Heating,Ventilation And Air Conditioning
Refrigerant Recovery/Recycling/Charging/Vacuum/Leak Test
In this manual: Heating,Ventilation And Air Conditioning
26steps
~156min
4/5difficulty
Done 0 of 26
Refrigerant Recovery/Recycling/Charging/Vacuum/Leak Test (R-134a)
Install the refrigerant recovery/recycling/charging equipment- Connect the refrigerant recovery/recycling/charging equipment to the high-pressure service port (A) and low-pressure service port (B).
Refrigerant charging equipment should be installed on a flat surface so that it is easy to recover the refrigerant and in particular, the refrigerant can be accurately injected. - Perform the refrigerant recovery using the refrigerant recovery/recycling/charging equipment while the high and low-pressure valves open.
Never disconnect the air conditioning system until the refrigerant has been completely recovered. If it is separated before the recovery of the refrigerant is completed, be careful as the refrigerant and oil are discharged into the vehicle by the pressure in the air conditioning system and contaminate it. - If the refrigerant is recovered too quickly, it causes the compressor oil to drain from the system.
- Refrigerant recovery must be performed with the high and low pressure valves opened. If only one valve is opened, the refrigerant recovery time increases.
- Measure the amount of compressor oil drained from the air conditioning system after the recovery operation is completed. Supplement the compressor oil drained when charging the air conditioner refrigerant.
| When charging the refrigerant, the air conditioning system must be evacuated. This vacuum operation is performed to remove all the air and moisture that have flowed into the unit, and the system is performed the evacuating operation for more than 10 minutes after each part is installed. |
- Perform the air conditioning system vacuum using the refrigerant recovery/recycling/charging equipment while the high and low-pressure valves open.
- If the gauge is maintained in the vacuum zone for 10 minutes while the high and low pressure valves are opened, the vacuum has been performed normally. If the pressure increases, there is a leak in the system, so repair the leak by the following order.
- Charging the system with refrigerant charging equipment. (Refer to Refrigerant charge)
- Check the refrigerant leak with leak detector and repair if leak is found. (Refer to Refrigerant leak test)
- Drain the refrigerant again and evacuate the system.
- After evacuating for more than 10 minutes, check the vacuum and close both high and low pressure valves. This state is ready for charging.
Compressor oil must be applied to the O-ring when assembling air conditioner parts, and cleanliness must be maintained to prevent foreign substances from entering, especially gloves. - Replenish the capacity of discharged compressor oil by using refrigerant recovery/recycling/charging equipment while the high pressure valve is opened after vacuum the air conditioning system.
If the oil is not added when charging the refrigerant, the lubricity deteriorates due to insufficient oil in the system, which causes problem such as compressor sticking. - Charge the refrigerant with specified capacity by using the refrigerant recovery/recycling/charging equipment while opening the high-pressure valve and then closing the high pressure valve.
Regulated refrigerant amount Heat pump : 900 ± 25 g (31.75 ± 0.88 oz.) Non heat pump : 800 ± 25 g (28.22 ± 0.88 oz.)
Do not overcharge the refrigerant as there is a risk of damage to the compressor. - Check if the refrigerant is not leaking from the system with leak detector. (Refer to refrigerant leak test)
- Check the torque of the connection part, and if it is too loose, check the gas leak with leak detector after tightening it with the tightening torque.
- If leakage continues even after re-tightening the connection part, drain the refrigerant and separate the connection part to check the contact surface for damage. If there is even a small damage, replace it with a new one.
- Check the compressor oil and add oil if necessary.
- Charging the system and check for gas leakage. If there is no problem, evacuate the system before charging.
Refrigerant Recovery/Recycling/Charging/Vacuum/Leak Test (R-1234yf)
Install the refrigerant recovery/recycling/charging equipment- Connect the refrigerant recovery/recycling/charging equipment to the high-pressure service port (A) and low-pressure service port (B).
Refrigerant charging equipment should be installed on a flat surface so that it is easy to recover the refrigerant and in particular, the refrigerant can be accurately injected. - Perform the refrigerant recovery using the refrigerant recovery/recycling/charging equipment while the high and low-pressure valves open.
Never disconnect the air conditioning system until the refrigerant has been completely recovered. If it is separated before the recovery of the refrigerant is completed, be careful as the refrigerant and oil are discharged into the vehicle by the pressure in the air conditioning system and contaminate it. - If the refrigerant is recovered too quickly, it causes the compressor oil to drain from the system.
- Refrigerant recovery must be performed with the high and low pressure valves opened. If only one valve is opened, the refrigerant recovery time increases.
- Measure the amount of compressor oil drained from the air conditioning system after the recovery operation is completed. Supplement the compressor oil drained when charging the air conditioner refrigerant.
| When charging the refrigerant, the air conditioning system must be evacuated. This vacuum operation is performed to remove all the air and moisture that have flowed into the unit, and the system is performed the evacuating operation for more than 10 minutes after each part is installed. |
- Perform the air conditioning system vacuum using the refrigerant recovery/recycling/charging equipment while the high and low-pressure valves open.
- If the gauge is maintained in the vacuum zone for 10 minutes while the high and low pressure valves are opened, the vacuum has been performed normally. If the pressure increases, there is a leak in the system, so repair the leak by the following order.
- Charging the system with refrigerant charging equipment. (Refer to Refrigerant charge)
- Check the refrigerant leak with leak detector and repair if leak is found. (Refer to Refrigerant leak test)
- Drain the refrigerant again and evacuate the system.
- After evacuating for more than 10 minutes, check the vacuum and close both high and low pressure valves. This state is ready for charging.
Compressor oil must be applied to the O-ring when assembling air conditioner parts, and cleanliness must be maintained to prevent foreign substances from entering, especially gloves. - Replenish the capacity of discharged compressor oil by using refrigerant recovery/recycling/charging equipment while the high pressure valve is opened after vacuum the air conditioning system.
If the oil is not added when charging the refrigerant, the lubricity deteriorates due to insufficient oil in the system, which causes problem such as compressor sticking. - Charge the refrigerant with specified capacity by using the refrigerant recovery/recycling/charging equipment while opening the high-pressure valve and then closing the high pressure valve.
Regulated refrigerant amount Heat pump : 850 ± 25 g (29.98 ± 0.88 oz.) Non heat pump : 750 ± 25 g (17.88 ± 0.88 oz.)
Do not overcharge the refrigerant as there is a risk of damage to the compressor. - Check if the refrigerant is not leaking from the system with leak detector. (Refer to refrigerant leak test)
- Check the torque of the connection part, and if it is too loose, check the gas leak with leak detector after tightening it with the tightening torque.
- If leakage continues even after re-tightening the connection part, drain the refrigerant and separate the connection part to check the contact surface for damage. If there is even a small damage, replace it with a new one.
- Check the compressor oil and add oil if necessary.
- Charging the system and check for gas leakage. If there is no problem, evacuate the system before charging.