Cooling System

Motor Cooling System

62steps
~372min
4/5difficulty
0102030405011.89N·mlb·ft
Tightening torque found on this page
Done 0 of 62

Contents:

Motor Coolant Drain

Special Service Tool

Tool Name / Number Illustration Description
Coolant refiller & suction tool
0K253 - J2300
Used to drain and fill the coolant for EV
Cap adapter
0K253 - J2320
Used to drain and fill the coolant for EV

SST (0K253 - J2300) Detail Name
1. Pressure Valve
2. Suction Valve
3. Vacuum Valve 1
4. Vacuum Valve 2
5. Coolant Injection
6. Vacuum Valve
7. Regulator Pressure Gauge
8. Pressure Gauge
9. Vacuum Gauge
10. Air Pressurization Valve
11. Vacuum Outlet Valve
12. Air Hose Inlet Valve
13. Regulator Adjusting Knob

Drain

  • When working on the high voltage system, the repairs should be performed by technicians who have completed the relevant training. A lack of understanding of the high voltage system can lead to serious accidents due to electric shocks or short circuit.
  • When working a high voltage system, the technician must be recognized and observe "General Safety Information and Caution". If do not follow, serious accidents like electric shock and short circuit are caused.
  • When working on high voltage system, make sure to check the Personal Protective Equipment (PPE) and high voltage shut-off procedure.
  1. Disconnect the battery negative ( - ) terminal and the high voltage service interlock connector. (Refer to Battery Control System - "Auxiliary Battery (12 V)") (Refer to Battery Control System - "Auxiliary Battery (12 V)" -4WD)
  2. Open the reservoir tank cap (A).
  3. Install the cap adapter (0K253 - J2320).
  4. Install the radiator cap connection hose (A) to the radiator cap adapter (B).
  5. Connect the radiator cap connection hose (A) to the air pressurization valve of SST (0K253 - J2300).
  6. Install the air hose (A) to the air inlet valve of SST (0K253 - J2300).
    Make sure all valves are closed.
  7. Turn the regulator adjusting knob (A) to set pressure gauge (B) to 0.2 Mpa.
    After adjusting the pressure, close the regulator adjustment knob.
  8. Remove the rear under cover. (Refer to Motor and Reduction Gear System - "Rear Under Cover")
  9. Disconnect the cooling hose (A) after releasing the quick connector.
  10. Install the coolant drain adapter and hose (A) to the cooling hose.
  11. Put the opposite of the coolant drain adapter and hose (A) to a bucket (B).
  12. Turn the pressure valve (A) the direction of the arrow to drain coolant.
    Make sure that the valves other than the pressure valve (A) are closed.
  13. Close the pressure valve after draining coolant, and then install the cooling hose (A).
  14. Separate the radiator cap connection hose (A) to the air pressurization valve.

Motor Coolant Refilling

Special Service Tool

Tool Name / Number Illustration Description
Coolant refiller & suction tool
0K253 - J2300
Used to drain and fill the coolant for EV
Cap adapter
0K253 - J2320
Used to drain and fill the coolant for EV

SST (0K253 - J2300) Detail Name
1. Pressure Valve
2. Suction Valve
3. Vacuum Valve 1
4. Vacuum Valve 2
5. Coolant Injection
6. Vacuum Valve
7. Regulator Pressure Gauge
8. Pressure Gauge
9. Vacuum Gauge
10. Air Pressurization Valve
11. Vacuum Outlet Valve
12. Air Hose Inlet Valve
13. Regulator Adjusting Knob

