Heating,Ventilation And Air Conditioning

52steps
~312min
4/5difficulty
010203040509.87N·mlb·ft
Tightening torque found on this page
Done 0 of 52

Contents:

Single-Use Parts

Single-Use Parts

Non-reusable parts (Single-Use Parts) Workshop manual provides “Components and Components Location” which can be used to identify “Non-reusable parts”. When repairing a vehicle, Non-reusable parts such as fasteners, gaskets, washers, clips and garnishes must be replaced. Kia Non-reusable parts are designed to be installed only once. Before working on a vehicle, check “Components and Components Location” to find the non-reusable parts in a system. ※ Symbol of Non-reusable parts
Symbol Meaning
Do not reuse the part. Replace with a new one.

※ Example of “Components and Components Location”

High Voltage System General Safety Information and Caution ➤

High Voltage Shut-off Procedures

High Voltage Shut-off Procedures

High Voltage Shut-off Procedures

  • When working on the high voltage system, the work should be performed by technicians who have completed the relevant training. A lack of understanding of the high voltage system can lead to serious accidents due to electric shock or short circuit.
  • When working on the high voltage system or related components, be sure to observe and be aware of the "Safety Precautions, Cautions and Warnings". If not, it may cause serious accidents due to electric shock or short circuit.
  • When working on high voltage system, make sure to check the Personal Protective Equipment (PPE) and high voltage shut-off procedure.
High Voltage Component : Battery System Assembly (BSA), motor assembly, inverter assembly, high voltage junction box, power cable, etc.
  1. Check the Battery Management Unit (BMU) weld flag with the KDS. (Data Analysis → Battery Management System (BMS) → BMU Weld Flag)

    Specified value : NO

    Refer to the KDS screen for operating conditions and details.
  2. Open the front trunk (A).
  3. Open the low voltage (12 V) battery service cover (A).
  4. Turn the POWER OFF, separate the low voltage (12 V) battery ( - ) terminal (A).

    Tightening torque : 7.8 - 9,8 N·m

  5. Disconnect the service interlock connector (A).
    • Wait more than 5 minutes for capacitor of the high voltage battery system to be discharged completely.
    • When working on a vehicle during discharging the capacitor, it can cause an electrical shock or injury, so follow the manual.
    The service interlock connector cannot be completely removed.
  6. Remove the front under cover. (Refer to Motor and Reduction Gear System - "Front Under Cover")
  7. Remove the high voltage battery cover (A).

    Tightening torque : 7.8 - 11,8 N·m

  8. Disconnect the front high voltage junction box power cable (A).
    How to disconnect the connector
    1. Release the locking clip (A) by pulling it.
    2. Disconnect the connector by pushing the lever (A) in the direction of the arrow while pressing the locking clip (B).
  9. Remove the center floor rear under cover. (Refer to Motor and Reduction Gear System - "Rear Under Cover")
  10. Disconnect the Integrated Charge Control Unit (ICCU) connector (A).
    How to disconnect the connector
    1. Release the locking clip (A) by pulling it.
    2. Disconnect the connector while pressing the locking clip (B).
  11. Disconnect the rear high voltage junction box power cable (A).
    How to disconnect the connector
    1. Release the locking clip (A) by pulling it.
    2. Disconnect the connector by pushing the lever (A) in the direction of the arrow while pressing the locking clip (B).
  12. Measure the voltage between the high voltage power connector and high voltage battery terminal to check whether the high voltage is shut-off.
    30 V or less : Normal cut off high voltage circuit Above 30 V : Fault on high voltage circuit
    1. Measure the voltage between the high voltage power connector positive ( + ) terminal and negative ( - ) terminal.
    2. Measure the voltage between the high voltage battery positive ( + ) and negative ( - ) terminal.
    3. Measure the voltage between the high voltage battery positive ( + ) terminal and ground.
    4. Measure the voltage between the high voltage battery negative ( - ) terminal and ground.
    5. Measure the voltage between the rear high voltage battery positive ( + ) and negative ( - ) terminal.
    6. Measure the voltage between the rear high voltage battery positive ( + ) terminal and ground.
    7. Measure the voltage between the rear high voltage battery negative ( - ) terminal and ground.
    1. Check for insulation breakdown via KDS and physical leakage current before working on EV.
    2. Remove the main fuse if insulation breakdown or leakage current is suspected. (Remove the main fuse even when DTC CODE ON such as PRA malfunction) (Refer to High Voltage Battery Control System - "Main Fuse") ※ If there is no insulation breakdown or leakage current and it is normal, work without removing the main fuse.

