Battery Control System (Standard)
High Voltage Charging System
In this manual: Battery Control System (Standard)
89steps
~534min
4/5difficulty
Done 0 of 89
Contents:
Description and Operation
Description
- The high voltage charge used in an EV was a system that boosted the voltage internally through an existing On-Board Charger (OBC), but the latest system is a multi charge system that charges the high voltage battery to 800 V even if there is a difference in the voltage during normal charging or quick charging.
- The multi quick charging system is a system supplied to existing infrastructure and is a system that charges to a high voltage of 800 V using the 400 V charging system used for normal charging or quick charging.
- The Battery Management Unit (BMU) controls the charging performance and speed according to the charging current by receiving the temperature signal in the battery.
- The driver can charge the battery depending on the situation, conveniently, regardless of the charging facilities or equipment. It can be charged to DC 800 V through a self-boosting process by using the multi inverter in the vehicle.
- In the case of EV6, a DC 800 V high-voltage charging system is applied as standard, which sharply reduces charging time. When using a quick charger, you can drive more than 100 km with a short charge of less than 4 minutes and 30 seconds (based on WLTP), and the battery can be charged from 10% to 80% in 18 minutes.
- When normal charging with a 400 V system, a quick charge relay is used for the self-boosting process. The voltage is converted through the multi inverter and charges to a high voltage battery.
- The high voltage charging system consists of the Integrated Charging Control Unit (ICCU), Vehicle Charge Management System (VCMS), Charger Inlet Assembly, etc.
- Protect the safety and system through cooperative control.
- When multi charging, a fail-safe mode is applied to increase compatibility during the existing 400 V charging and 800 V charging, and for safety reasons, the vehicle cannot be driven, and it cannot charge the quick and normal at the same time.
Function
- Normal Charging : The AC power (220 V) of normal charger is converted to DC power through the Integrated Charge Control Unit (ICCU) to charge the high voltage battery.
- Multi-Input Quick Charging : It charges the high voltage battery with the DC power of the quick charger. - The multi-inverter assembly allows charging regardless of the quick charger type (400 V / 800 V). (No additional converter required) - When charging with a 400 V charger, the high voltage battery is charged after boosting the voltage to 800 V using a multi-inverter. - The information about vehicle condition during charging controls the whole process of charging through CAN communication and the control unit related charging connected to the Vehicle Charging Management System (VCMS).
- V2L (Vehicle to Load) : It provides general electric power (110 V / 220 V) inside and outside the vehicle through the bidirectional OBC. 1. How to use - Outdoor V2L : Available after connecting the V2L gender connector to the charger inlet. - Indoor V2L : Available in POWER ON or utility mode 2. System Configuration Diagram
- V2V (Vehicle-to-Vehicle) : It is possible to charge between vehicles by using a two-way OBC. 1. How to use - It can be charged by connecting the charging cable (ICCB) to V2L gender after connecting the V2L gender to the charger Inlet.
- Plug and Charge (PnC) : Charging can be done immediately without additional authentication / payment process by using VCMS.
Charging System Flow Diagram
The components for controlling the high voltage charging system- Vehicle Charging Management System (VCMS)
- Integrated Charging Control Unit (ICCU)
- Multi Inverter Assembly
- Charge & Inlet Lock System
- Battery Management System
- Vehicle Control Unit (VCU)
- In-Cable Control Box (ICCB) : This is the cable for charging between vehicles in an emergency.
On Vehicle Inspection
On Vehicle Inspection
|
How to inspect when charging is not working
- Check Charging Warning Message
- Perform the normal charge for approximately 10 minutes by using the Electric Vehicle Charging Equipment (EVSE) that operates normally.
- If the charge is not operated, check the charge warning message with POWER ON.
The charge warning messages are displayed for 10 seconds in the cluster and 3 seconds in the AVN. - When cluster message is displayed, check it as follows.
Warning Message Suspected Cause How to inspect Check the external (normal/fast) charger condition. • EVSE Control Pilot (CP) signal fault
• EVSE Charging Interruption (Self Diagnostic / User Shutdown, etc.)
