Fuel system
Solenoid Valve Inspection (SCSV)
In this manual: Fuel system
~1min read
PROCEDURE
1. Using jumper wires, apply battery voltage to the solenoid valve connector terminals.

2. Make sure the valve operates with a distinct click.

3. Using an ohmmeter, check that there is no continuity between the connector terminals and the solenoid valve body.

4. Using an ohmmeter, measure the resistance between the solenoid valve connector terminals.
Resistance: 48-60 kΩ at 20 °C