Blower

Blower
1 – blower motor cooling tube;
2 – resistor block;
3 – air intake;
4 – intake door shaft;
5 – upper blower housing;
6 – lower blower housing;
7 – blower wheel;
8 – blower motor;
9 – blower motor cover.
Removal and installation
PROCEDURE
1. Remove the instrument panel.
2. Disconnect the connectors from the blower motor and the resistor block.
3. Remove the nuts and remove the evaporator unit.
4. Remove the 3 blower bracket nuts (or bolts).
5. Remove the blower unit.

6. Installation is performed in the reverse order of removal.
Removal
PROCEDURE

1. Disconnect the blower motor cooling tube.
2. Remove the three screws and remove the blower motor.

3. Release the clips securing the air intake to the upper blower housing.
4. Remove the air intake.

5. Using the blade of a flat-head screwdriver, release the six clips and separate the upper and lower blower housings.
6. Remove the two screws and remove the blower resistor.
7. Assembly is performed in the reverse order of disassembly.
Blower Motor Inspection
PROCEDURE
Using jumper wires, apply battery voltage to the blower motor terminals and connector. If the blower motor rotates, it is serviceable.