Transmission & Driveline

Calibration of Decel G Sensor

8steps
~48min
4/5difficulty
Done 0 of 8

Description

TCM stores calibration data (inherent characteristic value) of decel G sensor to provide accurate control.

Decel G sensor calibration must be performed when the following operation is performed. For work procedure, refer to Work Procedure.

  • Removing/Installing yaw rate/side/decel G sensor

  • Replacing yaw rate/side/decel G sensor

  • Replacing A/T assembly

  • Replacing control valve & TCM

  • Removing/Installing ABS actuator and electric unit (control unit)

  • Replacing ABS actuator and electric unit (control unit)

Work Procedure

PREPARATION BEFORE CALIBRATION PROCEDURE

  1. Park the vehicle on a flat road.

  2. Adjust pressure in all tires to the specified value. Refer to TIRE AIR PRESSURE : Service Data.

>>

GO TO 2.

PERFORM CALIBRATION

With CONSULT

  1. Ignition switch ON.

  2. Select “G sensor calibration” in “Work supports” in “TRANSMISSION”.

  3. Touch “START”.

Is “completed” displayed?

YES>>

GO TO 3.

NO>>

Perform the calibration again.

CHECK DTC

With CONSULT

  1. Ignition switch OFF and wait 10 seconds or more.

  2. Ignition switch ON.

  3. Select “Self Diagnostic Results” in “ABS”.

Is “C1145” or “C1146” detected?

YES>>

Refer to DTC Index.

NO>>

WORK END