Body Exterior, Doors, Roof & Vehicle Security

B210e Starter Rly Off Circ

9steps
~54min
2/5difficulty
Done 0 of 9
DTC Description

Located in IPDM E/R, it runs the starter motor. The starter relay is turned ON by the BCM when ignition switch is in START position. IPDM E/R transmits the starter relay ON signal to BCM via CAN communication.

DTC DETECTION LOGIC

DTC No.CONSULT screen terms (Trouble diagnosis content)DTC Detection Condition
B210E

STARTER RLY OFF CIRC

(Starter relay off circuit)
Diagnosis condition When ignition switch ON.
Signal (terminal) —
Threshold

IPDM E/R detects that the relay is stuck at ON position even if the following conditions are met for about 1 second:

  • Starter control relay ON/OFF signal from BCM

  • Transmission range switch input

Diagnosis delay time —

POSSIBLE CAUSE

  • IPDM E/R

  • Harness or connector

FAIL-SAFE

—

DTC Confirmation Procedure

PERFORM DTC CONFIRMATION PROCEDURE

CONSULT

  1. Ignition switch ON under the following conditions and wait for at least 1 second:

    • CVT selector lever is in the P (Park) or N (Neutral) position.

    • Do not depress the brake pedal.

  2. Select “Self Diagnostic Result” mode of “IPDM E/R”.

  3. Check DTC.

Is DTC detected?

YES>>

Refer to Diagnosis Procedure.

NO>>

Inspection End.

Diagnosis Procedure

CHECK STARTER RELAY OUTPUT SIGNAL/CVT MODELS

  1. Ignition switch OFF.

  2. Disconnect BCM harness connector.

  3. Check voltage between BCM harness connector ground.

    (+)(–)Condition

    Voltage

    (Approx.)
    BCM
    ConnectorTerminalIgnition switchBrake pedalCVT selector lever
    M19 62 Ground ON Depressed P (Park) or N (Neutral) Battery voltage
    Other than above 0 V

Is the inspection result normal?

YES>>

Replace BCM. Refer to Removal and Installation.

NO>>

GO TO 2.

CHECK STARTER RELAY OUTPUT SIGNAL CIRCUIT

  1. Disconnect IPDM E/R harness connector.

  2. Check continuity between IPDM E/R harness connector and BCM harness connector.

    IPDM E/RBCMContinuity
    ConnectorTerminalConnectorTerminal
    E119 33 M19 62 Yes
  3. Check continuity between BCM harness connector and ground.

    IPDM E/R—Continuity
    ConnectorTerminal
    E119 33 Ground No

Is the inspection result normal?

YES>>

Replace IPDM E/R. Refer to Removal and Installation.

NO>>

Repair harness connector.