• Power shut off or breaker operation• Check for the EVSE abnormality
• Inspect the VCMS when the same warning message is displayed in other EVSECheck the charge connector connection condition. • Charge cable connector faulty connection • Inspect charge cable (foreign substance, damage)
• Inspect the VCMS (proximity detection signal inspection) when the same warning message is displayed after the replacing the charging cable
- Vehicle Condition Inspection
- Check the conditions for normal charging and inspect them as follows.
Item Operating condition How to inspect Reservation charging • Reservation charging OFF
• Press the cancel button with the reservation charging set (only available within 3 minutes of the charging cable connection)
• When the charging start time is reached in the state with reservation charging set• Set the reservation charging OFF in the AVN, perform the charging Target charge level setting • When target charge level is more than the current high voltage battery SOC • Set the charge limit in the AVN to 100%, perform the charging Gear position • P range • Charging in P range Low voltage (12 V) battery • Normal • Charging at normal low voltage (12 V) battery battery conditions
- Check the conditions for normal charging and inspect them as follows.
How to inspect when V2L is not working
- Check Discharging Warning Message
- Connect the V2L gender and perform the V2L function for about 5 minutes.
- If the discharge is not operated, check the discharge warning message in POWER ON.
The discharge warning messages are displayed for 10 seconds in the cluster and 3 seconds in the AVN. - When cluster message is displayed, check it as follows.
Warning Message Suspected Cause How to inspect V2L turns off, as battery discharge limit has been reached. • Discharge power exceeded • Inspect electronic devices V2L operation conditions not met. • V2L gender switch turned off
• Indoor V2L outlet overheated
• Charge door is opened while using indoor V2L• Inspect V2L gender (foreign substance, damage)
• Inspect Indoor V2L outlet
• Inspect charge door assembly
- Vehicle Condition Inspection
- Check the V2L operation conditions and inspect them as follows.
Item Operating condition How to inspect Set the limit of discharging • When discharge limit is lower than the current high voltage battery SOC • Set the discharge limit in the AVN to 20%, perform the discharging lLow voltage (12 V) battery • Normal • Perform the auxiliary 12 V battery discharge in normal condition
- Check the V2L operation conditions and inspect them as follows.
Charge Door Actuator Removal and Installation
Removal
- Remove the outside rear combination lamp [passenger]. (Refer to Body - "Rear Combination Lamp")
- Remove the flange cover bracket (A) after removing the screws.
- Remove the flange cover (A) after removing the screws.
- Disconnect the charge door control unit connector (A).
- Remove the stop lamp & tail lamp (A) after removing the screws.
- Disconnect the charge door actuator connector (A).
- Remove the charge door actuator (A) after removing the screws.
Installation
- Install in the reverse order of removal.
If charge door actuator is dropped, it may cause internal damage. (Do not reuse) - After replacing the charge door actuator and the related parts, vehicle should be checked that it charges normally.
Charge Door Assembly Removal and Installation
Removal
- Remove the outside rear combination lamp [passenger]. (Refer to Body - "Rear Combination Lamp")
- Remove the flange cover bracket (A) after removing the screws.
- Remove the flange cover (A) after removing the screws.
- Disconnect the charge door control unit connector (A).
- Remove the stop lamp & tail lamp (A) after removing the screws.
- Remove the turn signal lamp (A) after removing the screws.
- Remove the rear bumper side garnish(A) after releasing the hooks.
Installation
- Install in the reverse order of removal.
If charge door assembly is dropped, it may cause internal damage. (Do not reuse) - After replacing the charge door assembly and the related parts, vehicle should be checked that it charges normally.
Charge Door Switch Replacement
Replacement
| The charge door switch cannot be replaced individually due to included in the crash pad switch. If necessary, replace the crash pad switch. |
- Replace the crash pad switch. (Refer to Body - "Crash Pad Switch")
Charge Junction Box Unit Removal and Installation
Removal
|
- Perform the high voltage shut off procedure. (Refer to Battery Control System - “High Voltage Shut-off Procedure”)
- Remove the rear floor carpet. (Refer to Body - "Floor Carpet Assembly")
- Disconnect the charger inlet connector (A) and charge junction box control connector (B).
