Heating,Ventilation And Air Conditioning

Components and Components Location. On Vehicle Inspection

48steps
~288min
4/5difficulty
010203040505.94N·mlb·ft
Tightening torque found on this page
Done 0 of 48

Contents:

Components and Components Location. On Vehicle Inspection

Components and Components Location

Component

1. Climate Control Air Filter Cover
2. Climate Control Air Filter
3. Blower Unit Upper Cover
4. Intake Actuator
5. Blower Motor Cover
6. Blower Motor Assembly
7. Blower Assembly

On Vehicle Inspection

On Vehicle Inspection

Diagnostic with KDS

  1. The blower system can be more quickly diagnosed for problems with the KDS (Refer to "DTC guide").
    1. Self diagnosis : Inspect the Diagnostic Trouble Code (DTC) with the KDS. (Refer to DTC guide when fault code is found.)
    Refer to the KDS screen for operating conditions and details.

Air Purification Unit Removal and Installation

Removal

  • When working on the high voltage system, the work should be performed by technicians who have completed the relevant training. A lack of understanding of the high voltage system can lead to serious accidents due to electric shock or short circuit.
  • When working on the high voltage system or related components, be sure to observe and be aware of the "Safety Precautions, Cautions and Warnings". If not, it may cause serious accidents due to electric shock or short circuit.
  • When working on the high voltage system, make sure to check the Personal Protective Equipment (PPE) and high voltage shut-off procedure.
  1. Remove the blower unit. (Refer to Heating, Ventilation And Air Conditioning - "Blower Unit - 2WD) (Refer to Heating, Ventilation And Air Conditioning - "Blower Unit - 4WD)
  2. Disconnect the air purification unit connector (A).
  3. Remove the unit (A) after removing the screws.

Installation

  • When working on the high voltage system, the work should be performed by technicians who have completed the relevant training. A lack of understanding of the high voltage system can lead to serious accidents due to electric shock or short circuit.
  • When working on the high voltage system or related components, be sure to observe and be aware of the "Safety Precautions, Cautions and Warnings". If not, it may cause serious accidents due to electric shock or short circuit.
  • When working on high voltage system, make sure to check the Personal Protective Equipment (PPE) and high voltage shut-off procedure.
  1. Install in the reverse order of removal.

Blower Motor Removal and Installation - 2WD

Removal

  • When working on the high voltage system, the work should be performed by technicians who have completed the relevant training. A lack of understanding of the high voltage system can lead to serious accidents due to electric shock or short circuit.
  • When working on the high voltage system or related components, be sure to observe and be aware of the "Safety Precautions, Cautions and Warnings". If not, it may cause serious accidents due to electric shock or short circuit.
  • When working on high voltage system, make sure to check the Personal Protective Equipment (PPE) and high voltage shut-off procedure.
  1. Remove the blower unit. (Refer to Blower - "Blower Unit")
  2. Separate the lower blower unit (A) and upper blower unit (B) after removing the screws.
    Clip position :
  3. Remove the blower motor cover (A) after removing the screws.
  4. Remove the blower motor (A) after removing the screws.

Installation

  • When working on the high voltage system, the work should be performed by technicians who have completed the relevant training. A lack of understanding of the high voltage system can lead to serious accidents due to electric shock or short circuit.
  • When working on the high voltage system or related components, be sure to observe and be aware of the "Safety Precautions, Cautions and Warnings". If not, it may cause serious accidents due to electric shock or short circuit.
  • When working on high voltage system, make sure to check the Personal Protective Equipment (PPE) and high voltage shut-off procedure.
  1. Install in the reverse order of removal.

Blower Motor Removal and Installation - 4WD

Removal

  • When working on the high voltage system, the work should be performed by technicians who have completed the relevant training. A lack of understanding of the high voltage system can lead to serious accidents due to electric shock or short circuit.
  • When working on the high voltage system or related components, be sure to observe and be aware of the "Safety Precautions, Cautions and Warnings". If not, it may cause serious accidents due to electric shock or short circuit.
  • When working on high voltage system, make sure to check the Personal Protective Equipment (PPE) and high voltage shut-off procedure.
  1. Remove the lower blower unit. (Refer to Blower - "Blower Unit")
  2. Remove the blower motor cover (A) after removing the screws.
  3. Remove the blower motor (A) after removing the screws.

