Engine Control System/Fuel System

RCV Control Solenoid Valve Repair Procedures

8steps
~48min
3/5difficulty
0102030405011.89N·mlb·ft
Tightening torque found on this page
Done 0 of 8

Inspection

  1. Turn the ignition off.
  2. Disconnect the RCV connector.
  3. Measure the resistance between RCV terminals 1 and 2.
  4. Make sure the resistance is within specification.

    Specification: Refer to "Specifications"

Removal

  1. Turn the ignition switch OFF and disconnect the negative (-) battery terminal.
  2. Remove the air cleaner cover (A). (Refer to Engine Mechanical System - "Air Cleaner")
  3. Disconnect the RCV control solenoid valve connector (A) and the vapor hoses (B).
  4. Remove the RCV control solenoid valve (D) by loosening the mounting bolts (C).

Installation

  1. Install in the reverse order of removal. RCV control solenoid valve bracket mounting bolt: 9.8–11.8 N·m