Refilling

  • Be careful not to spill coolant on the electric devices when replacing the coolant.
  • Use genuine antifreeze/coolant.
  • To prevent corrosion, the concentration of coolant should be maintained at a minimum of 45%. If the coolant concentration is less than 45%, there may be a risk of corrosion or freezing.
  • It is not recommended if the concentration of the coolant exceeds 60%, as the cooling effect may be reduced.
  • Do not mix antifreeze/coolant from different brands.
  • Do not add any anti-rust.
  1. Drain the motor coolant. (Refer to Motor Coolant - "Drain")
  2. Connect the radiator cap connection hose (A) to the vacuum valve of SST (0K253 - J2300).
  3. Open the vacuum valve (A) in the direction of the arrow, and then close when the vacuum gauge (B) reaches the green area (C).
    Make sure that the valves other than the vacuum valve (A) are closed.
  4. Connect the coolant suction hose (A) to SST (0K253 - J2300) coolant filler valve and place the opposite hose in the bucket (B) containing new coolant.
  5. Turn the suction valve (A) in the direction of the arrow to fill new coolant, and then close it when the vacuum gauge reaches to '0'.
    Check that the valve except the suction valve (A) is locked.
  6. Remove the cap adapter (0K253 - J2320).
  7. Perform the order below with the KDS. (S/W Management → Vehicle Control → Electric Water Pump Control)
    Charge the auxiliary 12 V battery during performing "Electric Water Pump Control" to prevent battery drain.
    When driving EWP, operate within 10 minutes.
  8. When the EWP operates and coolant circulates, refill coolant so that the coolant level is kept between "MAX" and "MIN" level.
    Friction may damage the bearing if the EWP is operated without coolant.
  9. When the operational sound volume of the EWP becomes small and when no air bubbles can be seen in the reservoir tank, bleeding of the coolant system is completed.
    • After air bleeding is completed make sure that coolant in the reservoir tank flow without air bubble during the EWP actuation.
    • If the coolant flow is not seen or air bubbles are still seen, repeat steps 7 to 8.
  10. Install the rear under cover. (Refer to Motor and Reduction Gear System - "Rear Under Cover")

Motor and Reduction Gear Oil Cooler Components and Components Location

Component and Component Location

Front Motor
1. Motor and Reduction Gear Oil Cooler Cooling Hose
2. Motor and Reduction Gear Oil Cooler Cooling Hose
3. Motor and Reduction Gear Oil Cooler Hose
4. Motor and Reduction Gear Oil Cooler Hose
5. Front Motor and Reduction Gear Oil Cooler
5-a. 7.8 - 11,8 N·m

Rear Motor
1. Motor and Reduction Gear Oil Cooler Cooling Hose
2. Motor and Reduction Gear Oil Cooler Cooling Hose
3. Motor and Reduction Gear Oil Cooler Hose
4. Motor and Reduction Gear Oil Cooler Hose
5. Rear Motor and Reduction Gear Oil Cooler
5-a. 7.8 - 11,8 N·m

Motor and Reduction Gear Oil Cooler Removal and Installation - Front Motor

Removal

  • When working on the high voltage system, the repairs should be performed by technicians who have completed the relevant training. A lack of understanding of the high voltage system can lead to serious accidents due to electric shocks or short circuit.
  • When working a high voltage system, the technician must be recognized and observe "General Safety Information and Caution". If do not follow, serious accidents like electric shock and short circuit are caused.
  • When working on high voltage system, make sure to check the Personal Protective Equipment (PPE) and high voltage shut-off procedure.
Follow the instructions below when releasing the quick connector. - Pull the quick connector clamp (A) in the direction of the arrow to separate the clamp and remove the hose. - Do not touch the rubber seal (A) inside the hose.
  1. Drain the motor coolant. (Refer to Motor Coolant - "Drain")
  2. Remove the front under cover. (Refer to Motor & Reduction Gear System - "Front Under Cover")
  3. Drain the front motor and reduction gear oil. (Refer to Motor and Reduction Gear System - "Front Motor and Reduction Gear Oil")
  4. Disconnect the motor and reduction gear oil cooler cooling hoses (A) after releasing the quick connectors.
  5. Separate the motor and reduction gear oil cooler hoses (A) after releasing the clamps.
  6. Remove the motor and reduction gear oil cooler (A) after removing the bolts and nut.

