Cooling fan
Diagnosis Procedure
1.CHECK GROUND CONNECTION 1. Turn ignition switch OFF.2. Check ground connection E38. Refer to Ground Inspection in GI-44, "Circuit Inspection".
Is the inspection result normal? YES >> GO TO 2.
NO >> Repair or replace ground connection.
2.CHECK COOLING FAN MOTOR CIRCUIT 1. Disconnect cooling fan motor harness connector.2. Check the continuity between IPDM E/R harness connector and cooling fan motor harness connector.

3. Check the continuity between cooling fan motor harness connector and ground.

4. Also check harness for short to ground and short to power.
YES or NO YES >> GO TO 4.
NO >> GO TO 3.
3.DETECT MALFUNCTIONING PARTCheck the following.
• Harness for open or short between cooling fan motor and IPDM E/R • Harness for open or short between cooling fan motor and ground
>> Repair open circuit or short to ground or short to power in harness or connectors.
4.CHECK COOLING FAN MOTORRefer to EC-1015, "Component Inspection".
YES or NO YES >> GO TO 5.
NO >> Replace cooling fan motor.
5.CHECK INTERMITTENT INCIDENTPerform GI-42, "Intermittent Incident".
YES or NO YES >> Replace IPDM E/R. Refer to PCS-34, "Exploded View" (WITH I-KEY) or PCS-63, "Exploded View" (WITHOUT I-KEY).
NO >> Repair or replace harness or connector.
Component Inspection
1.CHECK COOLING FAN MOTOR 1. Turn ignition switch OFF. 2. Disconnect cooling fan motor harness connector E75 and E76.3. Supply cooling fan motor terminals with battery voltage and check operation.

Is the inspection result normal? YES >> INSPECTION END
NO >> Replace cooling fan motor.