- Disconnect the AC charge connector (A)and removing the fasteners.
- Remove the charge Junction box Unit (A) after removing the nuts.
Tightening torque : 9.8 - 11,8 N·m
Installation
|
- Install in the reverse order of removal.
- Install the charge junction box unit to the specified torque.
- If charge junction box unit is dropped, it may cause internal damage. (Do not reuse)
- After replacing the charge door assembly and the related parts, vehicle should be checked that it charges normally.
Charger Inlet Assembly Components and Components Location. Charger Inlet Assembly Description and Operation
Charger Inlet Assembly Components and Components Location
Component
| 1. Rear Combination Lamp 2. Charge Door Assembly 3. Service Cover 3-a. 4.9 - 7,8 N·m (0.5 - 0.8 kgf·m, 3.6 - 5.8 lb·ft, 43.4 - 69.4 lb·in) |
4. Charger Inlet Assembly 4-a. 9.3 - 10,3 N·m 4-b. 10.8 - 13,7 N·m 4-c. 6.9 - 9,8 N·m |
Charger Inlet Assembly Description and Operation
Description
- Charging starts when the In-Cable Control Box (ICCB) is connected to the normal charge port or the quick charge connector is connected to a quick charge port.
- The charger inlet assembly can charge the vehicle regardless of the charging method (AC or DC).
- Quick DC : It is connected to rear multi inverter, and controls the multi charge relay depending on the voltage.
- Normal AC : It is connected Integrated Charging Control Unit (ICCU), and controls the main relay by Battery Management Unit (BMU).
- The normal and quick charges are separated by the conversion of the duty ratio through the CP line between the Vehicle Charge Management System (VCMS) and the charger.
- The temperature sensor is installed in the charge inlet assembly, and it cuts off the charging when the temperature is over a certain during charging.
Charger Inlet Assembly Removal and Installation
Removal
|
- Perform the high voltage shut off procedure. (Refer to Battery Control System - “High Voltage Shut-off Procedure”)
- Remove the rear floor carpet. (Refer to Body - "Floor Carpet Assembly")
- Remove the outside rear combination lamp [passenger]. (Refer to Body - "Rear Combination Lamp")
- Remove the quick charge connector service cover (A) after removing the nuts.
Tightening torque : 4.9 - 7,8 N·m (0.5 - 0.8 kgf·m, 3.6 - 5.8 lb·ft, 43.4 - 69.4 lb·in) - Disconnect the quick charge connector (A) after releasing the bolt.
Tightening torque : 9.3 - 10,3 N·m
quick charge connector bolt (A) cannot be completely removed. - Separate the cable fixing clip (A).
- Remove the wiring (A) after disconnecting the connector and removing the fasteners.
- Disconnect the charger inlet assembly connector (A) and charger inlet assembly control connector (B).
- Disconnect the charger inlet assembly wiring (A) after removing the fasteners.
- Remove the ground cable (A) after removing the bolt.
Tightening torque : 10.8 - 13,7 N·m
- Disconnect the connector (A).
- Remove the rear cross member under cover. (Refer to Motor and Reduction Gear System - "Rear Under Cover")
- Remove the rear under cover (A).
- Disconnect the charger inlet assembly (A) from the body frame after removing the fasteners and nuts.
Tightening torque : 4.9 - 7,8 N·m (0.5 - 0.8 kgf·m, 3.6 - 5.8 lb·ft, 43.4 - 69.4 lb·in) - Remove the charger inlet assembly (A) after removing the bolts.
Tightening torque : 6.9 - 9,8 N·m
Installation
|
- Install in the reverse order of removal.
- Install the charger inlet assembly to the specified torque.
- Damaged cable should be replaced with new ones. (Do not reuse or repair)
- After replacing the charger inlet assembly and the related parts, vehicle should be checked that it charges normally.
In-Cable Control Box (ICCB) Specification
Specification
| Item | Specification |
| Rated voltage (V) | 120 - 230 |
| Rated current (A) | 6, 8, 10, 12 (Variable Settings) |
In-Cable Control Box (ICCB) Description and Operation
Description
- A device designed to provide assistance with AC charging (at home).
- The ICCB has functions such as indicating the state of charge, blocking and detecting leakage current, blocking power when the internal temperature is abnormal, detecting over-current, blocking power plug when the temperature is abnormal, and automatically varying current down.
Indicator Description
| Name | Indicator | Function |
| POWER indicator | Illuminates green when the power plug is connected | |
| CHARGE indicator | - Illuminates blue during AC charging - Blinks blue during charging with lower current |
|
| FAULT indicator | Blinks red when charging stops due to a failure (e.g., leakage current or over current) | |
| 7 - segment | - Displays charging current or DTC - Blinks in charging current selection mode |
In-Cable Control Box (ICCB) Troubleshooting
Troubleshooting
The lighting of a display signal when charging is proceeding as normal| Order | Condition | Display Mode | |
| 1 | Connecting the ICCB to the power plug : Power indicator light up and the charging current that is set is displayed in the 7- segment. | Standby mode | |
| 2 | ICCB connection to the vehicle's inlet and charging : If the ICCB is connected to the inlet connector, the ICCB performs a self-examination for approximately 1.5 seconds, and if there are no problems, it activates ON the internal relay, thereby becoming able to charge, and the charge indicator lights up (charging satus). In charging status, if there are no changes for approximately 1 minute, the 7- segment charging current display turns OFF in order to enter sleep mode. If the plug temperature is 80 - 90 °C, or the internal temperature of the ICCB is 90 - 95 °C, it enters the lowering mode of the charging current and the charging current becomes 6 A, making the charging indicator keep flashing ON and OFF. If after the lowering of mode of the charging current the temperature falls below 70 °C, the original charging current value is restored. |
Charging mode | |
| 3 | Charging completed : Charge indicator goes OFF and only the power indicator lights green | Standby mode | |
How to set the charging current
| Order | Procedure |
| 1 | Entering the state of charge current setting Pressing the button in the standby or charged state for 2 to 8 seconds will enter the charging current setting state and the charging current value in the 7- segment will flash. |
| 2 | Change the charging current The charging current is initially set at 6 A and is raised by one step each time the button is pressed (less than 1 second). When the current set value is 12 A, press the button to change to 6 A. Level 1 : 6 A → Level 2 : 8 A → Level 3 : 10 A → Level 4 : 12 A → Level 1 : 6 A |
| 3 | Determining the charging current After setting the charging current, pressing the button for more than one second changes to the set value and switches from the charging current setting mode to the original mode (standby mode or charging mode). When there is no button input, it is returned to the previously set charging current value and switched to the original mode. |
In Cable Control Box (ICCB) Self-diagnosis
The ICCB operation if there is a fault
| The ICCB operation if there is a fault | Display Mode | |
| The power indicator lights ON, the fault indicator flashes, and the fault code for the 7- segment lights ON. The power is turned OFF with the OFF of the internal relay. | Fault mode | |
Fault code list of In Cable Control Box (ICCB)
| Fault Code | Item | Suspected Cause | Inspection |
| E1 | CP communication | Vehicle communication fault occurred | Inspect the communication line and the ICCU |
| E2 | Leakage | Leakage current occurred | E2 fault code (leaking current) remedy method: remove the power plug and press the button for more than 2 seconds after reconnecting. ※ Repeat the procedures above 2 to 3 times and if the problem is not resolved, replace the ICCB. |
| E3 | Charger fault Occurred | Replace the ICCB | |
| E4 | Plug temperature | Power plug temperature 90 °C or more | |
| E5 | Power plug temperature rise more than 20 °C within 1 minute | ||
| E6 | Power plug temperature sensor fault | ||
| E7 | Overcurrent | Charge overcurrent warning | |
| E8 | Internal temperature | ICCB internal temperature 95 °C or more | |
| E9 | ICCB internal temperature sensor fault | ||
| F1 | Relay fault | Internal relay weld | |
| F3 | SMPS power fault | SMPS output voltage 8.5 V or less | |
| F4 | SMPS output voltage 8.5 - 11 V | ||
| F5 | CP voltage fault | CP ( - ) voltage fault | |
| F6 | CP ( + ) voltage fault | ||
| F7 | Temperature sensor fault | Plug temperature sensor fault | |
| F8 | PCB internal temperature sensor fault |
How to delete the past fault codes
| Order | Condition | Display Specification |
| Fault code call | The fault code call is possible when there is no fault indication in the standby mode. In order to call the history of past faults, press the button for more than 8 seconds. | |
| Deleting the saved fault code | After calling the fault code, if the button is pressed for more than 8 seconds, the fault code is deleted, and in the 7- segment, "NO" is indicated. Afterwards, it enters the automatic standby mode. | |
| Restore the standby mode | The method of returning to the original state without deleting the fault code
|
Inlet Actuator Description and Operation
Description
- The inlet actuator prevents the vehicle connector from disengaging during charging.
- The inlet actuator is restricted based on the door lock status. If the door is open, the vehicle connector must be removed within 15 seconds. If this time limit is exceeded, it will return to the locked state.
- In case of a malfunction of the inlet actuator, only slow charging is possible. Quick charging or V2L will not function.
Operating Principle
- When the inlet actuator detects the attachment of the vehicle connector, it transmits a signal to the Vehicle Charge Management System (VCMS).
- The VCMS operates the charging station locking and unlocking relay inside the PE room.
- The inlet actuator is operational.
Inlet Actuator Removal and Installation
Removal
|
- Perform the high voltage shut off procedure. (Refer to Battery Control System - “High Voltage Shut-off Procedure”)
- Remove the passenger luggage side trim. (Refer to Body - "Luggage Side Trim")
- Remove the outside rear combination lamp [passenger]. (Refer to Body - "Rear Combination Lamp")
- Remove the charger inlet assembly (A) after removing the bolts.
Tightening torque : 6.9 - 9,8 N·m
- Disconnect the inlet actuator connector (A).
- Separate the inlet actuator cable (A).
- Remove the inlet actuator (A) after removing the screws.
Installation
|
- Install in the reverse order of removal.
If inlet actuator is dropped, it may cause internal damage. (Do not reuse) - After replacing the inlet actuator and the related parts, vehicle should be checked that it charges normally.
Integrated Charging Control Unit (ICCU) Specification
Specification
| Item | Specification | |
| Function | On-Board Charger (OBC) + Low Voltage DC/DC Converter (LDC) | |
| OBC system specification | Capacity (kW) | 10.9 |
| Input voltage (V) | AC 70 - 285 | |
| Output voltage (V) | DC 360 - 845 | |
| Input current (A) | Maximum 48 | |
| LDC system specification | Maximum capacity (kW) | 2.567 |
| Input voltage (V) | DC 288 - 845 | |
| Output voltage (V) | 7 - 16 | |
| Ampere (A) | 170 | |
| Cooling | Cooling type | Water cooling |
| Operating temperature [°C (°F)] | -40 to 85 (-40 to 185) | |
Integrated Charging Control Unit (ICCU) Components and Components Location
Component
| 1. Cooling hoses 2. Low Voltage DC/DC Converter (LDC) Positive ( + ) Cable 2-a. 7.8 - 9,8 N·m 3. Integrated Charge Control Unit (ICCU) Connector 4. ICCU High Voltage Power Cable |
5. LDC Negative ( - ) Cable 5-a. 7.8 - 9,8 N·m 6. Charger Inlet Connector 7. ICCU 7-a. 19.6 - 24 N·m |
| 1. Integrated Charge Control Unit (ICCU) Pad 1-a. 3.9 - 5,9 N·m (0.4 - 0.6 kgf·m, 2.9 - 4.3 lb·ft, 34.7 - 52.1 lb·in) 2. Low Voltage DC/DC Converter (LDC) Negative ( - ) Cable 2-a. 10.8 - 13,7 N·m 2-b. 7.8 - 9,8 N·m |
3. ICCU 3-a. 19.6 - 24 N·m |
Integrated Charging Control Unit (ICCU) Description and Operation
Description
- The Integrated Charging Control Unit (ICCU) was previously referred to as the On-Board Charger (OBC). Its role was simply to step up the AC 220V voltage supplied to the charging port to a voltage suitable for the high-voltage battery. The ICCU applied to the EV6 performs three functions.
