Calibration of Decel G Sensor
Description
TCM stores calibration data (inherent characteristic value) of decel G sensor to provide accurate control.
Decel G sensor calibration must be performed when the following operation is performed. For work procedure, refer to Work Procedure.
Removing/Installing yaw rate/side/decel G sensor
Replacing yaw rate/side/decel G sensor
Replacing A/T assembly
Replacing control valve & TCM
Removing/Installing ABS actuator and electric unit (control unit)
Replacing ABS actuator and electric unit (control unit)
Work Procedure
PREPARATION BEFORE CALIBRATION PROCEDURE
Park the vehicle on a flat road.
Adjust pressure in all tires to the specified value. Refer to TIRE AIR PRESSURE : Service Data.
GO TO 2.
PERFORM CALIBRATION
With CONSULT
Ignition switch ON.
Select “G sensor calibration” in “Work supports” in “TRANSMISSION”.
Touch “START”.
Is “completed” displayed?
YES>>GO TO 3.
NO>>Perform the calibration again.
CHECK DTC
With CONSULT
Ignition switch OFF and wait 10 seconds or more.
Ignition switch ON.
Select “Self Diagnostic Results” in “ABS”.
Is “C1145” or “C1146” detected?
YES>>Refer to DTC Index.
NO>>WORK END