Installation

  • When working on the high voltage system, the work should be performed by technicians who have completed the relevant training. A lack of understanding of the high voltage system can lead to serious accidents due to electric shock or short circuit.
  • When working on the high voltage system or related components, be sure to observe and be aware of the "Safety Precautions, Cautions and Warnings". If not, it may cause serious accidents due to electric shock or short circuit.
  • When working on high voltage system, make sure to check the Personal Protective Equipment (PPE) and high voltage shut-off procedure.
  1. Install in the reverse order of removal.

Blower Motor Inspection

Inspection

  1. Turn POWER OFF.
  2. Disconnect the blower motor connector. (Refer to Blower - "Blower Motor - 2WD") (Refer to Blower - "Blower Motor - 4WD")
  3. Apply voltage to terminal 2 and ground terminal 1 to check whether the motor is running.
    1. Ground ( - )
    2. Power ( + )
    3. Input Signal
    4. -
  4. If the old blower motor does not work, replace it with a new blower motor.

Blower Unit Removal and Installation - 2WD

Removal

  • When working on the high voltage system, the work should be performed by technicians who have completed the relevant training. A lack of understanding of the high voltage system can lead to serious accidents due to electric shock or short circuit.
  • When working on the high voltage system or related components, be sure to observe and be aware of the "Safety Precautions, Cautions and Warnings". If not, it may cause serious accidents due to electric shock or short circuit.
  • When working on the high voltage system, make sure to check the Personal Protective Equipment (PPE) and high voltage shut-off procedure.
  1. Remove the front trunk. (Refer to Body - "Front Trunk")
  2. Disconnect the intake actuator connector (A) and the blower motor connector (B) after removing the fasteners.
    Clip position :
  3. Remove the blower unit (A) after removing the nuts.
    Tightening torque : 3.9 - 5,9 N·m (0.4 - 0.6 kgf·m, 2.9 - 4.3 lb·ft, 34.7 - 52.1 lb·in)

Installation

  • When working on the high voltage system, the work should be performed by technicians who have completed the relevant training. A lack of understanding of the high voltage system can lead to serious accidents due to electric shock or short circuit.
  • When working on the high voltage system or related components, be sure to observe and be aware of the "Safety Precautions, Cautions and Warnings". If not, it may cause serious accidents due to electric shock or short circuit.
  • When working on the high voltage system, make sure to check the Personal Protective Equipment (PPE) and high voltage shut-off procedure.
  1. Install in the reverse order of removal.

Blower Unit Removal and Installation - 4WD

Removal

  • When working on the high voltage system, the work should be performed by technicians who have completed the relevant training. A lack of understanding of the high voltage system can lead to serious accidents due to electric shock or short circuit.
  • When working on the high voltage system or related components, be sure to observe and be aware of the "Safety Precautions, Cautions and Warnings". If not, it may cause serious accidents due to electric shock or short circuit.
  • When working on high voltage system, make sure to check the Personal Protective Equipment (PPE) and high voltage shut-off procedure.
  1. Remove the front high voltage junction box. (Refer to Battery Control System - "Front High Voltage Junction Box")
  2. Disconnect the intake actuator connector (A) and separate the fastener (B).
  3. Remove the blower unit screws (A).
  4. Remove the upper blower unit (A) after removing the nuts.
    Tightening torque : 3.9 - 5,9 N·m (0.4 - 0.6 kgf·m, 2.9 - 4.3 lb·ft, 34.7 - 52.1 lb·in)
  5. Disconnect the blower motor connector (A) and separate the fastener (B).
  6. Remove the lower blower unit (A) after removing the nuts.
    Tightening torque : 3.9 - 5,9 N·m (0.4 - 0.6 kgf·m, 2.9 - 4.3 lb·ft, 34.7 - 52.1 lb·in)

Installation

  • When working on the high voltage system, the work should be performed by technicians who have completed the relevant training. A lack of understanding of the high voltage system can lead to serious accidents due to electric shock or short circuit.
  • When working on the high voltage system or related components, be sure to observe and be aware of the "Safety Precautions, Cautions and Warnings". If not, it may cause serious accidents due to electric shock or short circuit.
  • When working on high voltage system, make sure to check the Personal Protective Equipment (PPE) and high voltage shut-off procedure.
  1. Install in the reverse order of removal.

Climate Control Air Filter Description and Operation

Description

The air filter for the air conditioner installed on the blower unit removes foreign substances or odors. The particle filter not only removes general dust but also serves as a odor-removing filter to maintain a comfortable indoor environment.