- Stepping up the 220V supplied through the charging port during slow charging to the battery charging voltage of 800V.
- Providing the On-Board Charger (OBC) function to supply 220V power for indoor and outdoor V2L (Vehicle to Load).
- Converting the high-voltage battery power to a lower power to charge the low voltage (12 V) battery, functioning as a Low Voltage DC/DC Converter (LDC).
- ICCU is an integrated unit consisting of a bidirectional OBC and a LDC. 1) OBC - The OBC converts AC voltage to DC voltage to supply power to the high voltage battery. - It converts high-voltage battery power, which is DC voltage, into AC voltage to supply power (110V / 220V) inside or outside the vehicle. 2) LDC - Converts the power (High DC) of the high voltage battery to the low voltage (12 V) battery power (Low DC). (High voltage → Low voltage)
Low Voltage DC/DC Converter (LDC) system
- The Low Voltage DC/DC Converter (LDC) is a converter.
- This is a system designed to step down the power from a high-voltage battery to DC power for use in V2L (Vehicle-to-Load).
- Since electric vehicles lack generators, converting high voltage to low voltage is necessary to charge the low voltage (12 V) battery. Therefore, LDC is used to transform the high voltage of 800V to 12V.
On-Board Charger (OBC) system
- The On-Board Charger (OBC) is capable of bidirectional conversion. (AC↔DC)
- It controls the switching control and timing of the inverter through by control unit.
- The primary AC voltage is boosted to DC voltage and controlled for power factor correction, through which the controlled for boosting during 220V slow charging.
- It converts DC voltage to AC voltage to supply power to V2L.
- When using the V2L function, it supplies power to household appliances conveniently by converting DC to AC through secondary voltage reduction.
- DC/DC converter inside the OBC is converted to DC by the AC/DC converter during charging.
- It controls the output voltage through the internal DC/DC converter.
- The AC/DC converter is composed of an EMI filter and a PFC converter.
- EMI Filter : It is a filter for remove the high frequency noise caused by input voltage.
- PFC Converter : It is a converter used to compensate for power factor when converting AC voltage to DC voltage.
LDC and OBC Control system Composition
Integrated Charging Control Unit (ICCU) Troubleshooting
Troubleshooting
How to remedy when the fault code occurs
On-Board Charger (OBC)| Item | Major Fault Code | Suspected Cause | Inspection |
| OBC inspection | • Internal sensor fault (voltage, current, temperature) • OBC output power performance abnormal |
• OBC | • Check the OBC temperature change during charging, replace the Integrated Charge Control Unit (ICCU) if the same fault code occurs after performing the normal charge |
| Vehicle inspection | • OBC overheat | • Coolant system • Low coolant • Electric Water Pump (EWP) |
• Check the OBC temperature change during charging • Inspect the Electric Water Pump (EWP) |
| • Interlock | • High voltage cable | • Check the high voltage DC connector connection and terminal condition | |
| • Battery charger output voltage low • High voltage battery voltage and OBC output voltage deviation high |
• High voltage cable • OBC fuse (high voltage battery) |
• Check the high voltage DC connector connection and terminal condition • Replace the ICCU |
|
| Inspect external AC power | • Battery charger input voltage low • Battery charger input voltage high |
• External AC power system • EVSE • High voltage cable • OBC |
• Check the Electric Vehicle Charging Equipment (EVSE) and external AC power (voltage, frequency) • Inspect the vehicle wire if the same fault code occurs after performing the charge by using the Electric Vehicle Charging Equipment (EVSE) that operates normally • Replace the ICCU if the same fault code occurs after vehicle wire check |
| V2L load inspection | • V2L mode AC output overload | • Using high load electrical product • V2L connector • Indoor V2L outlet • OBC |
• Perform the V2L without the electrical product connection - DTC occurred : Vehicle inspection required - No DTC : Overload caused by previously used electrical products |
Low Voltage DC/DC Converter (LDC)
| Item | Major Fault Code | Suspected Cause | Inspection |
| LDC inspection | • Output overvoltage fault | • LDC | • Replace the Integrated Charge Control Unit (ICCU) when the same problem occurs after the vehicle restarts |
| • LDC Voltage Control fault | |||
| • Sensors fault - Current sensor offset calibration abnormality - Temperature sensor open circuit/short circuit/performance abnormality fault - Input / Output voltage sensor fault |
|||
| • PWM output fault | |||
| Vehicle inspection | • Output terminal path fault | • Wiring and connectors between the LDC output terminal and the high voltage junction box | • Check the LDC output circuit and cable connection condition |
| Coolant system fault | • Coolant system • Low coolant • Electric Water Pump (EWP) |
• Inspect the Electric Water Pump (EWP) | |
| • Input over current fault | • low voltage (12 V) battery discharged • 12 V electric component overload |
• Check the low voltage (12 V) battery discharge condition • Check abnormal operation or short circuit conditions of 12 V electric components |
Integrated Charging Control Unit (ICCU) Removal and Installation
Removal
|
- Perform the high voltage shut off procedure. (Refer to Battery Control System - “High Voltage Shut-off Procedure”)
- Drain the coolant. (Refer to Cooling System - "Motor Coolant")
- Remove the rear seat assembly. (Refer to Body - "Rear Seat Assembly")
- Disconnect the charge inlet connector (A).
