Cooling System

Cooling System

101steps
~606min
4/5difficulty
010203040507.86N·mlb·ft
Tightening torque found on this page
Done 0 of 101

Contents:

Coolant Drain

Special Service Tool

Tool Name / Number Illustration Description
Coolant refiller & suction tool
0K253 - J2300
Used to drain and fill the coolant for EV
Cap adapter
0K253 - J2320
Used to drain and fill the coolant for EV

SST (0K253 - J2300) Detail Name
1. Pressure Valve
2. Suction Valve
3. Vacuum Valve 1
4. Vacuum Valve 2
5. Coolant Injection
6. Vacuum Valve
7. Regulator Pressure Gauge
8. Pressure Gauge
9. Vacuum Gauge
10. Air Pressurization Valve
11. Vacuum Outlet Valve
12. Air Hose Inlet Valve
13. Regulator Adjusting Knob

Drain

  • When working on the high voltage system, the repairs should be performed by technicians who have completed the relevant training. A lack of understanding of the high voltage system can lead to serious accidents due to electric shocks or short circuit.
  • When working a high voltage system, the technician must be recognized and observe "General Safety Information and Caution". If do not follow, serious accidents like electric shock and short circuit are caused.
  • When working on high voltage system, make sure to check the Personal Protective Equipment (PPE) and high voltage shut-off procedure.
  1. Disconnect the battery negative ( - ) terminal and the high voltage service interlock connector. (Refer to Battery Control System - "Auxiliary Battery (12 V)") (Refer to Battery Control System - "Auxiliary Battery (12 V)" -4WD)
  2. Open the reservoir tank cap (A).
  3. Install the cap adapter (0K253 - J2320).
  4. Install the radiator cap connection hose (A) to the radiator cap adapter (B).
  5. Connect the radiator cap connection hose (A) to the air pressurization valve of SST (0K253 - J2300).
  6. Install the air hose (A) to the air inlet valve of SST (0K253 - J2300).
    Make sure all valves are closed.
  7. Turn the regulator adjusting knob (A) to set pressure gauge (B) to 0.2 Mpa.
    After adjusting the pressure, close the regulator adjustment knob.
  8. Remove the front under cover. (Refer to Motor & Reduction Gear System - "Front Under Cover")
  9. Release the quick connector, and then disconnect the high voltage battery EWP cooling hose (A). [2WD] [4WD]
  10. Install the coolant drain adapter and hose (A) to the battery EWP and EWP cooling hose. [2WD] [4WD]
  11. Put the opposite of the coolant drain adapter and hose (A) to a bucket (B).
  12. Turn the pressure valve (A) the direction of the arrow to drain coolant.
    Make sure that the valves other than the pressure valve (A) are closed.
  13. Close the pressure valve after draining coolant, and then install the high voltage battery EWP coolant hose (A). [2WD] [4WD]
  14. Remove the rear under cover. (Refer to Motor and Reduction Gear System - "Rear Under Cover")
  15. Disconnect the cooling hose (A) after releasing the quick connector.
  16. Install the coolant drain adapter and hose (A) to the cooling hose.
  17. Put the opposite of the coolant drain adapter and hose (A) to a bucket (B).
  18. Turn the pressure valve (A) the direction of the arrow to drain coolant.
    Make sure that the valves other than the pressure valve (A) are closed.
  19. Close the pressure valve after draining coolant, and then install the cooling hose (A).
  20. Separate the radiator cap connection hose (A) to the air pressurization valve.

Coolant Refilling

Special Service Tool

Tool Name / Number Illustration Description
Coolant refiller & suction tool
0K253 - J2300
Used to drain and fill the coolant for EV
Cap adapter
0K253 - J2320
Used to drain and fill the coolant for EV

SST (0K253 - J2300) Detail Name
1. Pressure Valve
2. Suction Valve
3. Vacuum Valve 1
4. Vacuum Valve 2
5. Coolant Injection
6. Vacuum Valve
7. Regulator Pressure Gauge
8. Pressure Gauge
9. Vacuum Gauge
10. Air Pressurization Valve
11. Vacuum Outlet Valve
12. Air Hose Inlet Valve
13. Regulator Adjusting Knob

