Meters / Gauges / Display

Customizable Parameters

~1min read

CUSTOMIZABLE PARAMETERS

CUSTOMIZE GAUGE AND METER SYSTEM

(a) Customization Using the Techstream.

(1) Connect the Techstream to the DLC3.

(2) Turn the ignition switch ON.

(3) Turn on the Techstream.

(4) Select the following menus: Customize Setting / Warning or Display.

(5) Select the setting by referring to the table below.

NOTICE:

Be sure to record the current settings before customizing.

Display

Tester display

Description

Default setting

Setting

ECU

ECO Drive Indicator Zone

ECO Drive Indicator Zone change function

ON

0 : OFF, 1 : ON

Combination meter assembly

ECO Drive Indicator Light

Function to change the ECO Drive Indicator Light*1

ON

0 : OFF, 1 : ON

Combination meter assembly

ODO Display Time After IG OFF Setting

Function that changes the ODO display duration after the ignition switch is turned OFF

30s

00: 30s,01: 60s,10: 600s, 11: OFF

Combination meter assembly

Alarm

Tester display

Description

Default setting

Setting

ECU

Flasher Sound Tone Setting

Function that changes the turn signal sound tone

Tone 1

00: tone 1, 01: tone 2, 10: tone 3

Combination meter assembly

Lane Change Flashing Times Setting

Function to change the flashing time of the lane change indicator

3

000:OFF,001:3 010:4 011:5 100:6 101:7

Combination meter assembly