Climate Control Air Filter Replacement

Replacement

[2WD]
  1. Open the front trunk (A).
  2. Remove the service cover (A).
  3. Remove the air filter cover (A) for air conditioner by pressing the filter cover knob in the direction of the arrow.
  4. Replace the air conditioner air filter (A).
  5. Install in the reverse order of removal.
    • Replace the air filter for air conditioning according to the replacement interval of the instruction manual.
    • When driving in an area with severe air pollution or an area where a lot of fumes are generated due to poor road conditions, frequent inspections and replacements are required.
  6. Open the front trunk (A).
  7. Remove the service cover (A).
  8. Remove the air filter cover (A) for air conditioner by pressing the filter cover knob in the direction of the arrow.
  9. Replace the air conditioner air filter (A).
  10. Install in the reverse order of removal.
    • Replace the air filter for air conditioning according to the replacement interval of the instruction manual.
    • When driving in an area with severe air pollution or an area where a lot of fumes are generated due to poor road conditions, frequent inspections and replacements are required.
[4WD]

Intake Actuator Description and Operation

Description

It is operated by a heater control unit and controls the position of the intake door to adjust the fresh air mode / recirculation mode.

Intake Actuator Removal and Installation - 2WD

Removal

  • When working on the high voltage system, the work should be performed by technicians who have completed the relevant training. A lack of understanding of the high voltage system can lead to serious accidents due to electric shock or short circuit.
  • When working on the high voltage system or related components, be sure to observe and be aware of the "Safety Precautions, Cautions and Warnings". If not, it may cause serious accidents due to electric shock or short circuit.
  • When working on high voltage system, make sure to check the Personal Protective Equipment (PPE) and high voltage shut-off procedure.
  1. Remove the blower unit. (Refer to Blower - "Blower Unit")
  2. Separate the upper blower unit (B) and lower blower unit (A) after removing the screws.
    Clip position :
  3. Remove the blower unit upper cover (A) after removing the screws.
  4. Remove the intake actuator (A) after removing the screws.

Installation

  • When working on the high voltage system, the work should be performed by technicians who have completed the relevant training. A lack of understanding of the high voltage system can lead to serious accidents due to electric shock or short circuit.
  • When working on the high voltage system or related components, be sure to observe and be aware of the "Safety Precautions, Cautions and Warnings". If not, it may cause serious accidents due to electric shock or short circuit.
  • When working on high voltage system, make sure to check the Personal Protective Equipment (PPE) and high voltage shut-off procedure.
  1. Install in the reverse order of removal.

Intake Actuator Removal and Installation - 4WD

Removal

  • When working on the high voltage system, the work should be performed by technicians who have completed the relevant training. A lack of understanding of the high voltage system can lead to serious accidents due to electric shock or short circuit.
  • When working on the high voltage system or related components, be sure to observe and be aware of the "Safety Precautions, Cautions and Warnings". If not, it may cause serious accidents due to electric shock or short circuit.
  • When working on high voltage system, make sure to check the Personal Protective Equipment (PPE) and high voltage shut-off procedure.
  1. Remove the upper blower unit. (Refer to Blower - "Blower Unit")
  2. Remove the blower unti upper cover (A) after removing the screws.
  3. Remove the intake actuator (A) after removing the screws.

Installation

  • When working on the high voltage system, the work should be performed by technicians who have completed the relevant training. A lack of understanding of the high voltage system can lead to serious accidents due to electric shock or short circuit.
  • When working on the high voltage system or related components, be sure to observe and be aware of the "Safety Precautions, Cautions and Warnings". If not, it may cause serious accidents due to electric shock or short circuit.
  • When working on high voltage system, make sure to check the Personal Protective Equipment (PPE) and high voltage shut-off procedure.
  1. Install in the reverse order of removal.

Intake Actuator Inspection

Inspection

  1. Turn POWER OFF.
  2. Disconnect the intake actuator connector.
  3. Apply voltage to the intake actuator 1 terminal and ground the 2 terminal to check whether the actuator operates.
  4. When connecting in the opposite, check if it operates in reverse.
    1. Recirculated Air
    2. Fresh Air
    3. -
    4. Sensor Ground
    5. Feedback Signal
    6. Sensor Power (+5 V)
  5. Connect the intake actuator connector.
  6. POWER ON.
  7. Measure the terminal voltage between 5 and 6.
    Door Position Voltage (V) Error Detection
    Fresh air 0.35 - 0.65 Low voltage : less than 0.1 V
    High voltage : more than 4.9 V
    Recirculation 4.35 - 4.65
  8. If the measured voltage does not match with the specification, replace it with a new intake actuator.