Theft Deterrent / Keyless Entry

Horn circuit

~1min read

DESCRIPTION

When the anti-theft system changes from the armed state to the alarm sounding state, the main body ECU (multiplex network body ECU) outputs a signal to sound the security horn at 0.4-second intervals.

WIRING DIAGRAM

PRECAUTION / NOTICE / HINT

NOTICE:

  • Before replacing the main body ECU (multiplex network body ECU), refer to the REGISTRATION section*1.

    Click here

    *1: with Smart Key System

  • Check the fuses for the circuits related to this system before performing the following procedure.

PROCEDURE

  1. INSPECT HORNS

(a) Press the horn switch and check that the horns sound.

Result:

Result

Proceed to

Horns sound

A

Horns do not sound

B

B

GO TO HORN SYSTEM

A
  1. INSPECT INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY

(a) Remove the main body ECU (multiplex network body ECU).

Click here

*a

Component without wire harness connected

(instrument panel junction block assembly)

-

-

(b) Disconnect the connector from the instrument panel junction block assembly.

(c) Measure the resistance according to the value(s) in the table below.

Standard resistance:

Tester Connection

Condition

Specified Condition

3F-27 - MB-28 (HORN)

Always

Below 1 Ω

OK

REPLACE MAIN BODY ECU (MULTIPLEX NETWORK BODY ECU)

NG

REPLACE INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY