Interior Light

IG Signal Circuit

~4min read

DESCRIPTION

This circuit detects whether the ignition switch is ON or OFF, and transmits this information to the main body ECU (multiplex network body ECU).

WIRING DIAGRAM

PRECAUTION / NOTICE / HINT

NOTICE:

  • Check the fuses for the circuits related to this system before performing the following procedure.
  • Before replacing the main body ECU (multiplex network body ECU), refer to the registration section*1.

    Click here

    • *1: with Smart Key System

PROCEDURE

  1. CHECK DTC (SMART KEY SYSTEM (for Start Function))

HINT:

If the vehicle is not equipped with a smart key system, go to the next step (A).

(a) Clear the DTCs.

Click here

Body Electrical > Power Source Control > Clear DTCs

(b) Check DTCs.

Click here

Body Electrical > Power Source Control > Trouble Codes

Result:

Result

Proceed to

No DTCs related to the smart key system (for start function) are output.

A

DTCs for the smart key system (for start function) are output.

B

B

GO TO SMART KEY SYSTEM (for start function)

A
  1. CHECK VALUE USING TECHSTREAM

(a) Connect the Techstream to the DLC3.

(b) Turn the ignition switch to ON.

(c) Turn on the Techstream.

(d) Select the following menus: Body Electrical / Main Body / Data List.

(e) Read the Data List by following the instructions on the Techstream.

Body Electrical > Main Body > Data List

Tester display

Item

Range

Normal Condition

Diagnostic Note

IG SW

Ignition Switch ON Position Signal

ON or OFF

ON: Ignition switch ON

OFF: Ignition switch in OFF position

-

Body Electrical > Main Body > Data List

IG SW

OK:

The normal conditions listed above are displayed.

Result:

Result

Proceed to

OK

A

NG

B

A

GO TO APPLICABLE SYSTEM AS INDICATED IN THE PROBLEM SYMPTOMS TABLE

B
  1. CHECK HARNESS AND CONNECTOR (BATTERY POWER SOURCE - INSTRUMENT PANEL JUNCTION BLOCK ASSY)

(a) Disconnect connector 3K from the instrument panel junction block assembly.

(b) Measure the voltage according to the value(s) in the table below.

Standard voltage:

Tester Connection

Condition

Specified Condition

3K-1 - Body Ground

Always

11 à 14 V

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

OK
  1. CHECK HARNESS AND CONNECTOR (INSTRUMENT PANEL JUNCTION BLOCK ASSY - INSTRUMENT PANEL JUNCTION BLOCK ASSY)

(a) Remove the instrument panel junction block assembly.

Click here

(b) Measure the voltage according to the value(s) in the table below.

Standard resistance:

Tester Connection

Ignition switch position

Specified Condition

3D-30 - 3A-15

Ignition Switch in OFF position

Below 1 Ω

3D-30 or 3A-15 - Body ground

Ignition Switch in OFF position

10 kΩ minimum

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

OK
  1. INSPECT INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY

(a) Remove the instrument panel junction block assembly.

Click here

(b) Remove the main body ECU (multiplex network body ECU) from the instrument panel junction block assembly.

Click here

(c) Measure the resistance according to the value(s) in the table below.

*a

Component without wire harness connected

(instrument panel junction block assembly)

-

-

Standard resistance:

Tester Connection

Condition

Specified Condition

3K-1 - 3D-30

Battery disconnected from 3A-17 and 3D-3

10 kΩ minimum

3K-1 - 3D-30

Battery positive (+) → 3A-17

Battery negative (-) → 3D-3

Below 1 Ω

3A-15 - MB-32 (IG)

Always

Below 1 Ω

OK

REPLACE MAIN BODY ECU (MULTIPLEX NETWORK BODY ECU)

NG