Freeze Frame Data
FREEZE FRAME DATA
FREEZE FRAME DATA
HINT:
- When a DTC is recorded, the freeze frame data records the current vehicle (sensor) status.
- Freeze frame data cannot be erased or updated until the recorded DTCs are cleared.
Tester display | Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
Elapsed Time after Freeze Trigger |
Time elapsed since freeze frame trigger |
Min.: 0 ms, Max.: 510 ms |
- |
- |
Number of IG ON |
Number of times the ignition switch has been turned to ON after freeze frame data was recorded |
0 à 31 |
- |
- |
Buzzer |
Instrument cluster buzzer |
ON or OFF |
OFF: Buzzer off |
No change |
Stop Light SW |
Stop light switch |
ON or OFF |
ON: Brake pedal depressed OFF: Brake pedal released |
- |
Parking Brake SW |
Parking Brake Switch |
ON or OFF |
ON: Parking brake applied OFF: Parking brake released |
- |
Gear Position |
Engaged gear information |
P/N, R, 1st-8th, Fail or Not R |
Actual engaged gear |
- |
Shift Lever Position |
Shift lever position information |
P/N, R, D/M, 1st-6th/B or Fail |
Actual shift lever position |
- |
Operated System |
Activated system status |
None, ABS, VSC, TRAC, BA, HAB, Fail, PBA, PB, HA-CTRL, TSC, MCB, Sys |
Actual operated system |
None: No operation is activated. ABS: ABS activated. VSC: VSC activated. TRAC: TRAC activated. BA: BA activated. HAB: HAB activated.* Fail: Fail-safe mode activated. PBA: PBA activated. PB: PB activated.* HA-CTRL: Hill-start assist control activated. TSC: Trailer sway control is activated* MCB: SCB activated.* Sys: System suppression activated. |
Master Cylinder Sensor |
Master cylinder pressure sensor value |
Min.: 0.00 V, Max.: 5.00 V |
Brake pedal released: 0.20 to 0.40 V |
The value increases when the brake pedal is depressed |
M/C Sensor Grade |
Master cylinder pressure sensor change |
Min.: -30 MPa/s, Max.: 225 MPa/s |
Brake pedal released or pedal held at a constant position: 0 MPa/s |
When the brake pedal is operated: Changes in proportion to the speed of pedal movement |
Yaw Rate Sensor |
Yaw rate sensor |
Min.: -128°/s, Max.: 127°/s |
Vehicle stopped: 0°/s Turning right: -128 to 0°/s Turning left: 0 to 127°/s |
- |
Lateral G |
Lateral G |
Min.: -25.10 m/s2, Max.: 24.90 m/s2 |
- |
While turning: Changes in proportion to lateral acceleration |
Forward and Rearward G |
Forward and Rearward G |
Min.: -25.10 m/s2, Max.: 24.90 m/s2 |
- |
During acceleration/deceleration: Changes in proportion to acceleration |
FR Wheel Speed |
Front right wheel speed sensor value |
Min.: 0 km/h, Max.: 326 km/h |
Vehicle stopped: 0 km/h |
When vehicle is driving at constant speed: No large fluctuation |
FL Wheel Speed |
Front left wheel speed sensor value |
Min.: 0 km/h, Max.: 326 km/h |
Vehicle stopped: 0 km/h |
When vehicle is driving at constant speed: No large fluctuation |
RR Wheel Speed |
Rear right wheel speed sensor value |
Min.: 0 km/h, Max.: 326 km/h |
Vehicle stopped: 0 km/h |
When vehicle is driving at constant speed: No large fluctuation |
RL Wheel Speed |
Rear left wheel speed sensor value |
Min.: 0 km/h, Max.: 326 km/h |
Vehicle stopped: 0 km/h |
When vehicle is driving at constant speed: No large fluctuation |
Vehicle Speed |
Maximum value for wheel speed sensor |
Min.: 0 km/h, Max.: 326 km/h |
Vehicle stopped: 0 km/h |
When vehicle is driving at constant speed: No large fluctuation |
Vehicle Speed Grade |
Vehicle speed grade |
Min.: -25.10 m/s2, Max.: 24.90 m/s2 |
Vehicle stopped: 0 m/s2 |
While driving: Changes in proportion to vehicle acceleration/deceleration |
FR Wheel Direction |
Front Right Wheel Direction Signal |
Forward or Reverse |
Forward: Forward Reverse: Reverse |
- |
FL Wheel Direction |
Front Left Wheel Direction Signal |
Forward or Reverse |
Forward: Forward Reverse: Reverse |
- |
RR Wheel Direction |
Rear Right Wheel Direction Signal |
Forward or Reverse |
Forward: Forward Reverse: Reverse |
- |
RL Wheel Direction |
Rear Left Wheel Direction Signal |
Forward or Reverse |
Forward: Forward Reverse: Reverse |
- |
Real Engine Torque |
Real Engine Torque |
Min.: -1 24 N·m, Max.: 1 23 N·m |
- |
- |
Accelerator Opening Angle % |
Accelerator Pedal Opening Angle Percentage |
Min.: 0.0%, Max.: 127.5% |
Accelerator pedal released: 0% |
While accelerator pedal is operating: Changes in proportion to pedal movement |
Brake Pedal Load Sensing SW |
Brake Pedal Load Detection Switch |
ON or OFF |
ON: Brake pedal depressed OFF: Brake pedal released |
- |
Inspection Mode |
Inspection Mode |
Other or Inspect |
Other: Normal mode Inspect: Inspection mode |
- |
Steering Angle Sensor |
Steering angle sensor |
Min.: -3,276.8°, Max.: 3,276.7° |
Turning left: Increases Turning right: Decreases |
- |
TRAC/VSC Off Mode |
TRAC/VSC OFF Mode |
Normal, TRAC OFF, VSC Expert Mode, VSC OFF |
Normal: Normal mode TRAC OFF: TRAC OFF mode VSC OFF: VSC OFF mode |
- |
Vehicle Speed (Control Value) |
Vehicle speed (control value) |
Min.: 0 km/h Max.: 326 km/h |
- |
- |
ECU +B1 Voltage |
Skid control ECU (brake actuator assembly) +B1 voltage |
0,00 à 20,00 V |
11 à 14 V |
- |
RH Actuator Motor Input Voltage |
Right parking brake motor input voltage (right parking brake actuator assembly) |
0,00 à 20,00 V |
- |
- |
RH Actuator Motor +Terminal Voltage |
Voltage on right parking brake motor positive (+) terminal side (right parking brake actuator assembly) |
0,00 à 20,00 V |
- |
- |
RH Actuator Motor -Terminal Voltage |
Voltage on right parking brake motor negative (-) terminal side (right parking brake actuator assembly) |
0,00 à 20,00 V |
- |
- |
LH Actuator Motor Input Voltage |
Left parking brake motor input voltage (left parking brake actuator assembly) |
0,00 à 20,00 V |
- |
- |
LH Actuator Motor +Terminal Voltage |
Voltage on left parking brake motor positive (+) terminal side (left parking brake actuator assembly) |
0,00 à 20,00 V |
- |
- |
LH Actuator Motor -Terminal Voltage |
Voltage on left parking brake motor negative (-) terminal side (left parking brake actuator assembly) |
0,00 à 20,00 V |
- |
- |
EPB Switch |
Electric Parking Brake Switch Input (Electric Parking Brake Switch Assembly) |
OFF, Lock, Release or Unknown |
OFF: Lock switch and release switch are in OFF position Lock: Lock switch released: Release switch in ON position |
If not normal, the release side of the Electric Parking Brake Switch (Electric Parking Brake Switch Assembly) may malfunction. HINT: EPB stands for electric parking brake. |
Auto Mode Request |
Auto Mode Request Status |
OFF or ON |
- |
- |
Shift Position |
Shift lever position |
P, N, R, D or Unknown |
P: Shift lever in P position N: Shift lever in N position R: Shift lever in R position D: Shift lever in D or M position |
If not operating normally, the gear engaged signal system is likely malfunctioning. |
IG Switch |
IG power supply status |
OFF or ON |
OFF: IG power supply voltage is not supplied to skid control ECU (brake actuator assembly) ON: IG power supply voltage is supplied to skid control ECU (brake actuator assembly) |
- |
Brake Hold Ready |
Brake hold control enable status |
OFF or ON |
- |
- |
Brake Hold Control Mode |
Brake hold control mode |
OFF, ON, Release or EPB |
OFF: Brake hold control is not operating ON: Brake hold control is operating Release: Brake hold control is released EPB: Parking brake is applied during brake hold control |
HINT: EPB stands for electric parking brake. |
RH Actuator Current Status |
Right Parking Brake Actuator Assembly Current Status |
Invalid or Valid |
Valid |
- |
LH Actuator Current Status |
Left Parking Brake Actuator Assembly Current Status |
Invalid or Valid |
Valid |
- |
RH Actuator Nut Stroke |
Right Parking Brake Actuator Assembly Nut Stroke Value |