    Tightening torque : 7.8 - 11,8 N·m

Installation

  • When working on the high voltage system, the repairs should be performed by technicians who have completed the relevant training. A lack of understanding of the high voltage system can lead to serious accidents due to electric shocks or short circuit.
  • When working a high voltage system, the technician must be recognized and observe "General Safety Information and Caution". If do not follow, serious accidents like electric shock and short circuit are caused.
  • When working on high voltage system, make sure to check the Personal Protective Equipment (PPE) and high voltage shut-off procedure.
  1. Install in the reverse order of removal.
  2. Refill the front motor and reduction gear oil. (Refer to Motor and Reduction Gear System - "Front Motor and Reduction Gear Oil")
  3. Perform the air bleeding procedures using the KDS after refilling the coolant. (Refer to Motor Coolant - "Refilling")
    Perform "Electric Water Pump Control" to air bleeding using KDS when filling with coolant.

Motor and Reduction Gear Oil Cooler Removal and Installation - Rear Motor

Removal

  • When working on the high voltage system, the repairs should be performed by technicians who have completed the relevant training. A lack of understanding of the high voltage system can lead to serious accidents due to electric shocks or short circuit.
  • When working a high voltage system, the technician must be recognized and observe "General Safety Information and Caution". If do not follow, serious accidents like electric shock and short circuit are caused.
  • When working on high voltage system, make sure to check the Personal Protective Equipment (PPE) and high voltage shut-off procedure.
When disconnecting a quick connector, refer to the following according to the type of quick connector. [Type A] - Remove while pressing the quick connector clamp (A) in the direction of the arrow. - Do not touch the rubber seal (A) inside the hose. [Type B] - Pull the quick connector clamp (A) in the direction of the arrow to separate the clamp and remove the hose. - Do not touch the rubber seal (A) inside the hose.
  1. Drain the motor coolant. (Refer to Motor Coolant - "Drain")
  2. Remove the rear under cover. (Refer to Motor and Reduction Gear System - "Rear Under Cover")
  3. Drain the rear motor and reduction gear oil. (Refer to Motor and Reduction Gear System - "Rear Motor and Reduction Gear Oil")
  4. Separate the motor and reduction gear oil cooler hoses (A) after releasing the clamps.
  5. Disconnect the motor and reduction gear oil cooler cooling hoses (A) after releasing the quick connectors.
  6. Remove the motor and reduction gear oil cooler (A) after removing the bolts and nut.

    Tightening torque : 7.8 - 11,8 N·m

Installation

  1. Install in the reverse order of removal.
  2. Refill the rear motor and reduction gear oil. (Refer to Motor and Reduction Gear System - "Rear Motor and Reduction Gear Oil")
  3. Perform the air bleeding procedures using the KDS after refilling the coolant. (Refer to Motor Coolant - "Refilling")
    Perform "Electric Water Pump Control" to air bleeding using KDS when filling with coolant.

3 Way Valve Specification. 3 Way Valve Components and Components Location

3 Way Valve Specification

Specification

Item Specification
Operation voltage (V) 9 - 16
Rated current (A) Maximum 1.2
Operating temperature [°C (°F)] -40 to 90 (-40 to 194)

3 Way Valve Components and Components Location

Component and Component Location

2WD
1. 3-Way Valve Cooling Hose
2. 3-Way Valve Cooling Hose
3. 3-Way Valve Cooling Hose
4. 3-Way Valve
4-a. 19.6 - 24 N·m
5. 3-Way Valve Hose
6. 3-Way Valve Hose
7. Coolant 3-Way Valve
7-a. 7.8 - 11,8 N·m

4WD
1. 3-Way Valve Inlet Hose
2. 3-Way Valve Outlet Hose
3. 3-Way Valve Outlet Hose
4. 3-Way Valve
4-a. 19.6 - 24 N·m
5. 3-Way Valve Hose
6. 3-Way Valve Hose
7. Coolant 3-Way Valve
7-a. 7.8 - 11,8 N·m

3 Way Valve Description and Operation

Description and Operation

It by passes the coolant to the radiator when the heater pump is working to improve the heating performance of the heater pump. The electric actuator turns the ball valve to determine the coolant outlet based on the angle of the ball.

