Engine/Fuel Control System

PURGE CONTROL SOLENOID VALVE (PCSV) Repair Procedures

9steps
~54min
2/5difficulty
0102030405011.89N·mlb·ft
Tightening torque found on this page
Done 0 of 9

Inspection

  1. Turn the ignition switch to the OFF position.
  2. Disconnect the PCSV connector.
  3. Measure the resistance between terminals 1 and 2 of the PCSV.
  4. Check that the resistance is within specification.

    Specification: 22.0 ~ 26.0 [20 °C]

DEPOSIT

  1. Turn the ignition switch to the OFF position and disconnect the negative (-) battery terminal.
  2. Remove the air cleaner. (Refer to Engine Mechanical System - "Air Cleaner")
  3. Disconnect the connector from the purge control solenoid valve.
  4. Disconnect the evaporator hoses (A) from the purge control solenoid valve.
  5. Remove the PCSV (B) by removing the bolt.

REMEDY

  1. To install, perform the removal procedure in reverse. Purge control solenoid valve bracket bolt tightening torque: 9.8 - 11.8 N·m

Test yourself