8 - 11,8 N·m

  8. Disconnect the front high voltage junction box power cable (A).
    How to disconnect the connector
    1. Release the locking clip (A) by pulling it.
    2. Disconnect the connector by pushing the lever (A) in the direction of the arrow while pressing the locking clip (B).
  9. Remove the center floor rear under cover. (Refer to Motor and Reduction Gear System - "Rear Under Cover")
  10. Disconnect the Integrated Charge Control Unit (ICCU) connector (A).
    How to disconnect the connector
    1. Release the locking clip (A) by pulling it.
    2. Disconnect the connector while pressing the locking clip (B).
  11. Disconnect the rear high voltage junction box power cable (A).
    How to disconnect the connector
    1. Release the locking clip (A) by pulling it.
    2. Disconnect the connector by pushing the lever (A) in the direction of the arrow while pressing the locking clip (B).
  12. Measure the voltage between the high voltage power connector and high voltage battery terminal to check whether the high voltage is shut-off.
    30 V or less : Normal cut off high voltage circuit Above 30 V : Fault on high voltage circuit
    1. Measure the voltage between the high voltage power connector positive ( + ) terminal and negative ( - ) terminal.
    2. Measure the voltage between the high voltage battery positive ( + ) and negative ( - ) terminal.
    3. Measure the voltage between the high voltage battery positive ( + ) terminal and ground.
    4. Measure the voltage between the high voltage battery negative ( - ) terminal and ground.
    5. Measure the voltage between the rear high voltage battery positive ( + ) and negative ( - ) terminal.
    6. Measure the voltage between the rear high voltage battery positive ( + ) terminal and ground.
    7. Measure the voltage between the rear high voltage battery negative ( - ) terminal and ground.
    1. Check for insulation breakdown via KDS and physical leakage current before working on EV.
    2. Remove the main fuse if insulation breakdown or leakage current is suspected. (Remove the main fuse even when DTC CODE ON such as PRA malfunction) (Refer to High Voltage Battery Control System - "Main Fuse") ※ If there is no insulation breakdown or leakage current and it is normal, work without removing the main fuse.

Service Inspection Mode

Service Inspection Mode

  • When working on the high voltage system, the work should be performed by technicians who have completed the relevant training. A lack of understanding of the high voltage system can lead to serious accidents due to electric shock or short circuit.
  • When working on the high voltage system or related components, be sure to observe and be aware of the "Safety Precautions, Cautions and Warnings". If not, it may cause serious accidents due to electric shock or short circuit.
  • When working on high voltage system, make sure to check the Personal Protective Equipment (PPE) and high voltage shut-off procedure.
The service mode is used to safely perform actuation test or S/W Management related to the battery management system while keeping the Main Relay OFF.
  • The actuation test with the KDS is possible in only the service mode.
  • In service mode, it is impossible to charge the high voltage battery and using the indoor/outdoor V2L.
  1. Enter the service mode as ordered below after stopping the vehicle and opening the driver's side door.
    1. Turn the POWER ON. (Do not EV READY.)
    2. Press the audio scroll on the right side of the steering wheel and maintain it.
    3. Input the trip scroll on the left side of the steering wheel 5 times to upward within 5 seconds.
      All doors (including the hood and trunk) must be kept in a closed state, excluding the driver's side door.
  2. "Service Mode" lamp turns on in the Cluster when the vehicle is in service inspection mode. Check that the “Service Mode” lamp is turns on to ensure that service inspection mode is entered correctly. Check that entering the service mode was normally done through the cluster.
    Normal : The cluster's "Service Mode" lamp turns on and turns off after about 3 seconds.
    • If the entering to the service mode fails, retry from 1 step.
    • It is impossible to change from the service mode to EV READY.
  3. The service mode is deactivated when the POWER OFF.

Specification ➤

Components and Components Location

Component

1. Integrated Charging Control Unit (ICCU)
2. Vehicle Charge Management System (VCMS)
3. Charge Door Assembly
4. Charger Inlet Assembly
5. Multi Inverter Assembly
6. Rear High Voltage Junction Box
7. Rear Motor & Reduction Gear Assembly
8. Battery System Assembly (BSA)
9. Low Voltage (12 V) Battery
10. Front High Voltage Junction Box
11. Inverter Assembly (4WD)
12. Front Motor & Reduction Gear Assembly

Description and Operation

Description

  • An electric vehicle (EV) is not a system obtaining power through an engine, such as an internal combustion engine, but a system supplying electric power from high voltage battery for driving the motor.
  • The battery control system is a system that optimizes the state of the battery and performs various controls to minimize the risk of the battery in abnormal situations when performing functions such as supplying power for driving a vehicle and supplying power consumed indoors. Moreover the battery situation is continuously monitored.
  • In addition to controlling the charge and discharge speed of the battery, the system could detect a cell voltage, a cell temperature, and a battery current from a sensor to extend the life of the battery and improve the battery performance.
Battery Control System Function
  • It receives battery status information from various sensors of electric vehicle to prevent a failure due to a battery abnormality.
  • It receives the charging voltage of the battery for each cell and detects the charging state and the internal state of the battery.
  • Where a difference in charging voltage occurs for each cell inside a battery, the voltage deviation between the cells is reduced through cell balancing.
  • When a battery is found to be abnormal, if there is a risk due to an increase in the internal load of the battery, the main relay circuit is blocked to prevent safety accidents.
  • When charging and discharging a battery, the temperature of each cell inside the battery is detected and the battery state is continuously checked through CAN communication.
  • The charge and discharge voltages according to the cell voltage are controlled.
  • When the internal temperature of the battery rises, the internal temperature of the battery is controlled to an optimal level through cooling water and air conditioning refrigerant.
Battery Cooling Control Battery in EV vehicle have sensors for controlling internal temperature, and is applied the water cooling system for controlling the temperature to below the critical value. The coolant circulation line is changed and controlled by the 3-way valve when there is a high or low load.
  • When there is a high load, the coolant is circulated from the battery to the battery chiller and controls to air conditioning refrigerant.
  • When there is a low load, the coolant is circulated from the battery to low temperature radiator and controls the battery temperature.