Refilling

  • Be careful not to spill coolant on the electric devices when replacing the coolant.
  • Use genuine antifreeze/coolant.
  • To prevent corrosion, the concentration of coolant should be maintained at a minimum of 45%. If the coolant concentration is less than 45%, there may be a risk of corrosion or freezing.
  • It is not recommended if the concentration of the coolant exceeds 60%, as the cooling effect may be reduced.
  • Do not mix antifreeze/coolant from different brands.
  • Do not add any anti-rust.
  1. Drain the coolant. (Refer to Coolant - "Drain")
  2. Connect the radiator cap connection hose (A) to the vacuum valve of SST (0K253 - J2300).
  3. Open the vacuum valve (A) in the direction of the arrow, and then close when the vacuum gauge (B) reaches the green area (C).
    Make sure that the valves other than the vacuum valve (A) are closed.
  4. Connect the coolant suction hose (A) to SST (0K253 - J2300) coolant filler valve and place the opposite hose in the bucket (B) containing new coolant.
  5. Turn the suction valve (A) in the direction of the arrow to fill new coolant, and then close it when the vacuum gauge reaches to '0'.
    Check that the valve except the suction valve (A) is locked.
  6. Remove the cap adapter (0K253 - J2320).
  7. Perform the order below with the KDS. (S/W Management → Vehicle Control → Electric Water Pump Control)
    Charge the auxiliary 12 V battery during performing "Electric Water Pump Control" to prevent battery drain.
    When driving EWP, operate within 10 minutes.
  8. When the EWP operates and coolant circulates, refill coolant so that the coolant level is kept between "MAX" and "MIN" level.
    Friction may damage the bearing if the EWP is operated without coolant.
  9. When the operational sound volume of the EWP becomes small and when no air bubbles can be seen in the reservoir tank, bleeding of the coolant system is completed.
    • After air bleeding is completed make sure that coolant in the reservoir tank flow without air bubble during the EWP actuation.
    • If the coolant flow is not seen or air bubbles are still seen, repeat steps 7 to 8.
  10. Perform the order below with the KDS. (Actuation Test → Vehicle Control → Battery EWP Operation Mode for Degassing and Circulation)
    Charge the auxiliary 12 V battery during performing "Battery Electric Water Pump Control" to prevent battery drain.
    When driving EWP, operate within 10 minutes.
  11. When the battery EWP operates and coolant circulates, refill coolant so that the coolant level is kept between "MAX" and "MIN" level.
    Friction may damage the bearing if the EWP is operated without coolant.
  12. When the operational sound volume of the EWP becomes small and when no air bubbles can be seen in the reservoir tank, bleeding of the coolant system is completed.
    • After air bleeding is completed make sure that coolant in the reservoir flow without air bubble during the EWP actuation.
    • If the coolant flow is not seen or air bubbles are still seen, repeat steps 10 to 11.
  13. After air bleeding is completed, refill the coolant to the MAX level and install the reservoir cap.
  14. Check the coolant for leakage.
    The cooling system air bleeding and coolant injection are performed perfectly when the coolant is completely cooled. Check the coolant level of the reservoir tank for 2 - 3 days after flushing the coolant.
  15. Install the front under cover. (Refer to Motor & Reduction Gear System - "Front Under Cover")
  16. Install the rear under cover. (Refer to Motor and Reduction Gear System - "Rear Under Cover")

Cooling Fan Specification. Cooling Fan Components and Components Location

Cooling Fan Specification

Specification

Item Specification
Control type PWM
Fan speed (rpm) 2,352 - 2,548
Current consumption (A) 44.1 - 53.9

Cooling Fan Components and Components Location

Component and Component Location

1. Cooling Fan Assembly
1-a. 4.9 - 7,8 N·m (0.5 - 0.8 kgf·m, 3.6 - 5.8 lb·ft, 43.4 - 69.4 lb·in)

Cooling Fan On Vehicle Inspection

Inspection

  1. The cooling system can be more quickly diagnosed for problems using the KDS (Refer to "DTC guide").
    1. Actuation test : Checking the system operation condition (Data Analysis → Actuation Test → Radiator Fan Forced Operation)
    Refer to the KDS screen for operating conditions and details

