Exterior Lighting

Inspection

~2min read

INSPECTION

PROCEDURE

1. INSPECT REAR LH HEIGHT CONTROL SENSOR SUB-ASSEMBLY

(a) Preparation for inspection

(1) Check the standard, high and low positions of the link that will be used in the following inspection.

  • The standard position is 58° from the maximum link angle (high), and 51° from the maximum link angle (low).
  • The high position (+33.85°) is 24.15° from the maximum link angle (high beam).
  • The low position (-33.85°) is 17.15° from the maximum link angle (low).

*a

Standard position

*b

Maximum link angle (low)

*c

Maximum link angle (high)

*d

51°

*e

58°

*f

-33,85°

*g

+33,85°

-

-

(2) Connect 3 dry cell batteries (1.5 V) in series.

NOTICE:

Do not use rechargeable batteries as they may not output a voltage of 1.5 V.

(3) Connect the positive (+) battery cable to terminal 3 (SHB) and the negative (-) cable to terminal 1 (SHG).

*a

Component without wire harness connected

(rear LH height control sensor sub-assembly)

*b

Low

*c

Standard position

*d

High

*e

-33,85°

*f

+33,85°

(4) Measure the voltage between terminal 2 (SHRR) and terminal 1 (SHG) while slowly moving the link up and down.

Standard voltage:

Tester Connection

Condition

Specified Condition

1 (SHG) - 2 (SHRR)

+33.85° (high beam)

4,15 V

1 (SHG) - 2 (SHRR)

0° (standard position)

2,5 V

1 (SHG) - 2 (SHRR)

-33.85° (low beam)

1,04 V

If the result is not as specified, replace the rear left height control sensor sub-assembly.