System Component

  • High Voltage Battery System Assembly (BSA) : It consists of 8 Sub Battery Pack Assemblies (Sub-BPA) and it stores/supplies the electrical energy required to drive the vehicle.
  • High Voltage Battery Control System : It consists of the Battery Management Unit (BMU), the Cell Monitoring Unit (CMU), the Power Relay Assembly (PRA), and controls the State of Charge (SOC), output, fault diagnosis, battery cell balancing, power supply or shutdown in battery system.
  • High Voltage Charging System : It consists of an integrated charging control unit (ICCU) which is the integrated unit of the On-Board Charger (OBC) and the Low-voltage DC/DC Converter (LDC), the charging door assembly, and the charging inlet assembly.
  • High Voltage Distributing System : It consists of a high voltage junction box and a high voltage power cable that supplies the power supplied from the high voltage battery to each component.
  • Electric Power Conversion System : It is a system that converts power according to its use. (AC/DC ↔ DC/AC)
Battery basic configuration
  • Cell : It is the smallest unit of a battery, and the battery consists of several cells.
  • Battery Module Assembly (BMA) : It is also called a module, and combination of several cells.
  • Sub Battery Pack Assembly (Sub-BPA) : It is also called a pack, and combination of several modules.
  • Battery System Assembly (BSA) : It is also called a battery, and combination of battery packs and several components such as Battery Management System (BMS), Power Relay Assembly (PRA)

High Voltage Circuit Composition

1. Battery System Assembly (BSA)
2. Integrated Charge Control Unit (ICCU)
3. Rear High Voltage Junction Box
4. Multi Inverter Assembly
5. Charger Inlet Assembly
6. Front High Voltage Junction Box
7. Inverter Assembly (4WD)
8. Low Voltage (12 V) Battery

Special Service Tools

Special Service Tool

Tool Name / Number Illustration Description
High voltage Battery System Assembly (BSA) transport hanger
09375 - K4100
Used for transporting the high voltage Battery System Assembly (BSA)
High voltage Battery Module Assembly (BMA) transport hanger
TKS - 2301
Used to transferring the high voltage Sub Battery Pack Assembly (Sub-BPA) and Battery Module Assembly (BMA)
High voltage battery module surface pressure jig
09375 - GI800
Used for compressing the high voltage Sub Battery Pack Assembly (Sub-BPA)
High voltage battery module guide
09375 - GI900
Used for seating the high voltage battery module on the surface pressure jig
High voltage battery module disassembly jig
TMS - 1907
Used for disassembling the high voltage Sub Battery Pack Assembly (Sub-BPA)
Application guide
0K375 - CV210
Used for applying the high voltage battery gap filler
Application nozzle
0K375 - CV220
Application support
0K375 - CV230
Application dispenser gun
0K375 - CV300
TGF-NT300UL 530g cartridge
0K375 - AV300
Static mixer
09375 - GI230
High voltage Battery System Assembly (BSA) guide pin
09375 - BF000
Used for seating the high voltage Battery System Assembly (BSA) on the vehicle

Refer to the contact information below for special tools (0K375 - CV210, CV220, CV230, CV300) for gap filler application.
  • TOOL & TECH (overseas@toolntech.com)
[High voltage battery transfer hanger (09375 - K4100) Assembly drawing]

Universal Tool

Tool Name Illustration Description
Digital tester
Used for measuring the voltage, current and resistance
Mega ohm tester Used for measuring the insulation resistance, voltage, and resistance
Contact pin Use a contact pin to prevent damage on the connector and for more accurate measurement

General Equipment

Tool Name Illustration Description
High voltage battery module balancer
Tool & Tech T2000
Charging/discharging a new module when replacing a high-voltage battery module
(Balancing a new module to reduce the voltage difference with existing battery module)
EV battery pack Inspecting for air tightness tool
GIT ULT - M100
G7XKDNN001 By GIT
Used for inspecting the air tightness of the Battery System Assembly (BSA) and PE system
Upper venting valve sealing jig
G1DTDNN005 By GIT
Side venting valve sealing jig
G1DTDNN006 By GIT
Battery System Assembly (BSA) adapter
G1XTGCP003 By GIT
Used for checking data of Battery System Assembly
Helium gas and pressure regulator Used for detecting micro-leakage
(※ Helium gas detectors purchase commercial products)
Helium gas detector

Refer to the contact information below for universal tools (ULT - M100,G1DTDNN005, G1DTDNN006) for Air Tightness Inspection.
  • GIT America Inc (skyang@gitamerica.com)

Electric Power Conversion System ➤

High Voltage Battery Control System ➤

High Voltage Battery System ➤

High Voltage Charging System ➤

High Voltage Distributing System ➤