Data List / Active Test
DATA LIST / ACTIVE TEST
DATA LIST
NOTICE:
In the table below, the values listed under "Normal Condition" are reference values. Do not determine whether a part is faulty based only on these reference values.
HINT:
The Techstream Data List allows you to read the values or status of switches, sensors, actuators and other components without removing any parts. This non-intrusive check can be very useful, since intermittent conditions or signals can be identified before parts or wiring are moved. Reading the Data List during troubleshooting saves time in diagnosis.
(a) Connect the Techstream to the DLC3.
(b) Turn the ignition switch to ON.
(c) Turn on the Techstream.
(d) Select the following menu items: Body Electrical / Air Conditioner / Data List.
(e) Read the Data List by following the instructions on the Techstream.
Body Electrical > Air Conditioner > Data ListTester display | Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
Room Temperature Sensor |
Cooler Thermistor (Room Temperature Sensor) |
Min.: -6,50 °C Max.: 57 °C |
Actual Room Temperature Displayed |
- |
Ambient Temp Sensor |
Thermistor Assembly |
Min.: -23,30 °C Max.: 66 °C |
Actual Ambient Temperature Displayed |
- |
Adjusted Ambient Temp |
Adjusted Ambient Temperature |
Min.: -30,80 °C Max.: 51 °C |
- |
- |
Evaporator Fin Thermistor |
No. 1 Cooler Thermistor (Evaporator Temperature Sensor) |
Min.: -29,70 °C Max.: 60 °C |
Actual Evaporator Temperature Displayed |
- |
Evaporator Target Temp |
Evaporator Target Temperature |
Min.: -327,68 °C Max.: 328 °C |
Evaporator Target Temperature Displayed |
- |
Solar Sensor (D Side) |
Driver Side Solar Sensor |
Min.: 0 Max.: 255 |
The driver side solar sensor value increases as light intensity increases |
- |
Solar Sensor (P Side) |
Front Passenger Side Solar Sensor |
Min.: 0 Max.: 255 |
The front passenger side solar sensor value increases as light intensity increases |
- |
Regulator Control Current |
Control Solenoid Valve Current |
Min.: 0 A Max.: 0.997 A |
Value varies between 0 A and 0.997 A depending on solenoid valve operation |
- |
Electric Heater Count |
Maximum Electric Heater Operation Level |
Min.: 0 Max.: 3 |
Maximum possible electric heater operation displayed |
*1 |
Electric Heater Active Level |
Actual electric heater operation level |
Min.: 0 Max.: 3 |
Displayed actual electric heater operation level |
*1 |
Shift Set Temperature |
Set Temperature Change |
2C decr, 1C decr, Normal, 1C incr, 2C incr |
Customized display value |
- |
Compressor Mode |
Compressor Mode |
Auto or Manual |
Customized display value |
- |
Evaporator Control |
Evaporator Control |
Auto or Manual |
Customized display value |
- |
Fan Speed Increment Control |
Fan Speed Scroll Control |
Slow, Normal, Fast |
Customized display value |
- |
Foot/DEF Auto Mode |
Foot/DEF Auto Mode |
ON or OFF |
Customized display value |
- |
Foot/DEF Auto Blow Up |
Foot/DEF Auto Blower Increase |
ON or OFF |
Customized display value |
- |
A/C Cutoff Signal |
A/C Cutoff Control Signal |
ON or OFF |
A/C Switch ON: OFF A/C Switch OFF: ON |
- |
Ion Generate Control |
Ion Generator Assembly |
ON or OFF |
Customized display value |
*2 |
Refrigerant Gas Type |
Refrigerant Gas Type |
R134a or 1234yf |
Displays refrigerant gas type |
- |
Set Temperature (D Side) |
Driver Side Set Temperature |
Min.: MAX COLD Max.: MAX HOT |
Driver side set temperature is displayed |
- |
Set Temperature (P Side) |
Front Passenger Side Set Temperature |
Min.: MAX COLD Max.: MAX HOT |
Front passenger side set temperature displayed |
- |
Outside Air Mode Auto Switch Function |
Fresh Air Mode Auto Switch Function |
ON or OFF |
Customized display value |
- |
Number of Trouble Codes |
Number of DTCs |
Min.: 0 Max.: 255 |
Number of DTCs displayed |
- |
Upper Air Mix Target Position (Driver Side) |
Target Position of Air Conditioning Radiator Damper Servo Subassembly No. 1 (Upper Air Mix, Driver Side) |
Min.: 0 Max.: 100 |
|
- |
Upper Air Mix Current Position (Driver Side) |
Current Position of Air Conditioning Radiator Damper Servo Subassembly No. 1 (Upper Air Mix, Driver Side) |
Min.: 0 Max.: 100 |
|
- |
Lower Air Mix Target Position (Driver Side) |
Target Position of Air Conditioning Radiator Damper Servo Subassembly No. 1 (Lower Air Mix, Driver Side) |
Min.: 0 Max.: 100 |
|
- |