Specification ➤

Description and Operation

Description and Operation

The heat pump system converts the flow of refrigerant to enable cooling/heating, minimizing battery consumption during heating and improving the driving distance of the electric vehicle. Cooling Mode Refrigerant Flow Sequence
  1. An electric compressor compresses the refrigerant.
  2. The compressed high-temperature, high-pressure refrigerant passes through the inner condenser. (there is no heat exchange with the vehicle interior)
  3. The compressed high-temperature, high-pressure refrigerant passes through the heat pump EXV without expansion. (dehumidification EXV is closed)
  4. The compressed high-temperature, high-pressure refrigerant transfers heat to the water-cooled condenser and is condensed.
  5. The refrigerant 3-way valve opens toward the outer condenser.
  6. As the refrigerant passes through the outer condenser, it releases heat to the atmosphere and is further condensed.
  7. Refrigerant expansion in SOL & TXV (SOL open, high voltage battery chiller EXV closed)
  8. The expanded, low-temperature, low-pressure refrigerant absorbs heat from the vehicle interior in the evaporator.
  9. The refrigerant that absorbs heat from inside the vehicle sends only gaseous refrigerant from the accumulator to the electric compressor.
  • EXV : Expansion Valve
  • SOL : Solenoid Valve
  • 3 W/V : 3 Way Valve
  • TXV : Thermal Expansion Valve
Battery-Only Cooling Mode
  1. An electric compressor compresses the refrigerant.
  2. The compressed high-temperature, high-pressure refrigerant passes through the inner condenser. (there is no heat exchange with the vehicle interior)
  3. The compressed high-temperature, high-pressure refrigerant passes through the heat pump EXV without expansion. (dehumidification EXV is closed)
  4. The compressed high-temperature, high-pressure refrigerant transfers heat to the water-cooled condenser and is condensed.
  5. The refrigerant 3-way valve opens toward the outer condenser.
  6. As the refrigerant passes through the outer condenser, it releases heat to the atmosphere and is further condensed.
  7. Refrigerant expansion in battery chiller. (EXV duty control, SOL & TXV solenoid valve closed)
  8. The battery chiller absorbs heat from the high voltage battery and the refrigerant expands
  9. The refrigerant that absorbs heat from inside the vehicle sends only gaseous refrigerant from the accumulator to the electric compressor.
  • EXV : Expansion Valve
  • SOL : Solenoid Valve
  • 3 W/V : 3 Way Valve
  • TXV : Thermal Expansion Valve
Interior + Battery Cooling Mode
  1. An electric compressor compresses the refrigerant.
  2. The compressed high-temperature, high-pressure refrigerant passes through the inner condenser. (there is no heat exchange with the vehicle interior)
  3. The compressed high-temperature, high-pressure refrigerant passes through the heat pump EXV without expansion. (dehumidification EXV is closed)
  4. The compressed high-temperature, high-pressure refrigerant transfers heat to the water-cooled condenser and is condensed.
  5. The refrigerant 3-way valve opens toward the outer condenser.
  6. As the refrigerant passes through the outer condenser, it releases heat to the atmosphere and is further condensed.
  7. Refrigerant expansion in SOL & TXV (solenoid valve open), Refrigerant expansion in battery chiller. (EXV duty control)
  8. The expanded low-temperature, low-pressure refrigerant absorbs heat from the vehicle interior in the evaporator and absorbs heat from the battery coolant in the battery chiller.
  9. The refrigerant that absorbs heat from inside the vehicle sends only gaseous refrigerant from the accumulator to the electric compressor.
  • EXV : Expansion Valve
  • SOL : Solenoid Valve
  • 3 W/V : 3 Way Valve
  • TXV : Thermal Expansion Valve
Heating Mode Refrigerant Flow Sequence
  1. An electric compressor compresses the refrigerant.
  2. When the compressed high-temperature and high-pressure refrigerant passes through the inner condenser, the mix door opens to the heating side to dissipate heat.
  3. The compressed high-temperature, high-pressure refrigerant works as an expansion valve through a small hole in the heat pump EXV. (the dehumidification EXV is closed)
  4. The expanded low-temperature and low-pressure refrigerant absorbs heat from the PE system in the water-cooled condenser.
  5. Refrigerant 3-way valve opens in the direction of bypassing the outer condenser to minimize heat loss in the refrigerant.
  6. Refrigerant that has absorbed heat from the drive (PE) system sends only gaseous refrigerant from the accumulator to the electric compressor.
  • EXV : Expansion Valve
  • SOL : Solenoid Valve
  • 3 W/V : 3 Way Valve
  • TXV : Thermal Expansion Valve
Heating & Dehumidification Mode
  1. An electric compressor compresses the refrigerant.
  2. When the compressed high-temperature and high-pressure refrigerant passes through the inner condenser, the mix door opens to the heating side to dissipate heat.
  3. The compressed high-temperature, high-pressure refrigerant works as an expansion valve through a small hole in the heat pump EXV.
  4. The dehumidification EXV opens and a portion of the expanded refrigerant passes through the evaporator to remove moisture from the room air.
  5. The expanded low-temperature and low-pressure refrigerant absorbs heat from the PE system in the water-cooled condenser.
  6. Refrigerant 3-way valve opens in the direction of bypassing the outer condenser to minimize heat loss in the refrigerant.
  7. Refrigerant that has absorbed heat from the drive PE system sends only gaseous refrigerant from the accumulator to the electric compressor. (refrigerant that has been partially divided to dehumidify the indoor air is recombined)
  • EXV : Expansion Valve
  • SOL : Solenoid Valve
  • 3 W/V : 3 Way Valve
  • TXV : Thermal Expansion Valve

