Interior Light

Interior Light Auto Cut Circuit

~3min read

DESCRIPTION

The Main Body ECU (Multiplex Network Body ECU) controls the operation of the DOME CUT relay to supply power to the interior lights. When the battery saver function operates while the interior lights are ON, the Main Body ECU (Multiplex Network Body ECU) activates the DOME CUT relay to turn the lights off.

WIRING DIAGRAM

PRECAUTION / NOTICE / HINT

NOTICE:

  • Check the fuses for the circuits related to this system before performing the following procedure.
  • Before replacing the main body ECU (multiplex network body ECU), refer to the registration section*1.

    Click here

    • *1: with Smart Key System

PROCEDURE

  1. PERFORM ACTIVE TEST USING TECHSTREAM

(a) Connect the Techstream to the DLC3.

(b) Turn the ignition switch to ON.

(c) Turn on the Techstream.

(d) Select the following menu items: Body Electrical / Main Body / Active Test.

(e) Perform the Active Test by following the Techstream instructions.

Body Electrical > Main Body > Active Test

Tester display

Item

Control Range

Diagnostic Note

Relay for Interior Light Auto Cut Function

DOME CUT Relay

ON or OFF

When performing the Active Test, turn on all interior lights.

  • ON: DOME CUT relay OFF (interior lights OFF)
  • OFF: DOME CUT relay ON (interior lights ON)
Body Electrical > Main Body > Active Test

Relay for Interior Light Auto Cut Function

OK:

All interior lights turn off when the ON position is selected.

OK

GO TO APPLICABLE SYSTEM AS INDICATED IN THE PROBLEM SYMPTOMS TABLE

NG
  1. CHECK WIRE HARNESS AND CONNECTOR (POWER SOURCE - INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY)

(a) Disconnect connector 3K from the instrument panel junction block assembly.

(b) Measure the voltage according to the value(s) in the table below.

Standard voltage:

Tester Connection

Condition

Specified Condition

3K-1 - Body Ground

Always

11 à 14 V

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

OK
  1. INSPECT INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY

(a) Remove the instrument panel junction block assembly.

Click here

(b) Remove the main body ECU (multiplex network body ECU) from the instrument panel junction block assembly.

Click here

(c) Measure the voltage and resistance according to the value(s) in the table below.

*a

Component without wire harness connected

(instrument panel junction block assembly)

-

-

Standard voltage:

Tester Connection

Condition

Specified Condition

3H-19 - Battery negative terminal

Battery positive (+) → 3K-1

Battery negative (-) terminal → MB-23 (DOMR)

11 à 14 V

3D-9 - Battery negative terminal

Battery positive (+) → 3K-1

Battery negative (-) terminal → MB-23 (DOMR)

11 à 14 V

Standard resistance:

Tester Connection

Condition

Specified Condition

3K-1 - 3H-19

Always

10 kΩ minimum

3K-1 - 3D-9

Always

10 kΩ minimum

OK

REPLACE MAIN BODY ECU (MULTIPLEX NETWORK BODY ECU)

NG

REPLACE INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY