B26fd Shft Lck Slnoid Insid F/b Mlfnc
DTC DETECTION LOGIC
| DTC No. | CONSULT screen terms (Trouble diagnosis content) | DTC Detection Condition | |
|---|---|---|---|
| B26FD | SHFT LCK SLNOID INSID F/B MLFNC (Shift lock solenoid inside feedback malfunction) |
Diagnosis condition | When ignition switch is ON. |
| Signal (terminal) | BCM terminals 108 | ||
| Threshold | BCM shift lock solenoid output control is OFF, but shift lock solenoid output feedback is ON | ||
| Diagnosis delay time | 1 second | ||
POSSIBLE CAUSE
Shift lock solenoid
Harness or connector
Shift lock solenoid circuit is open or shorted
Stop lamp switch
FAIL-SAFE
—
PERFORM DTC CONFIRMATION PROCEDURE
CONSULT
Ignition switch ON.
Select “Self Diagnostic Result” mode of “BCM”.
Is DTC detected?
YES>>Refer to DTC Diagnosis Procedure.
NO>>Shift lock solenoid is OK.
CHECK POWER SOURCE (STOP LAMP SWITCH)
Ignition switch OFF.
Disconnect stop lamp switch connector.
Check voltage between stop lamp switch connector and ground.
Stop lamp switch Ground Voltage
(Approx.)Connector Terminal E38 1 Battery voltage
Is the inspection result normal?
YES>>GO TO 2.
NO>>Check the following:
Harness for short or open between fuse block (J/B) and stop lamp switch
10A fuse (No. 10, located in fuse block [J/B])
CHECK STOP LAMP SWITCH
Check stop lamp switch. Refer to Component Inspection.
Is the inspection result normal?
YES>>GO TO 3.
NO>>Replace stop lamp switch. Refer to Exploded View.
CHECK GROUND CIRCUIT (BCM)
Disconnect BCM connector.
Check continuity between BCM connector and ground.
BCM Ground Continuity Connector Terminal M81 134 Yes 143
Is the inspection result normal?
YES>>GO TO 4.
NO>>Repair or replace damaged parts.
CHECK HARNESS BETWEEN BCM AND STOP LAMP SWITCH FOR OPEN
Check continuity between BCM connector and stop lamp switch connector.
| BCM | Stop lamp switch | Continuity | ||
| Connector | Terminal | Connector | Terminal | |
| M18 | 27 | E38 | 2 | Yes |
Is the inspection result normal?
YES>>GO TO 5.
NO>>Repair or replace damaged parts.
CHECK HARNESS BETWEEN BCM AND STOP LAMP SWITCH FOR SHORT CIRCUIT
Check continuity between BCM connector and ground.
| BCM | Ground | Continuity | |
| Connector | Terminal | ||
| M18 | 27 | No | |
Is the inspection result normal?
YES>>GO TO 6.
NO>>Repair or replace damaged parts.
CHECK HARNESS BETWEEN BCM AND CVT SHIFT SELECTOR FOR OPEN
Disconnect CVT shift selector connector.
Check continuity between BCM and CVT shift selector.
BCM CVT shift selector Continuity Connector Terminal Connector Terminal M80 108 M78 3 Yes
Is the inspection result normal?
YES>>GO TO 7.
NO>>Repair or replace damaged parts.
CHECK HARNESS BETWEEN BCM AND CVT SHIFT SELECTOR FOR SHORT CIRCUIT
Check continuity between BCM and ground.
| BCM | Ground | Continuity | |
| Connector | Terminal | ||
| M80 | 108 | No | |
Is the inspection result normal?
YES>>GO TO 8.
NO>>Repair or replace damaged parts.
CHECK GROUND CIRCUIT (CVT SHIFT SELECTOR)
Check continuity between CVT shift selector and ground.
| CVT shift selector | Ground | Continuity | |
| Connector | Terminal | ||
| M78 | 4 | Yes | |
Is the inspection result normal?
YES>>Replace shift lock solenoid. Refer to Exploded View.
NO>>Repair or replace damaged parts.