Cooling Fan Removal and Installation - 2WD

Removal

  • When working on the high voltage system, the repairs should be performed by technicians who have completed the relevant training. A lack of understanding of the high voltage system can lead to serious accidents due to electric shocks or short circuit.
  • When working a high voltage system, the technician must be recognized and observe "General Safety Information and Caution". If do not follow, serious accidents like electric shock and short circuit are caused.
  • When working on high voltage system, make sure to check the Personal Protective Equipment (PPE) and high voltage shut-off procedure.
  1. Remove the front trunk. (Refer to Body - "Front Trunk")
  2. Disconnect the cooling fan connector (A).
  3. Separate the radiator upper hose clips (A).
  4. Remove the cooling fan bolts (A).
    Tightening torque : 4.9 - 7,8 N·m (0.5 - 0.8 kgf·m, 3.6 - 5.8 lb·ft, 43.4 - 69.4 lb·in)
    [LH] [RH]
  5. Remove the cooling fan assembly (A).

Installation

  1. Install in the reverse order of removal.

Cooling Fan Removal and Installation - 4WD

Removal

  • When working on the high voltage system, the repairs should be performed by technicians who have completed the relevant training. A lack of understanding of the high voltage system can lead to serious accidents due to electric shocks or short circuit.
  • When working a high voltage system, the technician must be recognized and observe "General Safety Information and Caution". If do not follow, serious accidents like electric shock and short circuit are caused.
  • When working on high voltage system, make sure to check the Personal Protective Equipment (PPE) and high voltage shut-off procedure.
  1. Remove the front trunk. (Refer to Body - "Front Trunk")
  2. Remove the auxiliary 12 V battery tray. (Refer to Battery Control System - "Auxiliary 12 V Battery")
  3. Disconnect the cooling fan connector (A).
  4. Separate the radiator upper hose clips (A).
  5. Remove the cooling fan bolts (A).
    Tightening torque : 4.9 - 7,8 N·m (0.5 - 0.8 kgf·m, 3.6 - 5.8 lb·ft, 43.4 - 69.4 lb·in)
    [LH] [RH]
  6. Remove the cooling fan assembly (A).

Installation

  1. Install in the reverse order of removal.

Radiator Components and Components Location

Component and Component Location

1. Low Temperature Radiator
1-a. 4.9 - 7,8 N·m (0.5 - 0.8 kgf·m, 3.6 - 5.8 lb·ft, 43.4 - 69.4 lb·in)
2. High Temperature Radiator

Radiator Removal and Installation

Removal

  • When working on the high voltage system, the repairs should be performed by technicians who have completed the relevant training. A lack of understanding of the high voltage system can lead to serious accidents due to electric shocks or short circuit.
  • When working a high voltage system, the technician must be recognized and observe "General Safety Information and Caution". If do not follow, serious accidents like electric shock and short circuit are caused.
  • When working on high voltage system, make sure to check the Personal Protective Equipment (PPE) and high voltage shut-off procedure.
Follow the instructions below when releasing the quick connector. - Pull the quick connector clamp (A) in the direction of the arrow to separate the clamp and remove the hose. - Do not touch the rubber seal (A) inside the hose.
Low Temperature Radiator
  1. Drain the coolant. (Refer to Coolant - "Drain")
  2. Remove the front trunk. (Refer to Body - "Front Trunk")
  3. Remove the front bumper beam. (Refer to Body - "Front Bumper Beam Assembly")
  4. Disconnect the high temperature radiator upper cooling hose (A) after releasing the quick connector.
  5. Disconnect the low temperature radiator upper cooling hose (A) after releasing the quick connector.
  6. Remove the cooling fan. (Refer to Cooling Fan - "Removal and Installation - 2WD") (Refer to Cooling Fan - "Removal and Installation - 4WD")
  7. Remove the wiring clip (A).
  8. Remove the radiator upper air guard (A) after removing the bolts.

