Body Exterior, Doors, Roof & Vehicle Security

B2608 Starter Relay

11steps
~66min
3/5difficulty
Done 0 of 11
DTC Description

DTC DETECTION LOGIC

DTC No.CONSULT screen terms (Trouble diagnosis content)DTC Detection Condition
B2608 STARTER RELAY (Starter relay) Diagnosis condition When ignition switch is ON.
Signal (terminal) —
Threshold BCM outputs starter motor relay OFF signal but BCM receives starter motor relay ON signal from IPDM E/R (CAN)
Diagnosis delay time —

POSSIBLE CAUSE

  • IPDM E/R

  • Harness or connectors

    (Starter relay circuit is open or shorted.)

  • Harness or connector

    (The CAN communication line is open or shorted.)

FAIL-SAFE

Inhibit engine cranking

DTC Confirmation Procedure

PERFORM DTC CONFIRMATION PROCEDURE

CONSULT

  1. Ignition switch ON under the following conditions to start engine:

    • Shift selector lever: In the P (Park) position.

    • Brake pedal: Depressed.

  2. Wait 1 second after engine started.

  3. Select “Self Diagnostic Result” mode of “BCM”.

  4. Check DTC.

Is DTC detected?

YES>>

Refer to Diagnosis Procedure.

NO>>

Inspection End.

Diagnosis Procedure

CHECK DTC OF IPDM E/R

CONSULT

Select “Self Diagnostic Result” mode of “IPDM E/R”.

Is DTC detected?

YES>>

Perform the trouble diagnosis related to the detected DTC. Refer to DTC Index.

NO>>

GO TO 2.

CHECK BCM POWER SUPPLY CIRCUIT

  1. Ignition switch ON.

  2. Check voltage between BCM harness connector and ground.

    (+)(–)Condition

    Voltage

    (Approx.)
    BCM
    ConnectorTerminal
    M19 62 Ground Selector lever N (Neutral) or P (Park) position Battery voltage
    Other than above 0 V

Is the inspection result normal?

YES>>

GO TO 4.

NO>>

GO TO 3.

CHECK STARTER RELAY CIRCUIT

  1. Ignition switch OFF.

  2. Disconnect IPDM E/R connector.

  3. Disconnect BCM connector.

  4. Check continuity between IPDM E/R harness connector and BCM harness connector.

    IPDM E/RBCMContinuity
    ConnectorTerminalConnectorTerminal
    E119 33 M19 62 Yes
  5. Check continuity between IPDM E/R harness connector and ground.

    IPDM E/R Ground Continuity
    Connector Terminal
    E119 33 No

Is the inspection result normal?

YES>>

Replace IPDM E/R. Refer to Removal and Installation.

NO>>

Repair or replace harness.

CHECK INTERMITTENT INCIDENT

Refer to Intermittent Incident.

>>

Inspection End.