Engine Control System/Fuel System

Repair Procedures - Purge Control Solenoid Valve (PCSV)

8steps
~48min
2/5difficulty
0102030405011.89N·mlb·ft
Tightening torque found on this page
Done 0 of 8

Inspection

  1. Turn the ignition off.
  2. Disconnect the PCSV connector.
  3. Measure the resistance between terminals 1 and 2 of the PCSV.
  4. Make sure the resistance is within specification.

    Specification: Refer to "Specifications"

Removal

  1. Turn the ignition switch OFF and disconnect the negative (-) battery cable.
  2. Disconnect the purge control solenoid valve connector (A).
  3. Disconnect the vapor hoses (B) from the purge control solenoid valve.
  4. Remove the valve from the bracket.

Installation

  • Install the component with the specified torque.
  • Be careful not to drop the component, as internal damage may occur. If dropped, inspect it before installation.
  • Do not apply oil or grease to the hose ends when connecting the PCSV hose.
  • Be careful not to allow foreign material to enter the valve.
  1. To install, perform the removal procedure in reverse order. Purge control solenoid valve bracket bolt: 7.8 ~ 11.8 N·m

Test yourself