    Tightening torque : 7.8 - 11,8 N·m

  9. Remove the radiator lower air guard (A) after removing the bolts.

    Tightening torque : 7.8 - 11,8 N·m

  10. Remove the condenser pipe bolt (A).

    Tightening torque : 7.8 - 11,8 N·m

  11. Separate the condenser (A) after removing the bolts.
    Tightening torque : 4.9 - 7,8 N·m (0.5 - 0.8 kgf·m, 3.6 - 5.8 lb·ft, 43.4 - 69.4 lb·in)
  12. Disconnect the high temperature radiator lower cooling hose (A) and low temperature radiator lower cooling hose (B) after releasing the quick connectors.
  13. Remove the radiator upper bracket (A) after removing the bolts.

    Tightening torque : 7.8 - 11,8 N·m

    [LH] [RH]
  14. Remove the high and low temperature radiators (A).
  15. Remove the low temperature radiator bolts (A).
    Tightening torque : 4.9 - 7,8 N·m (0.5 - 0.8 kgf·m, 3.6 - 5.8 lb·ft, 43.4 - 69.4 lb·in)
  16. Remove the low temperature radiator (A).
  17. Remove the high and low temperature radiators.
  18. Remove the low temperature radiator bolts (A).
    Tightening torque : 4.9 - 7,8 N·m (0.5 - 0.8 kgf·m, 3.6 - 5.8 lb·ft, 43.4 - 69.4 lb·in)
  19. Remove the high temperature radiator (A).
High Temperature Radiator

Installation

  1. Install in the reverse order of removal.
  2. Perform the air bleeding procedures using the KDS after refilling the coolant. (Refer to Coolant - "Refilling")
    Perform "Electric Water Pump Control" and "Battery EWP Operation Mode for Degassing and Circulation" to air bleeding using KDS when filling with coolant.

Active Air Flap (AAF) Components and Components Location. Active Air Flap (AAF) On Vehicle Inspection

Active Air Flap (AAF) Components and Components Location

Component and Component Location

1. Front Bumper Assembly
2. Active Air Flap (AAF)
2-a. 1.0 - 2 N·m (0.1 - 0.2 kgf·m, 0.7 - 1.4 lb·ft, 8.7 - 17.4 lb·in)
3. Active Air Flap Actuator
3-a. 1.0 - 2 N·m (0.1 - 0.2 kgf·m, 0.7 - 1.4 lb·ft, 8.7 - 17.4 lb·in)

Active Air Flap (AAF) On Vehicle Inspection

Inspection

  1. The cooling system can be more quickly diagnosed for problems using the KDS (Refer to "DTC guide").
    1. Self diagnosis : Inspect the Diagnostic Trouble Code (DTC) using the KDS (Refer to DTC guide when fault code is found.)
    Refer to the KDS screen for operating conditions and details

Active Air Flap (AAF) Removal and Installation

Removal

Active Air Flap (AAF)
  1. Remove the front bumper. (Refer to Body - "Front Bumper Assembly")
  2. Disconnect the AAF actuator connector (A).
  3. Disconnect the ambient temperature sensor connector (A).
  4. Remove the AAF (A) after removing the screws.
    Tightening torque : 1.0 - 2 N·m (0.1 - 0.2 kgf·m, 0.7 - 1.4 lb·ft, 8.7 - 17.4 lb·in)
  5. Disconnect the AAF actuator connector (A).
  6. Remove the AAF actuator (A) after removing the screws.
    Tightening torque : 1.0 - 2 N·m (0.1 - 0.2 kgf·m, 0.7 - 1.4 lb·ft, 8.7 - 17.4 lb·in)
Active Air Flap (AAF) Actuator