- Remove the Low Voltage DC/DC Converter (LDC) negative ( - ) cable (A) after removing the bolt.
Tightening torque : 7.8 - 9,8 N·m
- Disconnect the Integrated Charge Control Unit (ICCU) power cable connector (A).
- Disconnect the ICCU connector (A).
- Remove the LDC positive ( + ) cable (A) after removing the bolt.
Tightening torque : 7.8 - 9,8 N·m
- Disconnect the cooling hose connectors (A).
- Remove the ICCU (A) after removing the bolts.
Tightening torque : 19.6 - 24 N·m
- Remove the ICCU pad (A).
Tightening torque : 3.9 - 5,9 N·m (0.4 - 0.6 kgf·m, 2.9 - 4.3 lb·ft, 34.7 - 52.1 lb·in) - Perform the high voltage shut off procedure. (Refer to Battery Control System - “High Voltage Shut-off Procedure”)
- Disconnect the Integrated Charge Control Unit (ICCU) connector (A).
How to disconnect the connector - Release the locking clip (A) by pulling it.
- Disconnect the connector while pressing the locking clip (B).
- Remove the ICCU fuse service cover (A) after removing the bolts.
Tightening torque : 7.8 - 11,8 N·m
- Remove the ICCU fuse cover (A) after removing the bolts.
Tightening torque : 2.5 - 3,3 N·m (0.26 - 0.34 kgf·m, 1.9 - 2.5 lb·ft, 22.6 - 29.5 lb·in) - Remove the ICCU fuse (A) after removing the bolts.
Tightening torque : 4.4 - 5,4 N·m (0.45 - 0.55 kgf·m, 3.3 - 4.0 lb·ft, 39.1 - 47.7 lb·in)
Installation
|
- Install in the reverse order of removal.
- Install the Integrated Charging Control Unit (ICCU) to the specified torque.
- If the ICCU and ICCU fuse are dropped, it may cause internal damage. (Do not reuse)
- Replace the ICCU fuse cover with a new one. (Do not reuse)
- Refill with coolant. (Refer to Cooling System - "Motor Coolant")
- After replacing the ICCU and the related parts, vehicle should be checked that it charges normally.
Vehicle Charge Management System (VCMS) Specification. Vehicle Charge Management System (VCMS) Components and Components Location
Vehicle Charge Management System (VCMS) Specification
Specification
| Item | Specification |
| Rated voltage (V) | DC 11 - 13 |
| Operating voltage (V) | DC 9 - 16 |
| Operating temperature [°C (°F)] | -30 to 85 (-22 to 185) |
| Parasitic current (mA) | Maximum 1.0 (Power off Mode) |
Vehicle Charge Management System (VCMS) Components and Components Location
Component Location
| 1. Vehicle Charge Management System (VCMS) bracket 1-a. 6.9 - 9,8 N·m |
2. VCMS 2-a. 9.8 - 11,8 N·m |
Vehicle Charge Management System (VCMS) Description and Operation
Description
Function
- Performs integrated control of charging-related control functions distributed in multiple controllers.
- It controls the normal/quick charging interface and the convenience functions interface.
Control logic
| * V2G (Vehicle to Grid) : It is the bidirectional charging/discharging sequence with standard-based charging communication and vehicle cooperation control. * V2L (Vehicle to Load) : It provides electric power (110 V / 220 V) indoor and outdoor the vehicle by converting the DC power of the high voltage battery into AC power. * V2V (Vehicle to Vehicle) : Vehicle to vehicle communication (charging) function * PnC (Plug and Charge) : Charging can be done immediately without additional authentication / payment process. * PLC (Power Line Communication) * EVSE (Electric Vehicle Supply Equipment) * OBC (On-Board Charger) |
Composition
It consists of CMS and PCM. (Configure two CPUs on one control board)- CMS (Charging Management System) : It controls cooperation with related controllers for charging, V2G, V2L, and convenience functions. (overall control of charging)
- PCM (Powerline Communication Module) : It controls charging/vehicle communication and security functions for PLC communication, PnC, and connectivity functions.
Vehicle Charge Management System (VCMS) Troubleshooting
Troubleshooting
How to remedy when the fault code occurs
| Check the EVSE, charger inlet assembly, quick charge relay and related controller before replacing the Vehicle Charging Management System (VCMS). |
| Item | Major Fault Code | Suspected Cause | Inspection |
| Vehicle Charge Management System (VCMS) |
• System over voltage and low voltage • Control module (CPU) performance abnormal |
• VCMS • Low voltage (12 V) battery |
• If the same fault occurs after performing the normal / quick charge, check the low voltage (12 V) battery and replace the VCMS |
| • Proximity Detection (PD) circuit fault | • VCMS • Check the wiring and connector between the charger inlet terminal and the VCMS |
• Check the VCMS PD recognition circuit • Wiring and connector fault between the charger inlet terminal and the VCMS |
|
| Electric Vehicle Supply Equipment (EVSE) |
• EVSE Control Pilot (CP) signal fault | • EVSE | • Check the VCMS CP recognition circuit if the same fault code occurs after performing the charge by using the Electric Vehicle Charging Equipment (EVSE) that operates normally |
| • EVSE communication failed • Power Line Communication (PLC) signal fault |
• EVSE • VCMS |
• Check and replace PLC communication module if the same fault code occurs after performing the charge by using the Electric Vehicle Charging Equipment (EVSE) that operates normally | |
| charger inlet | • Charging port overheat • Charging port temperature sensor fault |
• Wiring and connectors between the LDC output terminal and the high voltage junction box | • Inspect the charging port temperature sensor if the same fault code occurs after performing the charge by using the Electric Vehicle Charging Equipment (EVSE) that operates normally |
| • Inlet actuator fault • Inlet position sensor fault |
• Inlet actuator • Inlet position sensor |
• Check for lock/unlock via inlet actuator actuation test | |
| Fail-Safe | • Quick charge relay weld / performance abnormal | • Quick charge relay • Quick charge relay faulty wiring and connector connection |
• Check the quick charge relay in the high voltage junction box |
Vehicle Charge Management System (VCMS) Removal and Installation
Removal
|
| Check the EVSE, charger inlet assembly, quick charge relay and related controller before replacing the Vehicle Charging Management System (VCMS). |
- Perform the high voltage shut off procedure. (Refer to Battery Control System - “High Voltage Shut-off Procedure”)
- Remove the passenger luggage side trim (Driver Side). (Refer to Body - "Luggage Side Trim")
- Disconnect the Vehicle Charge Management System (VCMS) connector (A).
- Remove the VCMS bracket (A) after removing the nuts.
Tightening torque : 6.9 - 9,8 N·m
- Remove the VCMS (A) after removing the nuts.
Tightening torque : 9.8 - 11,8 N·m
Installation
|
- Install in the reverse order of removal.
- Install the Vehicle Charge Management System (VCMS) to the specified torque.
- If VCMS is dropped, it may cause internal damage. (Do not reuse)
- After replacing the VCMS and the related parts, vehicle should be checked that it charges normally.
Was this page helpful?