P0409 EGR volume control valve control position sensor
DTC Logic
DTC DETECTION LOGIC

Diagnosis Procedure
1.CHECK GROUND CONNECTIONS 1. Turn ignition switch OFF.2. Check ground connection E38. Refer to Ground inspection in GI-44, "Circuit Inspection".
Is the inspection result normal? YES >> GO TO 2.
NO >> Repair or replace ground connection.
2.CHECK EGR VOLUME CONTROL VALVE CONTROL POSITION SENSOR POWER SUPPLY CIRCUIT 1. Disconnect EGR volume control valve harness connector. 2. Turn ignition switch ON.3. Check the voltage between EGR volume control valve control position sensor connector and ground.

Is the inspection result normal? YES >> GO TO 3.
NO >> Repair open circuit or short to ground or short to power in harness or connectors.
3.CHECK EGR VOLUME CONTROL VALVE CONTROL POSITION SENSOR GROUND CIRCUIT FOR OPEN AND SHORT 1. Turn ignition switch OFF. 2. Disconnect ECM harness connector.3. Check the continuity between EGR volume control valve control position sensor harness connector and ECM harness connector.

4. Also check harness for short to ground and short to power.
Is the inspection result normal? YES >> GO TO 4.
NO >> Repair open circuit or short to ground or short to power in harness or connectors.
4.CHECK EGR VOLUME CONTROL VALVE CONTROL POSITION SENSOR INPUT CIRCUIT FOR OPEN AND SHORT1. Check the continuity between EGR volume control valve control position sensor harness connector and ECM harness connector.

2. Also check harness for short to ground and short to power.
Is the inspection result normal? YES >> GO TO 5.
NO >> Repair open circuit or short to ground or short to power in harness or connectors.
5.CHECK INTERMITTENT INCIDENTRefer to GI-42, "Intermittent Incident", ???INCIDENT SIMULATION TESTS??? and ???GROUND INSPECTION???.
Is the inspection result normal? YES >> GO TO 6.
NO >> Repair or replace.
6.REPLACE EGR VOLUME CONTROL VALVE 1. Replace the EGR volume control valve.2. Perform EC-881, "Work Procedure"
>> INSPECTIO END