P047B exhaust gas pressure sensor 2
DTC Logic
DTC DETECTION LOGIC

Diagnosis Proce
1.CHECK GROUND CONNECTIONS 1. Turn ignition switch OFF and wait at least 20 seconds.2. Check ground connection E38. Refer to Ground inspection in GI-44, "Circuit Inspection".
Is the inspection result normal? YES >> GO TO 2.
NO >> Repair or replace ground connection.
2.CHECK EXHAUST GAS PRESSURE SENSOR 2 POWER SUPPLY CIRCUIT 1. Disconnect exhaust gas pressure sensor 2 harness connector. 2. Turn ignition switch ON.3. Check the voltage between exhaust pressure sensor 2 harness connector and ground.

Is the inspection result normal? YES >> GO TO 3.
NO >> Repair open circuit or short to ground or short to power in harness or connectors.
3.CHECK EXHAUST GAS PRESSURE SENSOR 2 GROUND CIRCUIT FOR OPEN AND SHORT 1. Turn ignition switch OFF and wait at least 20 seconds.2. Check the continuity between exhaust gas pressure sensor 2 harness connector and ECM harness connector.

3. Also check harness for short to ground and short to power.
Is the inspection result normal? YES >> GO TO 4.
NO >> Repair open circuit or short to ground or short to power in harness or connectors.
4.CHECK EXHAUST GAS PRESSURE SENSOR 2 INPUT SIGNAL CIRCUIT FOR OPEN AND SHORT1. Check the continuity between exhaust gas pressure sensor 2 harness connector and ECM harness connector.

2. Also check harness for short to ground and short to power.
Is the inspection result normal? YES >> GO TO 5.
NO >> Repair open circuit or short to ground or short to power in harness or connectors.
5.CHECK INTERMITTENT INCIDENTRefer to GI-42, "Intermittent Incident".
Is the inspection result normal? YES >> Replace exhaust gas pressure sensor 2.
NO >> Repair or replace.