Engine Control/Fuel System

Heated Oxygen Sensor (HO2S) Repair procedures

9steps
~64min
4/5difficulty
2special tools
02040608010049.136N·mlb·ft
Tightening torque found on this page
Done 0 of 9

Inspection

  1. Switch "OFF" the ignition.

  2. Disconnect the HO2S connector.

  3. Measure resistance between the HO2S terminals 4 and 5 [B1/S1].

    Specification: 2.5 - 4.0Ω [20 °C]

  4. Measure resistance between the HO2S terminals 3 and 4 [B1/S2].

    Specification: Approx. 9.0 Ω [21 °C]

  5. Check that the resistance is within the specification.

Removal

[Bank 1 / Sensor 1]

  1. Switch "OFF" the ignition and disconnect the negative (-) battery terminal.

  2. Disconnect the connector (A), and then remove the sensor (B).

    Heated oxygen sensor : 39.2 - 49 N·m

[Bank 1 / Sensor 2]

  1. Switch "OFF" the ignition and disconnect the negative (-) battery terminal.

  2. Disconnect the connector (A), and then remove the sensor (B).

    Heated oxygen sensor : 39.2 - 49 N·m

Installation

  1. Install in the reverse order of removal.