Troubleshooting

Troubleshooting

Before repairing the air conditioning components, check the refrigerant, compressor oil, air filter.
No Blower Operation
Suspected Causes Repair
Faulty connection of connector Check the connector
Heater fuse Repair or replace
Blower relay Repair or replace
Blower Motor Repair or replace
Wiring break and short circuit Repair or replace

No Air Temperature Control
Suspected Causes Repair
Coolant amount Repair or supplement
Faulty connection of connector Check the connector
Temperature control actuator Repair or replace
Auto temperature control unit Repair or replace

No Electric A/C Compressor Operation
Suspected Causes Repair
Refrigerant amount Refrigerant charging / vacuum / leak test
A/C fuse Repair or replace
Electric A/C compressor Repair or replace
A/C pressure transducer Repair or replace
A/C switch Repair or replace
Evaporator temperature sensor Repair or replace
Wiring break and short circuit Repair or replace

Not Blowing Cold Air
Suspected Causes Repair
Refrigerant amount Refrigerant charging / vacuum / leak test
Refrigerant pressure Refrigerant charging / vacuum / leak test
Electric A/C compressor Repair or replace
A/C pressure transducer Repair or replace
Evaporator temperature sensor Repair or replace
A/C switch Repair or replace
Auto temperature control unit Repair or replace
Wiring break and short circuit Repair or replace

Insufficient Cooling
Suspected Causes Repair
Refrigerant amount Refrigerant charging / vacuum / leak test
Electric A/C compressor Repair or replace
Condenser Repair or replace
Expansion valve Repair or replace
Evaporator Repair or replace
Refrigerant line Repair or replace
A/C pressure transducer Repair or replace
Auto temperature control unit Repair or replace

Poor Air Inlet Control
Suspected Causes Repair
Faulty connection of connector Check the connector
Auto temperature control unit Repair or replace
Intake actuator Repair or replace
Wiring break and short circuit Repair or replace

No Mode Control
Suspected Causes Repair
Faulty connection of connector Check the connector
Auto temperature control unit Repair or replace
Mode control actuator Repair or replace
Wiring break and short circuit Repair or replace

No Cooling Fan Operation
Suspected Causes Repair
Faulty connection of connector Check the connector
Cooling fan fuse Repair or replace
Fan motor Repair or replace
VCU Repair or replace
Wiring break and short circuit Repair or replace

Air Conditioning System ➤

Blower ➤

Controller ➤

Heater ➤

Heat Pump ➤