3 Way Valve Removal and Installation

Removal

  • When working on high voltage system, the work should be performed by technicians who have completed the relevant training. It is because that lack of knowledge of the high voltage system can lead to serious accidents due to electric shock or electric leakage.
  • When working a high voltage system, the technician must be recognized and observe "General Safety Information and Caution". If do not follow, serious accidents like electric shock and short circuit are caused.
  • When working on high voltage system, make sure to check the Personal Protective Equipment (PPE) and high voltage shut-off procedures.
  • Use a fender cover to protect the painted surface.
  • Be careful not to damage the connector when disconnecting.
  • When disconnecting a quick connector, refer to the following according to the type of quick connector. [Type A] - Remove the while pressing the quick connector clamp (A) in the direction of the arrow. - Do not touch the rubber seal (B) inside the hose. [Type B] - Pull the quick connector clamp (A) in the direction of the arrow to separate the clamp and remove the hose. - Do not touch the rubber seal (B) inside the hose.
  1. Disconnect the battery negative ( - ) terminal and the service interlock connector. (Refer to Battery Control System - "Auxiliary 12 V Battery")
  2. Remove the front trunk. (Refer to Body - "Front Trunk")
  3. Open the reservoir tank pressure cap (A).
  4. Use a suction device to drain the motor coolant (A) from the reservoir tank.
    Be careful not to let unwanted materials get into the reservoir tank while draining the coolant.

    A: Motor coolant B: High voltage battery coolant

  5. Disconnect the cooling hose (A) after releasing the quick connector.
    When separating the hose, the remaining coolant drains. Work carefully.
  6. Remove the bolts, and then remove the coolant 3way valve (A).

    Tightening torque : 7.8 - 11,8 N·m

    Work carefully because residual coolant can drain when removing the 3way valve.
  7. Disconnect the 3-way valve connector (B), and remove the 3way valve (A).
    Make sure the 2ea O-rings (A) are installed for the coolant 3way valve.

Installation

  • When working on high voltage system, the work should be performed by technicians who have completed the relevant training. It is because that lack of knowledge of the high voltage system can lead to serious accidents due to electric shock or electric leakage.
  • When working a high voltage system, the technician must be recognized and observe "General Safety Information and Caution". If do not follow, serious accidents like electric shock and short circuit are caused.
  • When working on high voltage system, make sure to check the Personal Protective Equipment (PPE) and high voltage shut-off procedures.
  1. Install in the reverse order of removal.
    Make sure the quick connector is installed securely after installing coolant hose. [Type A] - Make sure the quick connector (A) is installed securely. [Type B] - Make sure the quick connector and quick connector clamp is installed securely. - Make sure that the quick connector protrusion (A) fits into the groove (B).
  2. Fill the coolant to the "MAX" line.
  3. Perform the procedure below with the KDS. (S/W Management → Vehicle Control → Electric Water Pump Control)
    Charge the auxiliary 12 V battery during "EWP Actuation Test" to prevent battery drain.
    When driving EWP, operate within 10 minutes.
  4. When the EWP operates and coolant circulates, fill coolant so that the coolant level is kept between "MAX" and "MIN" level.
    Friction can cause damage to the bearing if the EWP operates without coolant.
  5. When the operating volume of the EWP becomes small and when no air bubbles can be seen in the reservoir tank, bleeding of the coolant system is completed.
    • After air bleeding is completed make sure that coolant in the reservoir tank flows without air bubble during the EWP actuation.
    • If the coolant flow is not seen or air bubbles are still seen, repeat steps 3 to 4.
  6. Close the reservoir tank pressure cap (A).