0.000 to 8.160 mm (0 to 0.321 in.) |
- |
- |
LH Actuator Nut Stroke |
Left Parking Brake Actuator Assembly Nut Stroke Value |
0.000 to 8.160 mm (0 to 0.321 in.) |
- |
- |
RH Actuator Motor Actual Current |
Right Parking Brake Motor Actual Current Value (Right Parking Brake Actuator Assembly) |
-5,0362 à 50,5000 A |
- |
- |
RH Actuator 0 load Current |
Right Parking Brake Motor Zero Load Calibration Current Value (Right Parking Brake Actuator Assembly) |
-5,0362 à 50,5000 A |
- |
- |
LH Actuator Motor Actual Current |
Left Parking Brake Motor Actual Current Value (Left Parking Brake Actuator Assembly) |
-5,0362 à 50,5000 A |
- |
- |
LH Actuator 0 load Current |
Left Parking Brake Motor Actual Current Value (Left Parking Brake Actuator Assembly) |
-5,0362 à 50,5000 A |
- |
- |
Counter of IG ON After EPB Control Cancel |
Number of times the ignition switch has been turned ON after EPB control cancellation |
0 to 255 times |
- |
- |
RH Actuator Status |
Right Parking Brake Actuator Assembly Status |
Default, Lock, Lock Dynamic, Release, Lock Faulty, Unexpected, Lock Standby, Release Standby, Lock Dynamic Standby, Release Dynamic Standby, Lock Dynamic Faulty, Lock Standard Control, Lock Dynamic Control, Lock Control for Prevention Loosen by High Temperature, Lock Control for Prevention Slipping Down, Re-Lock Control by Switch, Recovery Lock Control, Lock Control After Dynamic PKB, Release Standard Control, Release Dynamic Control, Full Release Control |
- |
- |
LH Actuator Status |
Left Parking Brake Actuator Assembly Status |
Default, Lock, Lock Dynamic, Release, Lock Faulty, Unexpected, Lock Standby, Release Standby, Lock Dynamic Standby, Release Dynamic Standby, Lock Dynamic Faulty, Lock Standard Control, Lock Dynamic Control, Lock Control for Prevention Loosen by High Temperature, Lock Control for Prevention Slipping Down, Re-Lock Control by Switch, Recovery Lock Control, Lock Control After Dynamic PKB, Release Standard Control, Release Dynamic Control, Full Release Control |
- |
- |
Detailed Freeze DTC |
Number of Freeze Frame Detailed DTCs |
0 à 65 535 |
- |
- |
RH Actuator Motor Gradient Current |
Right Parking Brake Motor Gradient Current (Right Parking Brake Actuator Assembly) |
-5,0362 à 50,5000 A |
- |
- |
LH Actuator Motor Gradient Current |
Left Parking Brake Motor Gradient Current (Left Parking Brake Actuator Assembly) |
-5,0362 à 50,5000 A |
- |
- |
RH Actuator Motor Relay1 |
Right Parking Brake Motor Relay 1 Status |
OFF or ON |
- |
- |
RH Actuator Motor Relay2 |
Right Parking Brake Motor Relay 2 Status |
OFF or ON |
- |
- |
RH Actuator Motor Relay3 |
Right Parking Brake Motor Relay 3 Status |
OFF or ON |
- |
- |
RH Actuator Motor Relay4 |
Right Parking Brake Motor Relay 4 Status |
OFF or ON |
- |
- |
LH Actuator Motor Relay1 |
Left Parking Brake Motor Relay 1 Status |
OFF or ON |
- |
- |
LH Actuator Motor Relay2 |
Left Parking Brake Motor Relay 2 Status |
OFF or ON |
- |
- |
LH Actuator Motor Relay3 |
Left Parking Brake Motor Relay 3 Status |
OFF or ON |
- |
- |
LH Actuator Motor Relay4 |
Left Parking Brake Motor Relay 4 Status |
OFF or ON |
- |
- |
RH Actuator Motor Current High |
Right Parking Brake Motor Overcurrent Status (Right Parking Brake Actuator Assembly) |
OFF or ON |
- |
- |
RH Actuator Motor Driver Operation Status |
Right Parking Brake Motor Driver Operation Status (Right Parking Brake Actuator Assembly) |
OK or NG |
- |
- |
LH Actuator Motor Current High |
Left Parking Brake Motor Overcurrent Status (Left Parking Brake Actuator Assembly) |
OFF or ON |
- |
- |
LH Actuator Motor Driver Operation Status |
Left Parking Brake Motor Driver Operation Status (Left Parking Brake Actuator Assembly) |
OK or NG |
- |
- |
- *: Not equipped
(a) Using the Techstream, the vehicle status (sensors) can be checked while the system is operating or when a DTC has been recorded.