Power supply and ground circuit
Start engine.
Is engine running? YES >> GO TO 6.
NO >> GO TO 2.
2.CHECK GROUND CONNECTION-I 1. Turn ignition switch OFF.2. Check ground connection E38. Refer to Ground Inspection in GI-44, "Circuit Inspection".
Is the inspection result normal? YES >> GO TO 3.
NO >> Repair or replace ground connection.
3.CHECK ECM POWER SUPPLY CIRCUIT-I 1. Turn ignition switch ON.2. Check the voltage between ECM harness connector and ground.

Is the inspection result normal? YES >> GO TO 5.
NO >> GO TO 4.
4.DETECT MALFUNCTIONING PARTCheck the following.
• Harness connectors M77, E105 • 10A fuse (No. 2)
• Harness for open or short between ECM and fuse
>> Repair open circuit or short to ground or short to power in harness or connectors.
5.CHECK ECM GROUND CIRCUIT FOR OPEN AND SHORT-I 1. Disconnect ECM harness connectors.2. Check the continuity between ECM harness connector and ground.

3. Also check harness for short to power.
Is the inspection result normal? YES >> GO TO 6.
NO >> Repair open circuit or short to power in harness or connectors.
6.CHECK ECM POWER SUPPLY CIRCUIT-II 1. Turn ignition switch OFF and wait at least 10 seconds.2. Check the voltage between ECM harness connector and ground.

Is the inspection result normal? YES >> GO TO 13.
NO-1 >> Battery voltage does not exist: GO TO 7.
NO-2 >> Battery voltage exists for more than a few seconds: GO TO 10.
7.CHECK ECM POWER SUPPLY CIRCUIT-III 1. Turn ignition switch OFF and wait at least 10 seconds.2. Check the voltage between ECM harness connector and ground.

Is the inspection result normal? YES >> GO TO 8.
NO >> GO TO 10.
8.CHECK ECM POWER SUPPLY CIRCUIT-IV 1. Disconnect ECM harness connector. 2. Disconnect IPDM E/R harness connector.3. Check the continuity between ECM harness connector and IPDM E/R harness connector.

4. Also check harness for short to ground and short to power.
Is the inspection result normal? YES >> GO TO 15.
NO >> GO TO 9.
9.DETECT MALFUNCTIONING PARTCheck the following.
• Harness or connectors E8, F1 • Harness for open or short between ECM and IPDM E/R
>> Repair open circuit or short to ground or short to power in harness or connectors.
10.CHECK ECM POWER SUPPLY CIRCUIT-V 1. Disconnect ECM harness connector. 2. Disconnect IPDM E/R harness connector.3. Check the continuity between ECM harness connector and IPDM E/R harness connector.

4. Also check harness for short to ground and short to power.
Is the inspection result normal? YES >> GO TO 12.
NO >> GO TO 11.
11.DETECT MALFUNCTIONING PARTCheck the following.
• Harness or connectors E8, F1 • Harness for open or short between ECM and IPDM E/R
>> Repair open circuit or short to ground or short to power in harness or connectors.
12.CHECK 20A FUSE 1. Disconnect 20A fuse (No. 43) from IPDM E/R.2. Check 20A fuse.
Is the inspection result normal? YES >> GO TO 15.
NO >> Replace 20A fuse.
13.CHECK GROUND CONNECTION-II 1. Turn ignition switch OFF.2. Check ground connection E38. Refer to Ground Inspection in GI-44, "Circuit Inspection".
Is the inspection result normal? YES >> GO TO 14.
NO >> Repair or replace ground connection.
14.CHECK ECM GROUND CIRCUIT FOR OPEN AND SHORT-II 1. Disconnect ECM harness connector.2. Check the continuity between ECM harness connector and ground.

3. Also check harness for short to power.
Is the inspection result normal? YES >> GO TO 15.
NO >> Repair open circuit or short power in harness or connectors.
15.CHECK INTERMITTENT INCIDENTRefer to GI-42, "Intermittent Incident", ???INCIDENT SIMULATION TESTS??? and ???GROUND INSPECTION???.
Is the inspection result normal? YES >> Replace IPDM E/R.
NO >> Repair open circuit or short to power in harness or connectors.