Heating,Ventilation And Air Conditioning

Heat Pump

11steps
~66min
3/5difficulty
0102030405013.710N·mlb·ft
Tightening torque found on this page
Done 0 of 11

Contents:

Accumulator Description and Operation

Description

The gas/liquid of the refrigerant is separated so that only the gaseous refrigerant can flow into the compressor.

Accumulator Removal and Installation - 2WD

Removal

  • When working on the high voltage system, the work should be performed by technicians who have completed the relevant training. A lack of understanding of the high voltage system can lead to serious accidents due to electric shock or short circuit.
  • When working on the high voltage system or related components, be sure to observe and be aware of the "Safety Precautions, Cautions and Warnings". If not, it may cause serious accidents due to electric shock or short circuit.
  • When working on high voltage system, make sure to check the Personal Protective Equipment (PPE) and high voltage shut-off procedure.
  1. Recover refrigerant by using the refrigerant recovery/recycling/charging machine. (Refer to Air conditioning System - "Refrigerant Recovery/Recycling/Charging/Vacuum/Leak Test")
  2. Remove the front trunk. (Refer to Body - "Front Trunk")
  3. Separate the suction hose 1 (A) and suction hose 2 (B) after removing the nuts.

    Tightening torque : 8.8 - 13,7 N·m

  4. Remove the accumulator (B) after separating the bracket (A) by removing the bolt.

    Tightening torque : 9.8 - 14,7 N·m

Installation

  • When working on the high voltage system, the work should be performed by technicians who have completed the relevant training. A lack of understanding of the high voltage system can lead to serious accidents due to electric shock or short circuit.
  • When working on the high voltage system or related components, be sure to observe and be aware of the "Safety Precautions, Cautions and Warnings". If not, it may cause serious accidents due to electric shock or short circuit.
  • When working on high voltage system, make sure to check the Personal Protective Equipment (PPE) and high voltage shut-off procedure.
  • Be sure to inject the specified refrigerant (R-1234yf) and refrigeration oil (POE) by using the refrigerant recovery/charging equipment dedicated to the electric compressor. Compressor damage and safety accidents may occur if refrigeration oil (PAG) of general vehicles is mixed.
  1. Install in the reverse order of removal.
    • When installing a single unit, install it to the specified torque.
    • Check for refrigerant leaks by using a gas leak detector.
    • Charge the refrigerant after removing the air in the cooling system. (Refer to Air conditioning System - "Refrigerant Recovery/Recycling/Charging/Vacuum/Leak Test")

Accumulator Removal and Installation - 4WD

Removal

  • When working on the high voltage system, the work should be performed by technicians who have completed the relevant training. A lack of understanding of the high voltage system can lead to serious accidents due to electric shock or short circuit.
  • When working on the high voltage system or related components, be sure to observe and be aware of the "Safety Precautions, Cautions and Warnings". If not, it may cause serious accidents due to electric shock or short circuit.
  • When working on high voltage system, make sure to check the Personal Protective Equipment (PPE) and high voltage shut-off procedure.
  1. Recover refrigerant by using the refrigerant recovery/recycling/charging machine. (Refer to Air conditioning System - "Refrigerant Recovery/Recycling/Charging/Vacuum/Leak Test")
  2. Remove the front trunk. (Refer to Body - "Front Trunk")
  3. Separate the suction hose 1 (A) and suction hose 2 (B) after removing the nuts.

    Tightening torque : 8.8 - 13,7 N·m

  4. Remove the accumulator (A) after removing the bolts.

    Tightening torque : 9.8 - 14,7 N·m

Installation

  • When working on the high voltage system, the work should be performed by technicians who have completed the relevant training. A lack of understanding of the high voltage system can lead to serious accidents due to electric shock or short circuit.
  • When working on the high voltage system or related components, be sure to observe and be aware of the "Safety Precautions, Cautions and Warnings". If not, it may cause serious accidents due to electric shock or short circuit.
  • When working on high voltage system, make sure to check the Personal Protective Equipment (PPE) and high voltage shut-off procedure.
  • Be sure to inject the specified refrigerant (R-1234yf) and refrigeration oil (POE) by using the refrigerant recovery/charging equipment dedicated to the electric compressor. Compressor damage and safety accidents may occur if refrigeration oil (PAG) of general vehicles is mixed.
  1. Install in the reverse order of removal.
    • When installing a single unit, install it to the specified torque.
    • Check for refrigerant leaks by using a gas leak detector.
    • Charge the refrigerant after removing the air in the cooling system. (Refer to Air conditioning System - "Refrigerant Recovery/Recycling/Charging/Vacuum/Leak Test")

Refrigerant Direction Control Valve Removal and Installation

Removal

  • When working on the high voltage system, the work should be performed by technicians who have completed the relevant training. A lack of understanding of the high voltage system can lead to serious accidents due to electric shock or short circuit.
  • When working on the high voltage system or related components, be sure to observe and be aware of the "Safety Precautions, Cautions and Warnings". If not, it may cause serious accidents due to electric shock or short circuit.
  • When working on high voltage system, make sure to check the Personal Protective Equipment (PPE) and high voltage shut-off procedure.
3-Way Valve
  1. Remove the water condenser. (Refer to Airconditioning System - "Water Condenser - Heat Pump")
  2. Disconnect the 3-way valve connector (A).
  3. Remove the 3 way valve (B) after separating the pipe (A) by removing bolt and nuts.

Installation

  • When working on the high voltage system, the work should be performed by technicians who have completed the relevant training. A lack of understanding of the high voltage system can lead to serious accidents due to electric shock or short circuit.
  • When working on the high voltage system or related components, be sure to observe and be aware of the "Safety Precautions, Cautions and Warnings". If not, it may cause serious accidents due to electric shock or short circuit.
  • When working on high voltage system, make sure to check the Personal Protective Equipment (PPE) and high voltage shut-off procedure.
  • Be sure to inject the specified refrigerant (R-1234yf) and refrigeration oil (POE) by using the refrigerant recovery/charging equipment dedicated to the electric compressor. Compressor damage and safety accidents may occur if refrigeration oil (PAG) of general vehicles is mixed.
  1. Install in the reverse order of removal.
  • Replace the O-rings at each connection with new ones, and apply a few drops of compressor oil (refrigerant oil) to the O-rings before connecting hoses or lines. To avoid leakage of R-1234yf, use the specified O-ring.
  • Charge the refrigerant system and test the air conditioner performance. (Refer to Air conditioning System - "Refrigerant Recovery/Recycling/Charging/Vacuum/Leak Test")