Engine Control System/Fuel System
Repair Procedures - CVVT Oil Control Valve (OCV)
In this manual: Engine Control System/Fuel System
7steps
~42min
2/5difficulty
Done 0 of 7
Inspection
- Turn the ignition off.
- Disconnect the OCV connector.
- Measure the resistance between terminals 1 and 2 of the OCV.
- Make sure the resistance is within specification.
Specification: Refer to "Specifications"
Removal
- Turn the ignition switch OFF and disconnect the negative (-) battery cable.
- Disconnect the CVVT oil control valve connector (A).
- Loosen the installation bolt (B) and remove the valve from the engine. [Bank 1 / Intake]
[Bank 1/Exhaust]

Installation
|
|
- Install in the reverse order of removal. CVVT oil control valve bolt: 9.8 ~ 11.8 N·m
Test yourself
A quick Hyundai Sonata LF quiz: every answer comes with an explanation and a link to the manual page.
Was this page helpful?