Electric Water Pump (EWP) Specification

Specification

Item Specification
Operation voltage (V) 9 - 16
Rated current (A) Maximum 10
Operating temperature [°C (°F)] -40 to 135 (-40 to 275)

Electric Water Pump (EWP) Components and Components Location

Component and Component Location

When checking the sensor data in KDS, the numbering of EWP will be different between Parts catalog and KDS data.
Part Number (Part Name) Location Mark Number
KDS Workshop Manual
375W5-CV000
(WATER PUMP ASSY-ELECTRIC NO.1)
In front of the reservoir EWP#2 EWP1
375V5-GI000,GI200
(WATER PUMP ASSY-ELECTRIC NO.2)
The underside of the vehicle
(Behind the motor)
EWP#1 EWP2

[2WD]

1. Battery Electric Water Pump (EWP) 1
1-a. 2.0 - 2,5 N·m (0.20 - 0.25 kgf·m, 1.4 - 1.8 lb·ft, 17.4 - 21.7 lb·in)
2. Motor Electric Water Pump (EWP)
2-a. 2.0 - 2,5 N·m (0.20 - 0.25 kgf·m, 1.4 - 1.8 lb·ft, 17.4 - 21.7 lb·in)
3. Reservoir Tank Bracket
3-a. 7.8 - 11,8 N·m
4. Reservoir Tank
5. Electric Water Pump Hose
6. Coolant Distribution Pipe
7. Battery Electric Water Pump (EWP) 2
7-a. 6.9 - 9,8 N·m

[4WD]

1. Battery Electric Water Pump (EWP) 1
1-a. 2.0 - 2,5 N·m (0.20 - 0.25 kgf·m, 1.4 - 1.8 lb·ft, 17.4 - 21.7 lb·in)
2. Motor Electric Water Pump (EWP)
2-a. 2.0 - 2,5 N·m (0.20 - 0.25 kgf·m, 1.4 - 1.8 lb·ft, 17.4 - 21.7 lb·in)
3. Reservoir Tank Bracket
3-a. 7.8 - 11,8 N·m
4. Reservoir Tank
5. Coolant Distribution Pipe
6. Electronic Water Pump Hose
7. Battery Electric Water Pump (EWP) 2 Bracket
8. Battery Electric Water Pump (EWP) 2
8-a. 6.9 - 9,8 N·m
9. Battery Electric Water Pump (EWP) 2 Bracket
9-a. 19.6 - 24 N·m

Electric Water Pump (EWP) On Vehicle Inspection

Inspection

  1. The cooling system can be more quickly diagnosed for problems using the KDS (Refer to "DTC guide").
    1. Self diagnosis : Inspect the Diagnostic Trouble Code (DTC) using the KDS (Refer to DTC guide when fault code is found.)
    Refer to the KDS screen for operating conditions and details

Electric Water Pump (EWP) Removal and Installation

Removal

  • When working on the high voltage system, the repairs should be performed by technicians who have completed the relevant training. A lack of understanding of the high voltage system can lead to serious accidents due to electric shocks or short circuit.
  • When working a high voltage system, the technician must be recognized and observe "General Safety Information and Caution". If do not follow, serious accidents like electric shock and short circuit are caused.
  • When working on high voltage system, make sure to check the Personal Protective Equipment (PPE) and high voltage shut-off procedure.
When disconnecting a quick connector, refer to the following according to the type of quick connector. - Pull the quick connector clamp (A) in the direction of the arrow to separate the clamp and remove the hose. - Do not touch the rubber seal (A) inside the hose.
  1. Drain the motor coolant. (Refer to Motor Coolant - "Drain")
  2. Remove the 3 way valve. (Refer to 3-Way Valve - "Removal and Installation")
  3. Disconnect the motor EWP connector (A).
  4. Disconnect the motor EWP cooling hose (A) after releasing the quick connector.
  5. Remove the motor EWP (A) after removing the bolts.
    Tightening torque : 2.0 - 2,5 N·m (0.2 - 0.25 kgf·m, 1.4 - 1.8 lb·ft, 17.4 - 21.7 lb·in)

Installation

  1. Install in the reverse order of removal.
  2. Perform the air bleeding procedures using the KDS after refilling the coolant. (Refer to Motor Coolant - "Refilling")
    Perform "Electric Water Pump Control" to air bleeding using KDS when filling with coolant.