Engine Control/Fuel System

CVVT Oil Control Valve (OCV) Repair procedures

9steps
~54min
2/5difficulty
0102030405011.89N·mlb·ft
Tightening torque found on this page
Done 0 of 9

Inspection

  1. Switch "OFF" the ignition.

  2. Disconnect the OCV connector.

  3. Measure resistance between the OCV terminals 1 and 2.

  4. Check that the resistance is within the specification.

    Specification: 9.4 ~ 10.4 Ω [20 °C]

Removal

[CVVT Oil Control Valve (Exhaust)]

  1. Switch "OFF" the ignition and disconnect the negative (-) battery terminal.

  2. OCV extension wiring connector (A).

  3. Release the wiring mounting bracket (B) after loosening the mounting bolt.

  4. Remove the mounting bolt (A), and then remove oil control valve & extension wiring (B) from the engine.

    CVVT oil control valve mounting bolt :

    9.8 - 11,8 N·m

  5. Disconnect the oil control valve (A) from the extension wiring (B).

Installation

  1. Install in the reverse order of removal.