Engine Control System/Fuel System

WGT Electric Actuator Specifications

~1min read

Specification

[EWGA Position Sensor]

Position Output Voltage [V] Operating Angle [°] Rod Range [mm], Reference
Mechanical Closed End Stop Position (MCP) 4,8 0 0
Electrical Closed End Stop Position (ECP) 4.2 12 1,8
Electrical Open End Stop (EOP) 1 79 16
Mechanical Open End Stop Position (MOP) 0,5 90 18

[EWGA DC Motor]

Item Specification
Coil Resistance (Ω) 1,44–1,96 [21 °C]