Lower Air Mix Current Position (Driver Side) |
Current Position of Air Conditioning Radiator Damper Servo Subassembly No. 1 (Lower Air Mix, Driver Side) |
Min.: 0 Max.: 100 |
|
- |
Upper Air Mix Target Position (Passenger Side) |
Target Position of Air Conditioning Radiator Damper Servo Subassembly No. 1 (Upper Air Mix, Front Passenger Side) |
Min.: 0 Max.: 100 |
|
- |
Upper Air Mix Current Position (Passenger Side) |
Current Position of Air Conditioning Radiator Damper Servo Subassembly No. 1 (Upper Air Mix, Front Passenger Side) |
Min.: 0 Max.: 100 |
|
- |
Lower Air Mix Target Position (Passenger Side) |
Target Position of Air Conditioning Radiator Damper Servo Subassembly No. 1 (Lower Air Mix, Front Passenger Side) |
Min.: 0 Max.: 100 |
|
- |
Lower Air Mix Current Position (Passenger Side) |
Current Position of Air Conditioning Radiator Damper Servo Subassembly No. 1 (Lower Air Mix, Front Passenger Side) |
Min.: 0 Max.: 100 |
|
- |
Front Air Outlet Target Position |
Target Position of Air Conditioning Radiator Damper Servo Subassembly No. 2 (Mode Switching) |
Min.: 0 Max.: 100 |
|
- |
Front Air Outlet Current Position |
Actual Position of Air Conditioning Radiator Damper Servo Subassembly No. 2 (Mode Switching) |
Min.: 0 Max.: 100 |
|
- |
Air Inlet Target Position |
Target Position of Blower Damper Servo Subassembly No. 1 |
Min.: 0 Max.: 100 |
|
- |
Air Inlet Current Position |
Current Position of Blower Damper Servo Subassembly No. 1 |
Min.: 0 Max.: 100 |
|
- |
Engine Coolant Temperature |
Engine coolant temperature sensor |
Min.: 0.5 °C Max.: 128 °C |
Actual Engine Coolant Temperature Displayed |
- |
Regulator Pressure Sensor |
Air Conditioning Pressure Sensor |
Min.: 0 kPa Max.: 3,760 kPa |
Actual Refrigerant Pressure Displayed |
- |
Air Outlet Target Temperature (Driver Side) |
Air Outlet Target Temperature (Driver Side) |
Min.: -327,68 °C Max.: 328 °C |
Actual Display of Air Outlet Target Temperature (Driver Side) |
- |
Air Outlet Target Temperature (Passenger Side) |
Air Outlet Target Temperature (Front Passenger Side) |
Min.: -327,68 °C Max.: 328 °C |
Actual Display of Air Outlet Target Temperature (Front Passenger Side) |
- |
- *1: with PTC heater
- *2: With ion generator
ACTIVE TEST
HINT:
Using the Techstream to perform Active Tests allows relays, VSVs, actuators and other items to be operated without removing parts. This non-intrusive functional check can be very useful, because intermittent operation can be identified before parts or wiring are moved. Performing Active Tests at the start of troubleshooting saves time during diagnosis. Data List information can be displayed during Active Tests.
(a) Connect the Techstream to the DLC3.
(b) Turn the ignition switch to ON.
(c) Turn on the Techstream.
(d) Select the following menu items: Body Electrical / Air Conditioner / Active Test.
(e) Perform the Active Test by following the Techstream instructions.
Body Electrical > Air Conditioner > Active TestTester display | Item | Control Range | Diagnostic Note |
|---|---|---|---|
Magnetic Clutch Relay |
Air Conditioning System Operation |
OFF or ON |
- |
Heater Active Level |
Quick heating assembly |
Min.: 0 Max.: 3 |
*1 |
Ion Generator |
Ion Generator Assembly |
OFF or ON |
*2 |
Blower Motor |
Blower motor sub-assembly with fan |
Min.: 0 Max.: 100 |
Operates Between 0 à 100 % |
Air Inlet |
No. 1 Blower Damper Servo Subassembly (Outside Air/Recirculated Air) |
Min.: 0 Max.: 100 |
Operates Between 0 à 100 % |
Air Outlet (Front) |
No. 2 Air Conditioning Radiator Door Servo Sub-assembly (Mode Switching) |
Min.: 0 Max.: 100 |
Operates Between 0 à 100 % |
Upper Air Mix (Driver Side) |
No. 1 Air Conditioning Radiator Door Servo Sub-assembly (Upper Air Mix, Driver Side) |
Min.: 0 Max.: 100 |
Operates Between 0 à 100 % |
Lower Air Mix (Driver Side) |
Air Conditioning Radiator No. 1 Damper Servo Assembly (lower air mix, driver side) |
Min.: 0 Max.: 100 |
Operates Between 0 à 100 % |
Upper Air Mix (Passenger Side) |
No. 1 Air Conditioning Radiator Door Servo Sub-assembly (Upper Air Mix, Front Passenger Side) |
Min.: 0 Max.: 100 |
Operates Between 0 à 100 % |
Lower Air Mix (Passenger Side) |
Air Conditioning Radiator No. 1 Damper Servo Assembly (lower air mix, front passenger side) |
Min.: 0 Max.: 100 |
Operates Between 0 à 100 % |
- *1: with PTC heater
- *2: With ion generator