Installation

  1. Install in the reverse order of removal.

Reservoir Tank Removal and Installation - 2WD

Removal

  • When working on the high voltage system, the repairs should be performed by technicians who have completed the relevant training. A lack of understanding of the high voltage system can lead to serious accidents due to electric shocks or short circuit.
  • When working a high voltage system, the technician must be recognized and observe "General Safety Information and Caution". If do not follow, serious accidents like electric shock and short circuit are caused.
  • When working on high voltage system, make sure to check the Personal Protective Equipment (PPE) and high voltage shut-off procedure.
When disconnecting a quick connector, refer to the following according to the type of quick connector. [Type A] - Remove while pressing the quick connector clamp (A) in the direction of the arrow. - Do not touch the rubber seal (A) inside the hose. [Type B] - Pull the quick connector clamp (A) in the direction of the arrow to separate the clamp and remove the hose. - Do not touch the rubber seal (A) inside the hose.
  1. Remove the front trunk. (Refer to Body - "Front Trunk")
  2. Drain the coolant. (Refer to Coolant - "Drain")
  3. Remove the 3 way valve. (Refer to Motor Cooling System - "3 Way Valve")
  4. Disconnect the reservoir tank cooling hose (A) after releasing the quick connector.
  5. Disconnect the high voltage battery EWP connector (A) and wiring clip (B).
  6. Disconnect the motor EWP connector (A).
  7. Disconnect the motor EWP cooling hose (A) after releasing the quick connector.
  8. Disconnect the high voltage battery EWP cooling hose (A) after releasing the quick connector.
  9. Remove the reservoir tank assembly (A) after removing the bolts and nut.

    Tightening torque : 7.8 - 11,8 N·m

  10. Remove the electric water pump (A) after removing the bolts.
    Tightening torque : 2.0 - 2,5 N·m (0.2 - 0.25 kgf·m, 1.4 - 1.8 lb·ft, 17.4 - 21.7 lb·in)
    [Motor] [Battery]
  11. Remove the reservoir tank (A) after removing the bolts.

    Tightening torque : 7.8 - 11,8 N·m

Installation

  1. Install in the reverse order of removal.
  2. Perform the air bleeding procedures using the KDS after refilling the coolant. (Refer to Coolant - "Refilling")
    Perform "Electric Water Pump Control" and "Battery EWP Operation Mode for Degassing and Circulation" to air bleeding using KDS when filling with coolant.

Reservoir Tank Removal and Installation - 4WD

Removal

  • When working on the high voltage system, the repairs should be performed by technicians who have completed the relevant training. A lack of understanding of the high voltage system can lead to serious accidents due to electric shocks or short circuit.
  • When working a high voltage system, the technician must be recognized and observe "General Safety Information and Caution". If do not follow, serious accidents like electric shock and short circuit are caused.
  • When working on high voltage system, make sure to check the Personal Protective Equipment (PPE) and high voltage shut-off procedure.
When disconnecting a quick connector, refer to the following according to the type of quick connector. [Type A] - Remove while pressing the quick connector clamp (A) in the direction of the arrow. - Do not touch the rubber seal (A) inside the hose. [Type B] - Pull the quick connector clamp (A) in the direction of the arrow to separate the clamp and remove the hose. - Do not touch the rubber seal (A) inside the hose.
  1. Remove the front trunk. (Refer to Body - "Front Trunk")
  2. Drain the coolant. (Refer to Coolant - "Drain")
  3. Remove the 3 way valve. (Refer to Motor Cooling System - "3 Way Valve")
  4. Disconnect the reservoir tank cooling hose (A) after releasing the quick connector.
  5. Disconnect the high voltage battery EWP connector (A) and wiring clip (B).
  6. Disconnect the motor EWP connector (A).
  7. Disconnect the motor EWP cooling hose (A) after releasing the quick connector.
  8. Disconnect the water condenser cooling hose (A) after releasing the quick connector.
  9. Disconnect the high voltage battery EWP cooling hose (A) after releasing the quick connector.
  10. Remove the reservoir tank assembly (A) after removing the bolts and nut.

    Tightening torque : 7.8 - 11,8 N·m

  11. Remove the electric water pump (A) after removing the bolts.
    Tightening torque : 2.0 - 2,5 N·m (0.2 - 0.25 kgf·m, 1.4 - 1.8 lb·ft, 17.4 - 21.7 lb·in)
    [Motor] [Battery]
  12. Remove the reservoir tank (A) after removing the bolts.

    Tightening torque : 7.8 - 11,8 N·m

Installation

  1. Install in the reverse order of removal.
  2. Perform the air bleeding procedures using the KDS after refilling the coolant. (Refer to Coolant - "Refilling")
    Perform "Electric Water Pump Control" and "Battery EWP Operation Mode for Degassing and Circulation" to air bleeding using KDS when filling with coolant.