DESCRIPTION

The main body ECU (multiplex network body ECU) controls the ambient lights.

WIRING DIAGRAM

PRECAUTION / NOTICE / HINT

NOTICE:

  • Check the fuses for the circuits related to this system before performing the following procedure.
  • Before replacing the Main Body ECU (Multiplex Network Body ECU), refer to the registration section.*1

    Click here

    • *1: with Smart Key System

PROCEDURE

  1. PERFORM ACTIVE TEST USING TECHSTREAM

(a) Connect the Techstream to the DLC3.

(b) Turn the ignition switch to ON.

(c) Turn on the Techstream.

(d) Select the following menu items: Body Electrical / Main Body / Active Test.

(e) Perform the Active Test by following the Techstream instructions.

Body Electrical > Main Body > Active Test

Tester display

Item

Control Range

Diagnostic Note

Interior Illumination Light1

  • Cup holder light
  • Door ambient light

ON or OFF

Preconditions for using the Active Test to control the light controlled by the high beam/low beam switch:

  • Ignition switch in the ON position.
  • The shift lever is in a position other than P.

Interior Illumination Light2

  • Cup holder light
  • Door ambient light

ON or OFF

Preconditions for using the Active Test to control the light controlled by the high beam/low beam switch:

  • Ignition switch in the ON position.
  • The shift lever is in a position other than P.
Body Electrical > Main Body > Active Test

Interior Illumination Light1

Body Electrical > Main Body > Active Test

Interior Illumination Light2

OK:

The ambient light illuminates.

Result:

Result

Proceed to

OK

A

NG (no ambient light illuminates)

B

NG (cup holder light does not illuminate)

C

NG (door ambient light does not illuminate)

D

A

GO TO APPLICABLE SYSTEM AS INDICATED IN THE PROBLEM SYMPTOMS TABLE

C

GO TO STEP 4

D

GO TO STEP 7

B
  1. CHECK WIRE HARNESS AND CONNECTOR (POWER SOURCE - INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY)

(a) Disconnect the connector from the instrument panel junction block assembly.

(b) Measure the voltage according to the value(s) in the table below.

Standard voltage:

Tester Connection

Condition

Specified Condition

3K-1 - Body Ground

Always

11 à 14 V

*a

Front view of wire harness side connector

(to Instrument Panel Junction Block Assembly)

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

OK
  1. INSPECT INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY

(a) Disconnect connector 3D from the instrument panel junction block assembly.

(b) Measure the resistance according to the value(s) in the table below.

*a

Component without wire harness connected

(instrument panel junction block assembly)

-

-

Standard resistance:

Tester Connection

Condition

Specified Condition

3K-1 - 3D-24

Always

Below 1 Ω

3K-1 - 3D-25

Always

Below 1 Ω

3K-1 - 3D-26

Always

Below 1 Ω

3K-1 - 3D-27

Always

Below 1 Ω

OK

GO TO APPLICABLE SYSTEM AS INDICATED IN THE PROBLEM SYMPTOMS TABLE

NG

REPLACE INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY

  1. INSPECT INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY

(a) Disconnect connector 3D from the instrument panel junction block assembly.

(b) Disconnect connector 3K from the instrument panel junction block assembly.

(c) Measure the resistance according to the value(s) in the table below.

*a

Component without wire harness connected

(instrument panel junction block assembly)

-

-

Standard resistance:

Tester Connection

Condition

Specified Condition

3K-1 - 3D-26

Always

Below 1 Ω

3K-1 - 3D-27

Always

Below 1 Ω

NG

REPLACE INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY

OK
  1. CHECK WIRE HARNESS AND CONNECTOR (INSTRUMENT CLUSTER FINISH PANEL GARNISH - INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY)

(a) Disconnect connector F87 from the instrument cluster finish panel garnish.

(b) Disconnect connector F88 from the center instrument cluster finish panel garnish.

(c) Measure the resistance according to the value(s) in the table below.

Standard resistance:

Tester Connection

Condition

Specified Condition

F87-2 (B) - 3D-26

Always

Below 1 Ω

F88-2 (B) - 3D-27

Always

Below 1 Ω

F87-2 (B) or 3D-26 - Body ground

Always

10 kΩ minimum

F88-2 (B) or 3D-27 - Body ground

Always

10 kΩ minimum

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

OK
  1. CHECK WIRE HARNESS AND CONNECTOR (INSTRUMENT CLUSTER FINISH PANEL GARNISH - MAIN BODY ECU (MULTIPLEX NETWORK BODY ECU))

(a) Disconnect connector F16 from the main body ECU (multiplex network body ECU).

(b) Measure the resistance according to the value(s) in the table below.

Standard resistance:

Tester Connection

Condition

Specified Condition

F87-1 (E) - F16-21 (LED1)

Always

Below 1 Ω

F88-1 (E) - F16-21 (LED1)

Always

Below 1 Ω

F87-1 (E) or F16-21 (LED1) - Body ground

Always

10 kΩ minimum

F88-1 (E) or F16-21 (LED1) - Body ground

Always

10 kΩ minimum

OK

REPLACE MAIN BODY ECU (MULTIPLEX NETWORK BODY ECU)

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

  1. INSPECT INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY

(a) Disconnect the connectors from the instrument panel junction block assembly.

(b) Measure the resistance according to the value(s) in the table below.

*a

Component without wire harness connected

(instrument panel junction block assembly)

-

-

Standard resistance:

Tester Connection

Condition

Specified Condition

3K-1 - 3D-24

Always

Below 1 Ω

3K-1 - 3D-25

Always

Below 1 Ω

NG

REPLACE INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY

OK
  1. CHECK WIRE HARNESS AND CONNECTOR (NO. 1 INTERIOR LIGHT ASSEMBLY - INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY)

(a) Disconnect connector I11 from the No. 1 right interior light assembly.

(b) Disconnect connector J9 from the No. 1 left interior light assembly.

(c) Measure the resistance according to the value(s) in the table below.

Standard resistance:

Tester Connection

Condition

Specified Condition

I11-1 (+) - 3D-24

Always

Below 1 Ω

I11-1 (+) or 3D-24 - Body ground

Always

10 kΩ minimum

J9-1 (+) - 3D-25

Always

Below 1 Ω

J9-1 (+) or 3D-25 - Body ground

Always

10 kΩ minimum

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

OK
  1. CHECK WIRE HARNESS AND CONNECTOR (NO. 1 INTERIOR LIGHT ASSEMBLY - MAIN BODY ECU (MULTIPLEX NETWORK BODY ECU))

(a) Disconnect connector F16 from the main body ECU (multiplex network body ECU).

(b) Measure the resistance according to the value(s) in the table below.

Standard resistance:

Tester Connection

Condition

Specified Condition

I11-2 (-) - F16-22 (LED2)

Always

Below 1 Ω

I11-2 (-) or F16-22 (LED2) - Body ground

Always

10 kΩ minimum

J9-2 (-) - F16-22 (LED2)

Always

Below 1 Ω

J9-2 (-) or F16-22 (LED2) - Body ground

Always

10 kΩ minimum

OK

REPLACE MAIN BODY ECU (MULTIPLEX NETWORK BODY ECU)

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR