Inspect battery positive ( + ) cable connection condition and repair or replace it
Discharged battery
Replace the battery according to condition after battery charge.
Engine cranks slowly
Suspected causes
Correction
Low battery charging voltage
Battery charging or replace battery
Defective connection, corroded or worn battery terminal
Inspect battery terminal or replace cable
Defective starter
Replace starter
Starter keeps running
Suspected causes
Correction
Defective starter
Replace starter
Starter running but won't engaging
Suspected causes
Correction
Wiring short circuit
Repair or replace the wiring after inspect wiring connection condition
Broken or worn pinion gear teeth or defective starter
Replace starter
Broken ring gear teeth
Replace drive plate and torque converter
Turn off the IG while driving
Suspected causes
Correction
The alternator fuse wiring is disconnection so the battery is completely discharged
Replace alternator main fuse
Inspect battery condition and repair
Defective connection of alternator connector
Inspect the connector connection
Bad restart after the engine is turned off
Suspected causes
Correction
Deterioration occurs due to poor positive ( + ) terminal contact
Replace battery wiring or Tighten at a specified torque
Engine cannot start even during the jump start
Suspected causes
Correction
Excessive parasitic current occurs irregularly due to an error in smart key registration. (Other electronic components and charging-related parts are normal.)
Reregister smart key
Defective wiring
Inspect or replace wiring
Discharged battery
Inspect or replace battery
On Vehicle Inspection
On Vehicle Inspection
Perform the inspection procedure below.
Check the starting system by cranking in the P position.
Check the starting system by cranking after inspecting the starter relay. (Refer to Starting System - "Starter Relay")
Check the starting system by cranking after inspecting the battery condition. (Refer to Charging System - "Battery")
Check List
Battery terminal connection condition
Connection condition between the battery negative ( - ) cable and the body
Inspect the starter. (Refer to Starting System - "Starter")
Inspect the starting system components and the wiring.
Check List
Connector and the wiring between the internal fuse box and the start/stop button
Connector and the wiring between the internal fuse box and the starter
Engine ground cable connection condition
Start/stop button
Stop lamp switch
Starter Specification
Specification
Item
Specification
Rated voltage (V, kW)
12, 1.2
The number of pinion teeth
13
Performance (No-load, 11 V)
Ampere (A)
Maximum 70
Speed (rpm)
Minimum 2,400
Starter Components and Components Location
Component Location
1. Starter 1-a. 49.0 - 64 N·m
Starter Description and Operation
Description
Starter consist of solenoid, brush holder, armature assembly, reduction pinion gear etc.
When the turn on the START, the current flows and is applied to the starter solenoid coil.
When supplying the current, engine is cranking after the solenoid plunger and shift lever are moved, and the reduction pinion gear inter lock to the ring gear.
To prevent damage from excessive rotation of the armature when starting, the pinion gear clutch overruns.
Starter Removal and Installation
Removal
Disconnect the battery negative ( - ) terminal.
Remove the engine compartment under cover. (Refer to Engine Mechanical System - "Engine Room Under Cover")
Disconnect the starter connector (A).
Disconnect the Oil Pressure Sensor (OPS) connector (A).
Separate the main wiring (A) after removing the fasteners.
Remove the starter B+ terminal cable (A) after removing the nut.
Tightening torque : 9.8 - 11,8 N·m
Remove the starter (A) after removing the bolts.
Tightening torque : 49.0 - 64 N·m
Installation
Install in reverse order of removal.
The starter mounting bolts should be tightened to the specified torque after pre-tightening the upper bolt and lower bolt.
If the starter is dropped, it may cause internal damage. (Do not reuse)
Starter Disassembly and Reassembly
Disassembly
Separate the solenoid M terminal (A) after removing the nut.
Tightening torque : 9.8 - 11,8 N·m
Remove the magnetic switch assembly (A) after removing the screws.
Remove the york & armature assembly (A) after removing the bolts.
Separate the lever (A) and stop lever (B).
Separate the york assembly (A), armature assembly (B) and brush holder & bracket assembly (C).
Remove the stopper (A) by using the socket (B) and rubber mallet.
Be careful not to damage the pinion gear when using a rubber mallet.
Remove the stop ring (A).
Remove the stopper (A), overrunning clutch (B) and ring gear (C).
Reassembly
Reassemble in the reverse order of disassembly.
Starter Inspection
Inspection
Magnetic Switch Inspection
Separate the solenoid M terminal (A) after removing the nut.
Tightening torque : 9.8 - 11,8 N·m
Connect the 12 V battery between the solenoid terminal and starter body.
To avoid damaging the coil, perform the test within 10 seconds.
Replace the starter when pinion gear does not move outside.
Disconnect the cable from solenoid M terminal.
To avoid damaging the coil, perform the test within 10 seconds.
The hold-in coil is normal if the pinion gear does not move to outside.
Disconnect the cable from starter body.
To avoid damaging the coil, perform the test within 10 seconds.
Replace the starter when pinion gear does not move to inside.
Connect the 12 V battery between the solenoid terminal and starter body.
To avoid damaging the coil, perform the test within 10 seconds.
Replace the starter when starter motor does not operate.
Place the starter motor in a vise equipped with soft jaws and connect a fully-charged 12 V battery to starter as follows.
Connect a test ammeter (100 A) and rheostat shown as the illustration.
Connect a voltmeter (15 V) across starter.
Rotate rheostat to the OFF position.
Connect the battery cable from the battery negative ( - ) terminal to the starter.
Adjust so that the battery voltage indicated by the voltmeter is 11 V.
Confirm that the maximum amperage is within the specifications and the starter motor turns smoothly and freely.
Ampere (A) : Maximum 70 Speed (rpm) : Minimum 2,400
Starter Motor Operation Inspection Free Running Inspection
Starter Cleaning
Cleaning
Do not immerse the yoke assembly or armature assembly in solvents as it may cause the damage in the insulation. Use a cloth to clean the parts.
Do not clean or immerse the reduction pinion gear with a solvent as it is lubricated.
All parts except the operating parts can be cleaned with a brush moistened with solvent and then wipe them with dried cloth.
Starter Relay Repair Procedures
Inspection
Disconnect the battery negative ( - ) terminal.
Remove the starter relay (A) after opening the engine room fuse box cover.
Check for continuity between the terminals (30 and 87) using an ohmmeter.
Terminal
Resistance
Measure
30 - 87
1 MΩ or higher
If there is continuity between the terminals, replace the relay.
Apply 12 V to the terminal 85 and ground to the terminal 86 and then check for continuity between the terminals (30 and 87).
Terminal
Resistance
Measure
30 - 87
1 Ω or less (About 0 Ω)
If there is no continuity between the terminals, replace the relay.